Sustained accuracy improvement in intraocular lens power calculation with the application of quality control circle

被引:9
作者
Lin, Lei [1 ]
Chang, Pingjun [1 ]
Xie, Jialu [1 ]
Li, Zhangliang [1 ]
Zhang, Hongfang [1 ]
Lu, Fan [1 ]
Zhao, Yun-e [1 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
关键词
REFRACTIVE OUTCOMES; 8108; EYES; BIOMETRY; CONSTANT;
D O I
10.1038/s41598-017-14171-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Accurate intraocular lens (IOL) power calculation is always a challenge in ophthalmology, and unoptimized process may lead to inaccurate refractive outcomes. Quality control circle (QCC) has shown its success in many fields as a process management tool. However, its efficacy in ophthalmology remains unclear. Here we utilized the QCC method to optimize the process and evaluate its efficacy in improving the accuracy of IOL power calculation. After the QCC application, the percentage of eyes with achieved refractive outcomes within 0.5 diopter significantly increased from 63.2% to 80.8% calculated by Haigis formula and 59.2% to 75.8% by SRK/T formula in patients with normal axial length (AL) (22 mm = AL < 26 mm). Although there were no statistically significant differences in patients with long AL by the two formulas (p = 0.886 and 0.726), we achieved an accuracy of 75% with the application of the PhacoOptics software, which was significantly higher than that using the other two formulas (p < 0.001). Our findings indicated that QCC optimized and standardized the process of IOL power calculation, thus improved the accuracy of IOL power calculation in patients who underwent cataract surgery.
引用
收藏
页数:7
相关论文
共 28 条
[1]  
Abulafia A., J CATARACT REFRACTIV, V41, P548
[2]   Intraocular lens formula constant optimization and partial coherence interferometry biometry: Refractive outcomes in 8108 eyes after cataract surgery [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :50-62
[3]   Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :63-71
[4]  
Arnedos M., CLIN ONCOLOGY, V12, P693
[5]   Role of quality control circle in sustained improvement of hand hygiene compliance: an observational study in a stomatology hospital in Shandong, China [J].
Chen, Peng ;
Yuan, Ting ;
Sun, Qinfeng ;
Jiang, Lili ;
Jiang, Hongmin ;
Zhu, Zhenkun ;
Tao, Zexin ;
Wang, Haiyan ;
Xu, Aiqiang .
ANTIMICROBIAL RESISTANCE AND INFECTION CONTROL, 2016, 5
[6]   A New Initiative on Precision Medicine [J].
Collins, Francis S. ;
Varmus, Harold .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (09) :793-795
[7]   Comparison of 9 intraocular lens power calculation formulas [J].
Cooke, David L. ;
Cooke, Timothy L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1157-1164
[8]   Translating cancer research into targeted therapeutics [J].
de Bono, J. S. ;
Ashworth, Alan .
NATURE, 2010, 467 (7315) :543-549
[9]   Can quality circles improve hospital-acquired infection control? [J].
Forster, DH ;
Krause, G ;
Gastmeier, P ;
Ebner, W ;
Rath, A ;
Wischnewski, N ;
Lacour, M ;
Rüden, H ;
Daschner, FD .
JOURNAL OF HOSPITAL INFECTION, 2000, 45 (04) :302-310
[10]   Benchmark standards for refractive outcomes after NHS cataract surgery [J].
Gale, R. P. ;
Saldana, M. ;
Johnston, R. L. ;
Zuberbuhler, B. ;
McKibbin, M. .
EYE, 2009, 23 (01) :149-152