New Approach for Optimal Location and Parameters Setting of UPFC for Enhancing Power Systems Stability under Contingency Analysis

被引:15
作者
Zahid, Muhammad [1 ]
Chen, Jinfu [1 ]
Li, Yinhong [1 ]
Duan, Xianzhong [1 ]
Lei, Qi [1 ]
Bo, Wang [2 ]
Mohy-ud-Din, Ghulam [3 ,4 ]
Waqar, Asad [5 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
[2] State Grid Hubei Elect Power Co Technol, Project 52153816000Y, Wuhan 430074, Peoples R China
[3] Univ Wollongong, Sch Elect Comp & Telecommun Engn, Wollongong, NSW 2522, Australia
[4] COMSATS Inst Informat Technol, Dept Elect Engn, Wah Cantt 47040, Pakistan
[5] Bahria Univ, Dept Elect Engn, Islamabad 44000, Pakistan
来源
ENERGIES | 2017年 / 10卷 / 11期
关键词
optimal power flow; Artificial Algae Algorithm (AAA); Unified Power Flow Controller (UPFC); contingency; Performance Parameter (PP); ARTIFICIAL ALGAE ALGORITHM; OPTIMAL PLACEMENT; FACTS DEVICES; DYNAMIC STABILITY; FLOW; OPTIMIZATION; ENHANCEMENT; IMPROVE;
D O I
10.3390/en10111738
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Operation of power system within specified limits of voltage and frequency are the major concerns in power system stability studies. As power system is always prone to disturbances, which consequently affect the voltage instability and optimal power flow, and therefore risks the power systems stability and security. In this paper, a novel technique based on the "Artificial Algae Algorithm" (AAA) is introduced, to identify the optimal location and the parameters setting of Unified Power Flow Controller (UPFC) under N-1 contingency criterion. In the first part, we have carried out a contingency operation and ranking process for the most parlous lines outage contingencies while taking the transmission lines overloading (NOLL) and voltage violation of buses (NVVB) as a performance parameter (PP = NOLL + NVVB). As UPFC possesses too much prohibitive cost and larger size, its optimal location and size must be identified before the actual deployment. In the second part, we have applied a novel AAA technique to identify the optimal location and parameters setting of UPFC under the discovered contingencies. The simulations have been executed on IEEE 14 bus and 30 bus networks. The results reveals that the location of UPFC is significantly optimized using AAA technique, which has improved the stability and security of the power system by curtailing the overloaded transmission lines and limiting the voltage violations of buses.
引用
收藏
页数:23
相关论文
共 33 条
  • [1] Acha C.R. F.-E. Enrique., 2004, FACTS MODELLING SIMU
  • [2] Optimal siting and sizing of UPFC using evolutionary algorithms
    Alamelu, Somasundaram
    Baskar, S.
    Babulal, C. K.
    Jeyadevi, S.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 69 : 222 - 231
  • [3] [Anonymous], 2011, Modern power system analysis
  • [4] AUTOMATIC CONTINGENCY SELECTION
    EJEBE, GC
    WOLLENBERG, BF
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (01): : 97 - 109
  • [5] Exposito A.G., 2016, Electric energy systems: analysis and operation
  • [6] INVESTIGATION OF LOAD-FLOW PROBLEM
    FRERIS, LL
    SASSON, AM
    [J]. PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1968, 115 (10): : 1459 - &
  • [7] A comprehensive Newton-Raphson UPFC model for the quadratic power flow solution of practical power networks
    Fuerte-Esquivel, CR
    Acha, E
    Ambriz-Pérez, H
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (01) : 102 - 109
  • [8] Newton-type algorithm for the control of power flow in electrical power networks
    FuerteEsquivel, CR
    Acha, E
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1997, 12 (04) : 1474 - 1480
  • [9] UNIFIED POWER-FLOW CONTROL CONCEPT FOR FLEXIBLE AC TRANSMISSION-SYSTEMS
    GYUGYI, L
    [J]. IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1992, 139 (04) : 323 - 331
  • [10] Application of HGSO to security based optimal placement and parameter setting of UPFC
    Hagh, Mehrdad Tarafdar
    Alipour, Manijeh
    Teimourzadeh, Saeed
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 86 : 873 - 885