Very fast wave-front measurements at the human eye with a custom CMOS-based Hartmann-Shack sensor

被引:55
作者
Nirmaier, T [1 ]
Pudasaini, G [1 ]
Bille, J [1 ]
机构
[1] Heidelberg Univ, Kirchhoff Inst Phys, D-69120 Heidelberg, Germany
关键词
D O I
10.1364/OE.11.002704
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe what we believe to be the first wave-front measurements of the human eye at a sampling rate of 300 Hz with a custom Hartmann-Shack wave-front sensor that uses complementary metal-oxide semiconductor (CMOS) technology. This sensor has been developed to replace standard charge-coupled device (CCD) cameras and the slow software image processing that is normally used to reconstruct the wave front from the focal-plane image of a lenslet array. We describe the sensor's principle of operation and introduce the performance with static wave fronts. The system has been used to measure human-eye wave-front aberrations with a bandwidth of 300 Hz, which is approximately an order of magnitude faster than with standard software-based solutions. Finally, we discuss the measured data and consider further improvements to the system. (C) 2003 Optical Society of America.
引用
收藏
页码:2704 / 2716
页数:13
相关论文
共 14 条
[1]  
Daniel M., 2006, Optical Shop Testing
[2]   Benefit of higher closed-loop bandwidths in ocular adaptive optics [J].
Diaz-Santana, L ;
Torti, C ;
Munro, I ;
Gasson, P ;
Dainty, C .
OPTICS EXPRESS, 2003, 11 (20) :2597-2605
[3]   An ASIC for Hartmann-Shack wavefront detection [J].
Droste, D ;
Bille, J .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2002, 37 (02) :173-182
[4]   Closed-loop adaptive optics in the human eye [J].
Fernández, EJ ;
Iglesias, I ;
Artal, P .
OPTICS LETTERS, 2001, 26 (10) :746-748
[5]   ACTIVE OPTICS - NEW TECHNOLOGY FOR CONTROL OF LIGHT [J].
HARDY, JW .
PROCEEDINGS OF THE IEEE, 1978, 66 (06) :651-697
[6]   Improvement in retinal image quality with dynamic correction of the eye's aberrations [J].
Hofer, H ;
Chen, L ;
Yoon, GY ;
Singer, B ;
Yamauchi, Y ;
Williams, DR .
OPTICS EXPRESS, 2001, 8 (11) :631-643
[7]   Dynamics of the eye's wave aberration [J].
Hofer, H ;
Artal, P ;
Singer, B ;
Aragón, JL ;
Williams, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (03) :497-506
[8]  
LAZARRO J, 1998, ADV NEURAL INFORMATI, P703
[9]  
LIANG J, 1994, J OPT SOC AM, V11
[10]   Supernormal vision and high-resolution retinal imaging through adaptive optics [J].
Liang, JZ ;
Williams, DR ;
Miller, DT .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2884-2892