Comparison of enhancement and image quality: different iodine concentrations for liver on 128-slice multidetector computed tomography in the same chronic liver disease patients

被引:9
|
作者
Jo, Byoung Goo [1 ]
Song, Yun Gyu [1 ]
Shim, Sang Goon [2 ]
Kim, Young Wook [3 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Changwon Hosp, Dept Radiol, 158 Paryong Ro, Chang Won 51353, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Changwon Hosp, Dept Internal Med, Chang Won, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Changwon Hosp, Dept Occupat & Environm Med, Chang Won, South Korea
关键词
Multidetector computed tomography; Liver; Contrast media; Iodine; CONCENTRATION CONTRAST-MEDIA; HEPATOCELLULAR-CARCINOMA; HEPATIC ENHANCEMENT; HELICAL CT; CORONARY-ANGIOGRAPHY; INJECTION PROTOCOL; PORCINE MODEL; SPIRAL CT; ROW CT; MDCT;
D O I
10.3904/kjim.2014.210
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aims: The objective of this study was to compare the degree of hepatic enhancement and image quality using contrast media of different iodine concentrations with the same iodine dose. Methods: From July 2011 to June 2013, 50 patients with chronic liver disease who underwent baseline and follow-up 128-slice multidetector computed tomography (MDCT) using contrast media with 350 mg I/mL (group A) and 400 mg I/mL (group B) iodine concentrations were included in this prospective study. The patients were randomly allocated to one of two protocols: 350 mg I/mL initially and then 400 mg I/mL; and 400 mg I/mL initially and then 350 mg I/mL. The bolus tracking technique was used to initiate the arterial phase scan. The computed tomography values of hepatic parenchyma, abdominal aorta and portal vein were measured. The degrees of hepatic and vascular enhancement were rated on a 4-point scale for qualitative assessment. The paired Student t test was used to compare outcome variables. Results: The mean hepatic enhancement was significantly higher in group B than in group A during the portal (p = 0.025) and equilibrium phases (p = 0.021). In all phases, group B had significantly higher mean liver-to-aorta contrast (p < 0.05) and mean visual scores for hepatic and vascular enhancement (p < 0.001). Conclusions: This study showed that a higher iodine concentration (400 mg I/mL) in contrast media was more effective at improving hepatic enhancement in portal and equilibrium phase images and overall image quality using 128-slice MDCT in chronic liver disease patients
引用
收藏
页码:461 / 469
页数:9
相关论文
共 26 条
  • [1] Multidetector helical computed tomography of the liver: Comparison of hepatic enhancement using two different contrast media strategies
    Smith, JC
    Nelson, RC
    Gimenez, EI
    Heneghan, JP
    Thomas, J
    Delong, DM
    Kurylo, LM
    ACADEMIC RADIOLOGY, 2004, 11 (03) : 267 - 271
  • [2] Partial anomalous pulmonary venous return and atrial septal defect in adult patients detected with 128-slice multidetector computed tomography
    Kivisto, Sari
    Hanninen, Helena
    Holmstrom, Miia
    JOURNAL OF CARDIOTHORACIC SURGERY, 2011, 6
  • [3] Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries
    Joern J. W. Sandstede
    Christine Kaupert
    Anne Roth
    Manfred Jenett
    Cornelia Harz
    Dietbert Hahn
    European Radiology, 2005, 15 : 1211 - 1214
  • [4] Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries
    Sandstede, JJW
    Kaupert, C
    Roth, A
    Jenett, M
    Harz, C
    Hahn, D
    EUROPEAN RADIOLOGY, 2005, 15 (06) : 1211 - 1214
  • [5] Dose and image quality of high-pitch dual source computed tomography for the evaluation of cervical lymph node status - Comparison to regular 128-slice single source computed tomography
    Bodelle, Boris
    Bauer, Ralf W.
    Holthaus, Lara
    Schulz, Boris
    Al-Butmeh, Firas
    Wichmann, Julian L.
    Beeres, Martin
    Vogl, Thomas J.
    Kerl, J. Matthias
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (06) : E281 - E285
  • [6] Computed tomography image quality in patients with primary hepatocellular carcinoma: intraindividual comparison of contrast agent concentrations
    Peng, Fei
    Luo, Chaotian
    Ning, Xiaojing
    Xiao, Fangyan
    Guan, Kaiming
    Tang, Cheng
    Huang, Fuling
    Liang, Junli
    Peng, Peng
    FRONTIERS IN MEDICINE, 2024, 11
  • [7] Comparison of iodixanol 320 and iohexol 350 in image quality during 64-slice multidetector computed tomography: Prospective randomized study
    Choi, Tae-Young
    Woo, Vincent
    Gupta, Mohit
    Sourayanezhad, Souraya
    Li, Dong
    Mao, Song S.
    Budoff, Matthew
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 158 (01) : 134 - 138
  • [8] Imaging of liver disease: Comparison between quadruple-phase multidetector computed tomography and magnetic resonance imaging
    Balci, N. Cem
    Befeler, Alex S.
    Leiva, Paula
    Pilgram, Thomas K.
    Havlioglu, Necat
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 (10) : 1520 - 1527
  • [9] Comparison between Doppler ultrasonography and multiphase multidetector-row computed tomography in the detection of liver involvement in Rendu-Osler disease: An analysis of 62 patients
    Cavel, A.
    Bleuzen, A.
    Bertrand, P.
    Patat, F.
    Cottier, J. -P.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 451 - 459
  • [10] Assessment of liver fibrosis severity using computed tomography–based liver and spleen volumetric indices in patients with chronic liver disease
    Jung Hee Son
    Seung Soo Lee
    Yedaun Lee
    Bo-Kyeong Kang
    Yu Sub Sung
    SoRa Jo
    Eunsil Yu
    European Radiology, 2020, 30 : 3486 - 3496