Real-time association rate constant measurement using combination tapered fiber-optic biosensor (CTFOB) dip-probes

被引:0
|
作者
Simmonds, Boris [1 ]
Wang, Chun-Wei [1 ]
Kapoor, Rakesh [1 ]
机构
[1] UAB, Dept Phys, Birmingham, AL 35294 USA
来源
OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X | 2010年 / 7559卷
关键词
association constant; BSA; anti-BSA; fiber-optic; biosensor; real-time;
D O I
10.1117/12.843266
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This document reports a novel method of measuring association rate constant (k(a)) for antibody-antigen interaction using evanescent wave-based combination tapered fiber-optic biosensor (CTFOB) dip-probes. The method was demonstrated by measuring association rate constant for bovine serum albumin (BSA) and anti-BSA antibody interaction. "Direct method" was used for detection; goat anti-BSA "capture" antibodies were immobilized on the probe surfaces while the antigen (BSA) was directly labeled with Alexa 488 dye. The probes were subsequently submerged in 3nM Labeled BSA in egg albumin (1 mg/ml). The fluorescence signal recorded was proportional to BSA anti-BSA conjugates and continuous signal was acquired suing a fiber optic spectrometer (Ocean Optics, Inc.). A 476 nm diode laser was use as an excitation source. Association constant was estimated from a plot of signal as a function of time. Measured association rate constant k(a) for the binding of BSA with anti-BSA at room temperature is (8.33 +/- 0.01) x 10(4)M(-1)s(-1).
引用
收藏
页数:5
相关论文
共 40 条
  • [1] Dissociation constant measurement using combination tapered fiber-optic biosensor (CTFOB) dip-probes
    Wang, Chun-Wei
    Kapoor, Rakesh
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X, 2010, 7559
  • [2] Fiber-optic probes for real-time pH monitoring
    Elsherif, Mohamed
    Alam, Fahad
    Salih, Ahmed E.
    Wang, Xinyu
    Corridon, Peter R.
    Ramadi, Khalil B.
    Butt, Haider
    SENSORS & DIAGNOSTICS, 2024, 3 (05): : 827 - 838
  • [3] Highly specific detection of IL-8 protein using combination tapered fiber-optic biosensor dip-probe
    Wang, Chun-Wei
    Kapoor, Rakesh
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X, 2010, 7559
  • [4] Development of combination tapered fiber-optic biosensor dip probe for quantitative estimation of interleukin-6 in serum samples
    Wang, Chun Wei
    Manne, Upender
    Reddy, Vishnu B.
    Oelschlager, Denise K.
    Katkoori, Venkat R.
    Grizzle, William E.
    Kapoor, Rakesh
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (06)
  • [5] Serum albumin measurement using a tapered fluorescent fiber-optic evanescent wave-based biosensor
    Preejith, Pv
    Lim, Cs
    Chia, Tf
    2006 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND PHARMACEUTICAL ENGINEERING, VOLS 1 AND 2, 2006, : 388 - +
  • [6] Highly specific detection of interleukin-6 (IL-6) protein using combination tapered fiber-optic biosensor dip-probe
    Kapoor, Rakesh
    Wang, Chun-Wei
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2696 - 2701
  • [7] Birefringence Variation Independent Fiber-Optic Current Sensor Using Real-Time SOP Measurement
    Liu, Yinping
    Ma, Lin
    He, Zuyuan
    IEEE PHOTONICS JOURNAL, 2017, 9 (05):
  • [8] Fiber-Optic Based Smart Textiles for Real-Time Monitoring of Breathing Rate
    Issatayeva, Aizhan
    Beisenova, Aidana
    Tosi, Daniele
    Molardi, Carlo
    SENSORS, 2020, 20 (12) : 1 - 16
  • [9] Development of combination tapered fiber-optic biosensor dip probe for quantitative estimation of interleukin-6 in serum samples (vol 15, 067005, 2010)
    Wang, Chun Wei
    Manne, Upender
    Reddy, Vishnu B.
    Oelschlager, Denise K.
    Katkoori, Venkat R.
    Grizzle, William E.
    Kapoor, Rakesh
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)
  • [10] Signal processing of real-time monitoring system using embedded fiber-optic sensors
    Wu, P
    Kang, L
    Lin, YY
    FIBER OPTIC SENSORS V, 1996, 2895 : 542 - 547