Three-dimensional hydrogel cultures for modeling changes in tissue impedance around microfabricated neural probes

被引:30
作者
Frampton, J. P. [1 ]
Hynd, M. R. [2 ]
Williams, J. C. [3 ]
Shuler, M. L. [4 ]
Shain, W. [1 ,2 ]
机构
[1] SUNY Albany, Sch Publ Hlth, Dept Biomed Sci, Albany, NY 12222 USA
[2] Wadsworth Ctr, Albany, NY USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
[4] Cornell Univ, Dept Biomed Engn, Ithaca, NY USA
关键词
D O I
10.1088/1741-2560/4/4/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One limitation to the use of neuroprosthestic devices for chronic application, in the treatment of disease, is the reactive cell responses that occur surrounding the device after insertion. These cell and tissue responses result in increases in device impedance and failure of the device to interact with target populations of neurons. However, few tools are available to assess which components of the reactive response contribute most to changes in tissue impedance. An in vitro culture system has been developed that is capable of assessing individual components of the reactive response. The system utilizes alginate cell encapsulation to construct three-dimensional architectures that approach the cell densities found in rat cortex. The system was constructed around neuroNexus acute probes with on-board circuitry capable of monitoring the electrical properties of the surrounding tissue. This study demonstrates the utility of the system by demonstrating that differences in cell density within the three-dimensional alginate constructs result in differences in resistance and capacitance as measured by electrochemical impedance spectroscopy. We propose that this system can be used to model components of the reactive responses in brain tissue, and that the measurements recorded in vitro are comparable to measurements recorded in vivo.
引用
收藏
页码:399 / 409
页数:11
相关论文
共 37 条
[1]   Label-free, real-time monitoring of IgE-mediated mast cell activation on microelectronic cell sensor arrays [J].
Abassi, YA ;
Jackson, JA ;
Zhu, J ;
O'Connell, J ;
Wang, XB ;
Xu, X .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 292 (1-2) :195-205
[2]   Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays [J].
Biran, R ;
Martin, DC ;
Tresco, PA .
EXPERIMENTAL NEUROLOGY, 2005, 195 (01) :115-126
[3]   Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion [J].
Bjornsson, C. S. ;
Oh, S. J. ;
Al-Kofahi, Y. A. ;
Lim, Y. J. ;
Smith, K. L. ;
Turner, J. N. ;
De, S. ;
Roysam, B. ;
Shain, W. ;
Kim, S. J. .
JOURNAL OF NEURAL ENGINEERING, 2006, 3 (03) :196-207
[4]   Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy [J].
Buitenweg, JR ;
Rutten, WLC ;
Willems, WPA ;
van Nieuwkasteele, JW .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (05) :630-637
[5]   Patient-speciftic analysis of the volume of tissue activated during deep brain stimulation [J].
Butson, Christopher R. ;
Cooper, Scott E. ;
Henderson, Jaimie M. ;
McIntyre, Cameron C. .
NEUROIMAGE, 2007, 34 (02) :661-670
[6]   Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulation [J].
Butson, CR ;
McIntyre, CC .
CLINICAL NEUROPHYSIOLOGY, 2005, 116 (10) :2490-2500
[7]   Large-scale recording of neuronal ensembles [J].
Buzsáki, G .
NATURE NEUROSCIENCE, 2004, 7 (05) :446-451
[8]   Using multi-neuron population recordings for neural prosthetics [J].
Chapin, JK .
NATURE NEUROSCIENCE, 2004, 7 (05) :452-455
[9]   Connecting cortex to machines: recent advances in brain interfaces [J].
Donoghue, JP .
NATURE NEUROSCIENCE, 2002, 5 (Suppl 11) :1085-1088
[10]   Impedance characterization and modeling of electrodes for biomedical applications [J].
Franks, W ;
Schenker, I ;
Schmutz, P ;
Hierlemann, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (07) :1295-1302