Crescent artifacts in cone-beam CT

被引:10
|
作者
Giles, William [1 ]
Bowsher, James [1 ]
Li, Hao
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Med Phys Grad Program, Durham, NC 27710 USA
关键词
crescent artifact; cone-beam CT; image reconstruction; COMPUTED-TOMOGRAPHY; SCATTER;
D O I
10.1118/1.3567508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In image-guided radiation therapy, cone-beam CT has been adopted for three-dimensional target localization in the treatment room. In many of these cone-beam CT images, dark and light crescent artifacts can be seen. This study investigates potential causes of this artifact and a technique for mitigating the crescents. Methods: Three deviations from an ideal geometry were simulated to assess their ability to cause crescent artifacts: Bowtie filter sag, x-ray tube sag, and x-ray tube rotation. The magnitudes of these deviations were estimated by matching shifts in simulated projections to those observed with clinical systems. To correct the artifacts, angle-dependent blank projections were acquired and incorporated into image reconstruction. The degree of artifact reduction was evaluated with varying numbers (1-380) of blank projections. Scanner-acquired phantom and patient studies were conducted to demonstrate the effectiveness of the proposed correction method. Results: All three investigated causes of the crescent artifact introduced similar mismodeling of the acquired projections and similar crescent artifacts. The deviations required for these artifacts were in the range of 0.5-5 mm or 0.1. RMS error is reduced from 8.91 x 10(-4) to 5.25 x 10(-7) for 1-380 blank projections over a 200 scan angle. In the patient and phantom studies, reconstructions that utilized 380 blank projections largely mitigated the crescent artifacts. Conclusions: Small deviations from an ideal geometry can result in crescent artifacts due to steep gradients in the bowtie filter. Angle-dependent blank projections can largely alleviate the artifacts. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3567508]
引用
收藏
页码:2116 / 2121
页数:6
相关论文
共 50 条
  • [31] Shading correction assisted iterative cone-beam CT reconstruction
    Yang, Chunlin
    Wu, Pengwei
    Gong, Shutao
    Wang, Jing
    Lyu, Qihui
    Tang, Xiangyang
    Niu, Tianye
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (22): : 8495 - 8520
  • [32] Radiation Dose From Cone-Beam CT in Neuroradiology Applications
    Berris, Theocharis
    Gupta, Rajiv
    Rehani, Madan M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 755 - 761
  • [33] A prototype system of upright dedicated cone-beam breast CT
    Xu, Gongming
    Fang, Chengyijue
    Jiang, Xiao
    Zhu, Lei
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [34] Cone-Beam CT of the Extremities in Clinical Practice
    Doan, Matthew K.
    Long, Jeremiah R.
    Verhey, Erik
    Wyse, Aaron
    Patel, Karan
    Flug, Jonathan A.
    RADIOGRAPHICS, 2024, 44 (03)
  • [35] Exact consideration of data redundancies for spiral cone-beam CT
    Lauritsch, G
    Katsevich, A
    Hirsch, M
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2034 - 2045
  • [36] A diamond target for megavoltage cone-beam CT
    Sawkey, D.
    Lu, M.
    Morin, O.
    Aubin, M.
    Yom, S. S.
    Gottschalk, A. R.
    Bani-Hashemi, A.
    Faddegon, B. A.
    MEDICAL PHYSICS, 2010, 37 (03) : 1246 - 1253
  • [37] Correction of motion artifacts in cone-beam CT using a patient-specific respiratory motion model
    Zhang, Qinghui
    Hu, Yu-Chi
    Liu, Fenghong
    Goodman, Karyn
    Rosenzweig, Kenneth E.
    Mageras, Gig S.
    MEDICAL PHYSICS, 2010, 37 (06) : 2901 - 2909
  • [38] Cone-Beam CT in diagnosis of scaphoid fractures
    Edlund, Rolf
    Skorpil, Mikael
    Lapidus, Gunilla
    Backlund, Jenny
    SKELETAL RADIOLOGY, 2016, 45 (02) : 197 - 204
  • [39] Impact of cone-beam computed tomography artifacts on dose calculation accuracy for lung cancer
    Schroder, Lukas
    Bootsma, Gregory
    Stankovic, Uros
    Ploeger, Lennert
    Sonke, Jan-Jakob
    MEDICAL PHYSICS, 2024, 51 (07) : 4709 - 4720
  • [40] Design Optimization of Spatial-Spectral Filters for Cone-Beam CT Material Decomposition
    Tivnan, Matthew
    Wang, Wenying
    Gang, Grace
    Stayman, J. Webster
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (09) : 2399 - 2413