Measuring Visual Function in Age-Related Macular Degeneration with Frequency-Doubling (Matrix) Perimetry

被引:12
作者
Anderson, Andrew John [1 ]
Johnson, Chris A. [2 ]
Werner, John S. [3 ]
机构
[1] Univ Melbourne, Dept Optometry & Vis Sci, Parkville, Vic 3010, Australia
[2] Univ Iowa Hosp & Clin, Dept Ophthalmol & Vis Sci, Iowa City, IA 52242 USA
[3] Univ Calif Davis, Dept Ophthalmol & Vis Sci, Sacramento, CA 95817 USA
关键词
age-related macular degeneration; automated perimetry; visual field; psychophysics; frequency doubling; visual acuity; contrast; STANDARD AUTOMATED PERIMETRY; TECHNOLOGY PERIMETRY; FLICKER SENSITIVITY; CATARACT-EXTRACTION; HUMPHREY MATRIX; THRESHOLD; GLAUCOMA; FIELD; MACULOPATHY; VARIABILITY;
D O I
10.1097/OPX.0b013e31821861bd
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To determine the agreement between the Humphrey Matrix perimeter 10-2 test and the 10-2 Humphrey Field Analyzer (HFA) test when assessing visual function in patients with age-related macular degeneration (AMD). Methods. Forty-two eyes of 42 subjects with AMD (average 75.0 years, SD = 6.2: median visual acuity in logarithm of the minimum angle of resolution of 0.26, range, -0.12 to 1.04) were evaluated with the Matrix and HFA 10-2 visual field tests. Mean deviation (MD), pattern standard deviation, and test time were recorded. We calculated spatial concordance of individual test locations, being the proportion of spatially agreeing locations with identical classification (normal vs. abnormal, p < 5%) on the pattern deviation plot. As multiple HFA stimuli overlapped with some Matrix locations, several criteria for grouping HFA data into locations were investigated. Results. Both MD and pattern standard deviation were significantly correlated for the two devices (r(2) = 0.79 and r(2) = 0.80, respectively, p < 0.0001). Using our standard criterion for abnormal HFA locations (>= 50% stimuli abnormal), the median spatial concordance was 0.76, with 95% of tests giving a concordance of >= 0.59. A small, but significant, increase in concordance occurred when a stricter criterion (all stimuli abnormal at a location) was applied. Median fixation loss percentages were 7 and 0% for the HFA and Matrix, respectively. Visual acuity in logarithm of the minimum angle of resolution showed modest correlations with both defect depth (HFA MD: r(2) = 0.39, p < 0.0001) and size of defect (number of abnormal points on the HFA: r(2) = 0.24, p < 0.0001). Conclusions. Using a simple metric to calculate spatial concordance, the Matrix 10-2 test quantifies the spatial extent of significant depression of the central visual fields in AMD in a manner similar to the HFA 10-2. The spatial extent and depth of central visual field loss in AMD are only modestly predicted by visual acuity measurements. (Optom Vis Sci 2011; 88: 806-815)
引用
收藏
页码:806 / 815
页数:10
相关论文
共 46 条
[1]   Anatomy of a supergroup: Does a criterion of normal perimetric performance generate a supernormal population? [J].
Anderson, AJ ;
Johnson, CA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (11) :5043-5048
[2]   Utility of a dynamic termination criterion in the ZEST adaptive threshold method [J].
Anderson, AJ .
VISION RESEARCH, 2003, 43 (02) :165-170
[3]   Multiple processes mediate flicker sensitivity [J].
Anderson, AJ ;
Vingrys, AJ .
VISION RESEARCH, 2001, 41 (19) :2449-2455
[4]   Interactions between flicker thresholds and luminance pedestals [J].
Anderson, AJ ;
Vingrys, AJ .
VISION RESEARCH, 2000, 40 (19) :2579-2588
[5]   Characteristics of the normative database for the Humphrey Matrix perimeter [J].
Anderson, AJ ;
Johnson, CA ;
Fingeret, M ;
Keltner, JL ;
Spry, PGD ;
Wall, M ;
Werner, JS .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) :1540-1548
[6]  
Anderson Andrew J, 2003, Ophthalmol Clin North Am, V16, P213, DOI 10.1016/S0896-1549(03)00011-7
[7]  
Anderson D.R., 1999, Automated static perimetry, V2nd
[8]  
[Anonymous], 1984, Prog Retinal Res, DOI [DOI 10.1016/0278-4327(84)90011-7, 10.1016/0278-4327(84)90011-7]
[9]   Signal/Noise Analysis to Compare Tests for Measuring Visual Field Loss and Its Progression [J].
Artes, Paul H. ;
Chauhan, Balwantray C. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (10) :4700-4708
[10]   Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma [J].
Artes, PH ;
Hutchison, DM ;
Nicolela, MT ;
LeBlanc, RP ;
Chauhan, BC .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2451-2457