Crescent artifacts in cone-beam CT

被引:10
|
作者
Giles, William [1 ]
Bowsher, James [1 ]
Li, Hao
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Med Phys Grad Program, Durham, NC 27710 USA
关键词
crescent artifact; cone-beam CT; image reconstruction; COMPUTED-TOMOGRAPHY; SCATTER;
D O I
10.1118/1.3567508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In image-guided radiation therapy, cone-beam CT has been adopted for three-dimensional target localization in the treatment room. In many of these cone-beam CT images, dark and light crescent artifacts can be seen. This study investigates potential causes of this artifact and a technique for mitigating the crescents. Methods: Three deviations from an ideal geometry were simulated to assess their ability to cause crescent artifacts: Bowtie filter sag, x-ray tube sag, and x-ray tube rotation. The magnitudes of these deviations were estimated by matching shifts in simulated projections to those observed with clinical systems. To correct the artifacts, angle-dependent blank projections were acquired and incorporated into image reconstruction. The degree of artifact reduction was evaluated with varying numbers (1-380) of blank projections. Scanner-acquired phantom and patient studies were conducted to demonstrate the effectiveness of the proposed correction method. Results: All three investigated causes of the crescent artifact introduced similar mismodeling of the acquired projections and similar crescent artifacts. The deviations required for these artifacts were in the range of 0.5-5 mm or 0.1. RMS error is reduced from 8.91 x 10(-4) to 5.25 x 10(-7) for 1-380 blank projections over a 200 scan angle. In the patient and phantom studies, reconstructions that utilized 380 blank projections largely mitigated the crescent artifacts. Conclusions: Small deviations from an ideal geometry can result in crescent artifacts due to steep gradients in the bowtie filter. Angle-dependent blank projections can largely alleviate the artifacts. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3567508]
引用
收藏
页码:2116 / 2121
页数:6
相关论文
共 50 条
  • [41] Beam characteristics and radiation output of a kilovoltage cone-beam CT
    Ding, George X.
    Coffey, Charles W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17): : 5231 - 5248
  • [42] A model-based scatter artifacts correction for cone beam CT
    Zhao, Wei
    Vernekohl, Don
    Zhu, Jun
    Wang, Luyao
    Xing, Lei
    MEDICAL PHYSICS, 2016, 43 (04) : 1736 - 1753
  • [43] Moving Beam-Blocker-Based Low-Dose Cone-Beam CT
    Lee, Taewon
    Lee, Changwoo
    Baek, Jongduk
    Cho, Seungryong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (05) : 2540 - 2549
  • [44] A review of cone-beam CT applications for adaptive radiotherapy of prostate cancer
    Posiewnik, M.
    Piotrowski, T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 13 - 21
  • [45] Interfraction variation in prostate cancer - analysis of 11726 cone-beam CT
    Dolezel, Martin
    Slezak, Peter
    Odrazka, Karel
    Vanasek, Jaroslav
    Hlavka, Ales
    Ulrych, Vit
    Stuk, Jan
    Waczulikova, Iveta
    Hartmann, Igor
    JOURNAL OF BUON, 2015, 20 (04): : 1081 - 1087
  • [46] Task-driven image acquisition and reconstruction in cone-beam CT
    Gang, Grace J.
    Stayman, J. Webster
    Ehtiati, Tina
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : 3129 - 3150
  • [47] BPF-Type Reconstruction for Dual Helical Cone-Beam CT
    Zeng, Li
    Zou, Xiaobing
    CURRENT MEDICAL IMAGING, 2011, 7 (02) : 125 - 135
  • [48] Evaluation of an Analytic Reconstruction Method as a Platform for Spectral Cone-Beam CT
    Kong, Huihua
    Liu, Rui
    Pan, Jinxiao
    Yu, Hengyong
    IEEE ACCESS, 2018, 6 : 21314 - 21323
  • [49] kV Cone-Beam CT-Based IGRT A Clinical Review
    Boda-Heggemann, Judit
    Lohr, Frank
    Wenz, Frederik
    Flentje, Michael
    Guckenberger, Matthias
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (05) : 284 - 291
  • [50] Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT
    Lazos, Dimitrios
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2010, 37 (10) : 5456 - 5470