Crescent artifacts in cone-beam CT

被引:10
|
作者
Giles, William [1 ]
Bowsher, James [1 ]
Li, Hao
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Med Phys Grad Program, Durham, NC 27710 USA
关键词
crescent artifact; cone-beam CT; image reconstruction; COMPUTED-TOMOGRAPHY; SCATTER;
D O I
10.1118/1.3567508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In image-guided radiation therapy, cone-beam CT has been adopted for three-dimensional target localization in the treatment room. In many of these cone-beam CT images, dark and light crescent artifacts can be seen. This study investigates potential causes of this artifact and a technique for mitigating the crescents. Methods: Three deviations from an ideal geometry were simulated to assess their ability to cause crescent artifacts: Bowtie filter sag, x-ray tube sag, and x-ray tube rotation. The magnitudes of these deviations were estimated by matching shifts in simulated projections to those observed with clinical systems. To correct the artifacts, angle-dependent blank projections were acquired and incorporated into image reconstruction. The degree of artifact reduction was evaluated with varying numbers (1-380) of blank projections. Scanner-acquired phantom and patient studies were conducted to demonstrate the effectiveness of the proposed correction method. Results: All three investigated causes of the crescent artifact introduced similar mismodeling of the acquired projections and similar crescent artifacts. The deviations required for these artifacts were in the range of 0.5-5 mm or 0.1. RMS error is reduced from 8.91 x 10(-4) to 5.25 x 10(-7) for 1-380 blank projections over a 200 scan angle. In the patient and phantom studies, reconstructions that utilized 380 blank projections largely mitigated the crescent artifacts. Conclusions: Small deviations from an ideal geometry can result in crescent artifacts due to steep gradients in the bowtie filter. Angle-dependent blank projections can largely alleviate the artifacts. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3567508]
引用
收藏
页码:2116 / 2121
页数:6
相关论文
共 50 条
  • [21] Geometry calibration method for a cone-beam CT system
    Yang, Hongkai
    Kang, Kejun
    Xing, Yuxiang
    MEDICAL PHYSICS, 2017, 44 (05) : 1692 - 1706
  • [22] Reducing metal artifacts between implants in cone-beam CT by adjusting angular position of the subject
    Min, Chang-Ki
    Kim, Kyoung-A
    ORAL RADIOLOGY, 2021, 37 (03) : 385 - 394
  • [23] Cone Artifacts Correction in Iterative Cone Beam CT Reconstruction
    Yan, H.
    Wang, X.
    Bai, T.
    Lu, W.
    Folkerts, M.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 526 - 526
  • [24] CT Thermometry for Cone-beam CT Guided Ablation
    DeStefano, Zachary
    Abi-Jaoudeh, Nadine
    Li, Ming
    Wood, Bradford J.
    Summers, Ronald M.
    Yao, Jianhua
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [25] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [26] OR-EM Method for Image Reconstruction in Cone-beam CT
    Dong, Baoyu
    PROCEEDINGS OF THE FIRST INTERNATIONAL WORKSHOP ON EDUCATION TECHNOLOGY AND COMPUTER SCIENCE, VOL I, 2009, : 635 - 639
  • [27] Development of an MCNP-Based Cone-Beam CT Simulator
    Lim, Chang Hwy
    Cho, Mm Kook
    Han, Jong Chul
    Youn, Hanbean
    Yun, Seungman
    Cheong, Mm Ho
    Kim, Ho Kyung
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2009, 29 (04) : 351 - 359
  • [28] The influence of bowtie filtration on cone-beam CT image quality
    Mail, N.
    Moseley, D. J.
    Siewerdsen, J. H.
    Jaffray, D. A.
    MEDICAL PHYSICS, 2009, 36 (01) : 22 - 32
  • [29] A fast iteration approach to undersampled cone-beam CT reconstruction
    Zhu, Yechen
    Liu, Yangchuan
    Zhang, Qi
    Zhang, Cishen
    Gao, Xin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (01) : 111 - 129
  • [30] Orthogonal-rotating tetrahedral scanning for cone-beam CT
    Ye, Ivan B.
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506