Validity and Reliability of the Leomo Motion-Tracking Device Based on Inertial Measurement Unit with an Optoelectronic Camera System for Cycling Pedaling Evaluation

被引:9
作者
Plaza-Bravo, Jose Manuel [1 ]
Mateo-March, Manuel [2 ,3 ]
Sanchis-Sanchis, Roberto [4 ,5 ]
Perez-Soriano, Pedro [4 ,5 ]
Zabala, Mikel [1 ]
Encarnacion-Martinez, Alberto [4 ,5 ,6 ]
机构
[1] Univ Granada, Dept Phys Educ & Sports, E-18071 Granada, Spain
[2] Univ Miguel Hernandez de Elche, Sport Sci Dept, Elche 03202, Spain
[3] Univ Europea Madrid, Fac Sport Sci, Madrid 28670, Spain
[4] Univ Valencia, Res Grp Sports Biomech GIBD, E-46100 Valencia, Spain
[5] Univ Valencia, Dept Phys Educ & Sports, Valencia 46010, Spain
[6] Univ Catolica Murcia UCAM, Dept Sports Sci, Murcia 30107, Spain
关键词
motion analysis; cycling; kinematics; range of movement; IMU; SADDLE HEIGHT; KINEMATICS; VALIDATION; KNEE; WORK;
D O I
10.3390/ijerph19148375
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: The use of inertial measurement sensors (IMUs), in the search for a more ecological measure, is spreading among sports professionals with the aim of improving the sports performance of cyclists. The kinematic evaluation using the Leomo system (TYPE-R, Leomo, Boulder, CO, USA) has become popular. Purpose: The present study aimed to evaluate the reliability and validity of the Leomo system by measuring the angular kinematics of the lower extremities in the sagittal plane during pedaling at different intensities compared to a gold-standard motion capture camera system (OptiTrack, Natural Point, Inc., Corvallis, OR, USA). Methods: Twenty-four elite cyclists recruited from national and international cycling teams performed two 6-min cycles of cycling on a cycle ergometer at two different intensities (first ventilatory threshold (VT1) and second ventilatory threshold (VT2)) in random order, with a 5 min rest between intensity conditions. The reliability and validity of the Leomo system versus the motion capture system were evaluated. Results: Both systems showed high validity and were consistently excellent in foot angular range Q1 (FAR (Q1)) and foot angular range (FAR) (ICC-VT1 between 0.91 and 0.95 and ICC-VT2 between 0.88 and 0.97), while the variables leg angular range (LAR) and pelvic angle showed a modest validity (ICC-VT1 from 0.52 to 0.71 and ICC-VT2 between 0.61 and 0.67). Compared with Optitrack, Leomo overestimated all the variables, especially the LAR and pelvic angle values, in a range between 12 and 15 degrees. Conclusions: Leomo is a reliable and valid tool for analyzing the ranges of motion of the cyclist's lower limbs in the sagittal plane, especially for the variables FAR (Q1) and FAR. However, its systematic error for FAR and Pelvic Angle values must be considered in sports performance analysis.
引用
收藏
页数:13
相关论文
共 37 条
[1]   Effects of Bicycle Saddle Height on Knee Injury Risk and Cycling Performance [J].
Bini, Rodrigo ;
Hume, Patria A. ;
Croft, James L. .
SPORTS MEDICINE, 2011, 41 (06) :463-476
[2]  
Bini RR, 2009, KINESIOLOGY, V41, P25
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Stride length determination during overground running using a single foot-mounted inertial measurement unit [J].
Brahms, C. Markus ;
Zhao, Yang ;
Gerhard, David ;
Barden, John M. .
JOURNAL OF BIOMECHANICS, 2018, 71 :302-305
[6]  
Briff P., 2017, P 2017 8 ARGENTINE S, P1
[7]   Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review [J].
Camomilla, Valentina ;
Bergamini, Elena ;
Fantozzi, Silvia ;
Vannozzi, Giuseppe .
SENSORS, 2018, 18 (03)
[8]   Evaluating the validity and reliability of inertial measurement units for determining knee and trunk kinematics during athletic landing and cutting movements [J].
Chia, Lionel ;
Andersen, Jordan T. ;
McKay, Marnee J. ;
Sullivan, Justin ;
Megalaa, Tomas ;
Pappas, Evangelos .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2021, 60
[9]   Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems [J].
Cho, Young-Shin ;
Jang, Seong-Ho ;
Cho, Jae-Sung ;
Kim, Mi-Jung ;
Lee, Hyeok Dong ;
Lee, Sung Young ;
Moon, Sang-Bok .
ANNALS OF REHABILITATION MEDICINE-ARM, 2018, 42 (06) :872-883
[10]   Validity and Reliability of the Inertial Measurement Unit for Barbell Velocity Assessments: A Systematic Review [J].
Clemente, Filipe Manuel ;
Akyildiz, Zeki ;
Pino-Ortega, Jose ;
Rico-Gonzalez, Markel .
SENSORS, 2021, 21 (07)