Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device

被引:32
作者
Ahlhelm, Frank [1 ]
Roth, Christian
Kaufmann, Ralf
Schulte-Altedorneburg, Gernot
Romeike, Bernd F. M.
Reith, Wolfgang
机构
[1] Univ Saarland, Sch Med, Clin Diagnost & Intervent Neuroradiol, D-66421 Homburg, Germany
[2] JOTEC Gmbh, Dept Res & Dev Stenting Technol, D-72379 Hechingen, Germany
[3] Univ Saarland, Sch Med, Inst Neuropathol, D-66421 Homburg, Germany
[4] Univ Jena, Dept Neuropathol, D-07747 Jena, Germany
关键词
animal experiment; interventional neuroradiology; stenting; wide-necked aneurysm;
D O I
10.1007/s00234-007-0281-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction Endovascular treatment of intracerebral wide-necked aneurysms carries the risk of incomplete embolisation and recanalisation of the aneurysm as well as coil protrusion into the parent artery and embolic complications. We present preliminary results with the placement of a novel tightly braided stent across the aneurysm neck which might lead to thrombosis of these aneurysms. Methods A bifurcation artery aneurysm was created in a male New Zealand White Rabbit. After 4 weeks, a novel highly flexible stent with a central tightly braided mesh was placed across the aneurysm neck. Diagnostic angiography was performed during the procedure and immediately after stent deployment as well as 2 and 4 weeks following stent placement. Histological analyses, including microscopic investigations for evaluating intra-aneurysmal thrombosis and proliferation of the intima, were performed after 1 month. Results Intra-aneurysmal flow reduction due to stent placement was achieved as early as 45 min after deployment. Unchanged complete occlusion of the aneurysm could be observed by angiography 2 and 4 weeks post-stent deployment. Histological analysis confirmed angiographical findings of complete aneurysm occlusion and excluded significant neointimal coverage. Conclusion This newly designed flexible stent may offer the potential to expand endovascular treatment of wide-necked intracranial aneurysms.
引用
收藏
页码:1023 / 1028
页数:6
相关论文
共 23 条
  • [1] Thrombosis of a fusiform intracranial aneurysm induced by overlapping Neuroform stents: Case report
    Ansari, Sameer A.
    Lassig, Jeffrey P.
    Nicol, Ewen
    Thompson, B. Gregory
    Gemmete, Joseph J.
    Gandhi, Dheeraj
    [J]. NEUROSURGERY, 2007, 60 (05) : 950 - 951
  • [2] BARATH K, 2005, NEUROL RES, V27, P120
  • [3] SELECTIVE ENDOVASCULAR TREATMENT OF 71 INTRACRANIAL ANEURYSMS WITH PLATINUM COILS
    CASASCO, AE
    AYMARD, A
    GOBIN, YP
    HOUDART, E
    ROGOPOULOS, A
    GEORGE, B
    HODES, JE
    COPHIGNON, J
    MERLAND, JJ
    [J]. JOURNAL OF NEUROSURGERY, 1993, 79 (01) : 3 - 10
  • [4] Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils
    Cognard, C
    Weill, A
    Spelle, L
    Piotin, M
    Castaings, L
    Rey, A
    Moret, J
    [J]. RADIOLOGY, 1999, 212 (02) : 348 - 356
  • [5] Double-stent method: therapeutic alternative for small wide-necked aneurysms
    Doerfler, A
    Wanke, I
    Egelhof, T
    Stolke, D
    Forsting, M
    [J]. JOURNAL OF NEUROSURGERY, 2004, 100 (01) : 150 - 154
  • [6] Balloon-in-stent technique for the constructive endovascular treatment of "ultra-wide necked" circumferential aneurysms
    Fiorella, D
    Albuquerque, FC
    Masaryk, TJ
    Rasmussen, PA
    McDougall, CG
    [J]. NEUROSURGERY, 2005, 57 (06) : 1218 - 1226
  • [7] Fiorella D, 2006, NEUROSURGERY, V59, P291, DOI 10.1227/01.NEU.0000223650.11954.6C
  • [8] Anticoagulation regimes and their influence on the occlusion rate of aneurysms: An experimental study in rabbits
    Grunwald, IQ
    Romeike, BF
    Roth, C
    Struffert, T
    Eymann, R
    Reith, W
    [J]. NEUROSURGERY, 2005, 57 (05) : 1048 - 1054
  • [9] Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system
    Hayakawa, M
    Murayama, Y
    Duckwiler, GR
    Gobin, YP
    Guglielmi, G
    Viñuela, F
    [J]. JOURNAL OF NEUROSURGERY, 2000, 93 (04) : 561 - 568
  • [10] Characterization of flow reduction properties in an aneurysm due to a stent -: art. no. 021918
    Hirabayashi, M
    Ohta, M
    Rüfenacht, DA
    Chopard, B
    [J]. PHYSICAL REVIEW E, 2003, 68 (02):