Due to Global Warming concerns, switchgear with lower Global Warming Potential (GWP) may become desirable. This work investigates using very low (<10%) levels of Sulfur Hexafluoride (SF(6)) along with common gases for insulating Switchgear. Design of Experiments (DOE) is used to isolate significant factors and to generate a model, an empirical equation for predictive use. For calculating GWP of gas mixtures, a weighted average calculation is made. Results show that mixtures of 0-5% SF(6) and Carbon Dioxide (CO(2)) may be sufficient for 15 kV class equipment, and 3-8.5 % SF(6) with CO(2) may be sufficient for 25 kV. In this work, CO(2) was more effective than Nitrogen. Using the weighted average calculation for GWP, these blends compare favorably with the automotive air conditioner refrigerant (R-134a, GWP = 1,300) in common use today. R-134a is approved by international agreement for automotive use to 2030(l). The resulting DOE model proved to have excellent predictive power.
引用
收藏
页码:751 / 754
页数:4
相关论文
共 50 条
  • [1] The Insulation Performance of Novel Refrigerant Gas as an Alternative to SF6 for Medium Voltage Switchgear
    Ahmed, Rizwan
    Abd-Rahman, Rahisham
    Ullah, Zahid
    Ullah, Rahmat
    Sami, Irfan
    Yousof, Mohd Fairouz Mohd
    IEEE ACCESS, 2024, 12 : 47068 - 47079
  • [2] TRENDS IN MEDIUM VOLTAGE SF6 SWITCHGEAR.
    Rosen, P.R.
    Elektron, 1986, 3 (10): : 11 - 15
  • [3] Superhigh-voltage distributive switchgear with SF6 insulation
    Babkin, I.V.
    Berlin, B.E.
    Vishnevskii, Yu.I.
    Lopaev, V.N.
    Tret'yakov, S.V.
    Russian Electrical Engineering, 2003, 74 (11) : 26 - 33
  • [4] HIGH-VOLTAGE METALCLAD SWITCHGEAR INSTALLATIONS WITH SF6 INSULATION
    SZENTEVA.HP
    BROWN BOVERI REVIEW, 1969, 56 (07): : 345 - &
  • [5] MEDIUM-VOLTAGE SWITCHGEAR EAK WITH VACUUM CIRCUIT-BREAKERS AND SF6 GAS INSULATION
    GRAFLING, J
    SCHEMMANN, B
    BROWN BOVERI REVIEW, 1986, 73 (11): : 629 - 637
  • [6] SF6 GAS TECHNOLOGY AS USED IN MEDIUM VOLTAGE SWITCHGEAR.
    Martin, George O.
    Certificated engineer, 1984, 57 (07): : 112 - 115
  • [7] Investigation of Arc Splitters in an SF6 Insulated Medium Voltage Switchgear
    Novak, B.
    Sonar, R.
    Sivaraj, R.
    2017 63RD IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2017, : 242 - 248
  • [8] MEDIUM-VOLTAGE SWITCHGEAR EAK WITH VACUUM CIRCUIT-BREAKERS, AND SF6 GAS INSULATION.
    Graefling, J.
    Schemmann, B.
    1600, (73):
  • [9] HIGH-VOLTAGE SWITCHGEAR IN NEAR FUTURE - METAL CLAD WITH SF6 INSULATION OR CONVENTIONAL SWITCHGEAR
    LEVA, E
    ELETTROTECNICA, 1973, 60 (08): : 761 - 769
  • [10] H SYSTEM - NEW GENERATION OF SF6 MEDIUM-VOLTAGE SWITCHGEAR
    SCHAUMANN, R
    POOLE, D
    BROWN BOVERI REVIEW, 1977, 64 (11): : 644 - 649