Early and late graft occlusion remains a significant complication of coronary artery bypass grafting. Transit time flowmetry is the most commonly used imaging technique to assess graft patency intraoperatively. Although the value of transit time flowmetry for intraoperative quality control of coronary anastomosis is well established, its standard variables for predicting eventual graft failure remain controversial. This review readdresses the issue of intraoperative transit time flowmetry, with a particular emphasis on defining cutoff values for standard variables and correlating them with the ability to predict midterm and long-term graft patency for arterial and venous conduits. Further research is warranted to support clinically useful recommendations on the intraoperative application and interpretation of transit time flowmetry. (C) 2016 by The Society of Thoracic Surgeons
引用
收藏
页码:1996 / 2006
页数:11
相关论文
共 34 条
[1]
Alexander JH, 2005, JAMA-J AM MED ASSOC, V294, P2446