Experimental and CFD evaluation of ozone efficacy against coronavirus and enteric virus contamination on public transport surfaces

被引:5
作者
Falco, Irene [1 ]
Randazzo, Walter [1 ]
Sanchez, Gloria [1 ]
Vilarroig, Jose [2 ]
Climent, Javier [2 ]
Chiva, Sergio [3 ]
Chica, A. [4 ]
Navarro-Laboulais, J. [5 ]
机构
[1] CSIC, IATA, Inst Agrochem & Food Technol, Dept Preservat & Food Safety Technol, Av Agustin Escardino 7, Valencia 46980, Spain
[2] Hydrodynam & Environm Serv, Av Mar,53, Castellon de La Plana 12003, Spain
[3] Univ Jaume 1, Dept Mech Engn & Construct, Av Vicent Sos Baynat,S-N, Castellon de La Plana 12071, Spain
[4] Univ Politecn Valencia, Consejo Super Invest Cient, Inst Tecnol Quim, Avd Naranjos S-N, Valencia 46022, Spain
[5] Univ Politecn Valencia, Dept Chem & Nucl Engn, Camino Vera S-N, Valencia 46022, Spain
来源
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING | 2021年 / 9卷 / 05期
关键词
Ozonation; Disinfection; SARS-CoV-2; Coronavirus; Enteric virus; CFD public transport; GAS-PHASE; AIRBORNE TRANSMISSION; INDOOR ENVIRONMENTS; DECOMPOSITION; INACTIVATION; MECHANISM; PRODUCTS; KINETICS; REMOVAL; IMPACT;
D O I
10.1016/j.jece.2021.106217
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The limited information about the routes of the transmission of SARS-CoV-2 within the ongoing pandemic scenario mobilized the administration, industry and academy to develop sanitation and disinfection systems for public and private spaces. Ozone has been proposed as an effective disinfection method against enveloped and non-enveloped viruses, including viruses with similar morphology to SARS-CoV-2. Due to this efficacy, numerous gaseous and aqueous phase ozone applications have emerged potentially to inhibit virus persistence in aerosols, surfaces, and water. In this work, a numerical model, a RANS CFD model for ozone dispersion inside tram and underground coach has been developed including the chemical self-decomposition and surface reactions of the ozone. The CFD model has been developed for a real tram coach of 28.6 x 2.4 x 2.2 m (L x W x H) using 1.76 million nodes and the Menter's shear stress transport turbulence model. The model predicts the O-3 concentration needed to meet disinfection criteria and the fluid dynamics inside the public transport coach. The effectiveness of the system has been validated with laboratory and field tests in real full-scale coach using porcine epidemic diarrhea virus (PEDV) and murine norovirus (MNV-1) as SARS-CoV-2 and human norovirus surrogates, respectively. Lab-scale experiments on plastic surfaces demonstrated O3 disinfection (100 ppm, 95% RH, 25 min) inactivate > 99.8% MNV-1 and PEDV. Additionally, field tests in real full-scale coach demostrate the efficacy of the system as > 98.6% of infectious MNV-1 and > 96.3% PEDV were inactivated.
引用
收藏
页数:12
相关论文
共 52 条
[41]   Modeling-gas phase reactions in indoor environments using computational fluid dynamics [J].
Sorensen, DN ;
Weschler, CJ .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (01) :9-18
[42]   The airborne lifetime of small speech droplets and their potential importance in SARS-CoV-2 transmission [J].
Stadnytskyi, Valentyn ;
Bax, Christina E. ;
Bax, Adriaan ;
Anfinrud, Philip .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2020, 117 (22) :11875-11877
[43]   CRITICAL SURVEY OF DATA ON THE SPECTROSCOPY AND KINETICS OF OZONE IN THE MESOSPHERE AND THERMOSPHERE [J].
STEINFELD, JI ;
ADLERGOLDEN, SM ;
GALLAGHER, JW .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1987, 16 (04) :911-951
[44]   Factors affecting ozone removal rates in a simulated aircraft cabin environment [J].
Tamas, Gyongyi ;
Weschler, Charles J. ;
Bako-Biro, Zsolt ;
Wyon, David P. ;
Strom-Tejsen, Peter .
ATMOSPHERIC ENVIRONMENT, 2006, 40 (32) :6122-6133
[45]   Ozone: A Potential Oxidant for COVID-19 Virus (SARS-CoV-2) [J].
Tizaoui, Chedly .
OZONE-SCIENCE & ENGINEERING, 2020, 42 (05) :378-385
[46]  
Tseng C, 2008, J ENVIRON HEALTH, V70, P56
[47]   Effect of ozone treatment on surface properties of activated carbon [J].
Valdés, H ;
Sánchez-Polo, M ;
Rivera-Utrilla, J ;
Zaror, CA .
LANGMUIR, 2002, 18 (06) :2111-2116
[48]  
van Doremalen N, 2020, NEW ENGL J MED, V382, P1564, DOI [10.1101/2020.03.09.20033217, 10.1056/NEJMc2004973]
[49]   Ozone's impact on public health: Contributions from indoor exposures to ozone and products of ozone-initiated chemistry [J].
Weschler, Charles J. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2006, 114 (10) :1489-1496
[50]   Ozone in indoor environments: Concentration and chemistry [J].
Weschler, CJ .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (04) :269-288