Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat

被引:40
作者
Buono, Michael J. [1 ]
Jechort, Amy [1 ]
Marques, Raquel [1 ]
Smith, Carrie [1 ]
Welch, Jessica [1 ]
机构
[1] San Diego State Univ, San Diego, CA 92182 USA
关键词
skin temperature; infrared thermometry; contact thermistors; exercise;
D O I
10.1088/0967-3334/28/8/008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study was to determine the validity of non-contact infrared thermometry to measure mean skin temperature in resting and exercising subjects in cold, thermo-neutral and hot environments. The subjects for the study were six healthy volunteers. Skin temperature was measured at three sites: the forearm, chest and calf on each subject using both contact thermistors and a non-contact infrared thermometer. Data were collected at rest and during exercise in three different air temperatures (15, 25 and 35 degrees C). The correlation of resting mean skin temperature using infrared thermometry and contact thermistors was r = 0.95, while the correlation obtained during exercise was r = 0.98. The results of the current study strongly suggest that infrared thermometry is a valid measure of skin temperature during rest and exercise in both hot and cold environments. It is hoped that the results of this study will encourage the use of non-contact infrared thermometry by both clinicians and exercise, environmental, and sleep researchers in the future.
引用
收藏
页码:855 / 859
页数:5
相关论文
共 9 条
[1]  
[Anonymous], 1977, COMPUTATIONAL HDB ST
[2]   Comparison of mean skin temperature using 'covered' versus 'uncovered' contact thermistors [J].
Buono, MJ ;
Ulrich, RL .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) :297-300
[3]   A new technic for the measurement of average skin temperature over surfaces of the body and the changes of skin temperature during exercise [J].
Burton, AC .
JOURNAL OF NUTRITION, 1934, 7 (05) :481-496
[4]   ASSESSMENT OF AN INFRARED NONCONTACT SENSOR FOR ROUTINE SKIN TEMPERATURE MONITORING - A PRELIMINARY-STUDY [J].
HERSHLER, C ;
CONINE, TA ;
NUNN, A ;
HANNAY, M .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1992, 16 (03) :117-122
[5]   Comparison of infrared thermometer with thermocouple for monitoring skin temperature [J].
Matsukawa, T ;
Ozaki, M ;
Nishiyama, T ;
Imamura, M ;
Kumazawa, T .
CRITICAL CARE MEDICINE, 2000, 28 (02) :532-536
[6]   CIRCULATORY REGULATION DURING EXERCISE IN DIFFERENT AMBIENT-TEMPERATURES [J].
NADEL, ER ;
CAFARELLI, E ;
ROBERTS, MF ;
WENGER, CB .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (03) :430-437
[7]   SPECTRAL EMISSIVITY OF SKIN AND PERICARDIUM [J].
STEKETEE, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (05) :686-694
[8]   Comparison of digital infrared thermal imaging (DITI) with contact thermometry: pilot data from a sleep research laboratory [J].
van den Heuvel, CJ ;
Ferguson, SA ;
Dawson, D ;
Gilbert, SS .
PHYSIOLOGICAL MEASUREMENT, 2003, 24 (03) :717-725
[9]   HUMAN THERMOREGULATORY RESPONSES TO COLD AIR ARE ALTERED BY REPEATED COLD WATER IMMERSION [J].
YOUNG, AJ ;
MUZA, SR ;
SAWKA, MN ;
GONZALEZ, RR ;
PANDOLF, KB .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (05) :1542-1548