Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study

被引:14
|
作者
Chang, Rai-Jei [1 ]
Chen, Hui-Ling [2 ,4 ]
Huang, Liang-Gie [1 ]
Wong, Yong-Kie [3 ,4 ]
机构
[1] Taichung Vet Gen Hosp, Dept Stomatol, Div Endodont & Periodontol, Taichung, Taiwan
[2] Taichung Vet Gen Hosp, Dept Stomatol, Div Dent Implant, Taichung, Taiwan
[3] Chang Bing Show Chan Mem Hosp, Dept Dent, Div Oral & Maxillofacial Surg, Changhua, Taiwan
[4] Natl Yang Ming Univ, Sch Dent, Taipei, Taiwan
关键词
Accuracy; Computer-aided surgery; Dental implant; IN-VITRO; TECHNOLOGY APPLICATIONS; ORAL IMPLANTS; DENTISTRY; SURGERY; SUCCESS; IMAGES;
D O I
10.1016/j.jcma.2018.04.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A precise positioning for dental implant placement is important for further prosthesis fabrication and maintenance. Computer-aided surgery has been developed to transfer digitally planned implant positioning to the patient over the past decades. This study aimed to evaluate the accuracy of a computer-aided laboratory-fabricated surgical template. A further objective was to compare the accuracy between in vivo and in vitro groups. Methods: A total of 20 implants were placed in the posterior tooth region through the aid of surgical templates on 17 partially edentulous patients in the in vivo group. The surgical template was fabricated in laboratory after virtual implant planning was completed using computer software. In the in vitro group, the same procedures were performed on the models without placing fixture with the same templates used in surgery. Deviations of the implant access at the implant platform level and apical region, as well as the angle deviations between the virtual planning data and the surgical results, were measured using a follow-up Cone Beam Computerized Tomography (CBCT) investigation, and image fusion with planning data. Result: The median deviation at platform level, apex and angulation was 0.95 mm (0.3-1.3 mm), 1.35 mm (0.1-3.6 mm) and 3.92 degrees (0.44-11.66 degrees) respectively in the in vivo group; and 0.4 mm (0-1.0 mm), 0.65 mm (0.1-1.9 mm), 2.16 degrees (0.17-6.91) respectively in the in vitro group. The in vitro group displayed significantly less deviation (p < 0.05). Conclusion: The data from this study shows that computer-aided laboratory-fabricated template may be a reliable tool for implant placement. However, the clinical conditions seem to affect the accuracy of the template. Copyright (C) 2018, the Chinese Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:970 / 976
页数:7
相关论文
共 50 条
  • [31] Dental implant placement using computer-aided three-dimensional navigated procedures
    Nitsche, Tobias
    Menzebach, Marc
    Wiltfang, Joerg
    IMPLANTOLOGIE, 2011, 19 (03): : 243 - 250
  • [32] Accuracy of Two Stereolithographic Guide Systems for Computer-Aided Implant Placement: A Computed Tomography-Based Clinical Comparative Study
    Arisan, Volkan
    Karabuda, Z. Cuneyt
    Ozdemir, Tayfun
    JOURNAL OF PERIODONTOLOGY, 2010, 81 (01) : 43 - 51
  • [33] Influence of the macrodesign of an implant and the sleeve system on the accuracy of template-guided implant placement: A prospective clinical study
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Wetzel, Martin
    Luthardt, Ralph G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (02) : 212 - 219
  • [34] Evaluation of Three Different Validation Procedures regarding the Accuracy of Template-Guided Implant Placement: An In Vitro Study
    Vasak, Christoph
    Strbac, Georg D.
    Huber, Christian D.
    Lettner, Stefan
    Gahleitner, Andre
    Zechner, Werner
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (01) : 142 - 149
  • [35] Three-Dimensional Accuracy of Surgical Guides for Static Computer-Aided Implant Surgery: A Systematic Review
    Lo Russo, Lucio
    Pierluigi, Mariani
    Zhurakivska, Khrystyna
    Digregorio, Chiara
    Lo Muzio, Eleonora
    Laino, Luigi
    PROSTHESIS, 2023, 5 (03): : 809 - 825
  • [36] Accuracy of template-based guided dental implant placement-An in vitro comparison of different manufacturing methods
    Sium-Abel, Aura
    Keilig, Ludger
    Doersam, Istabrak
    Bourauel, Christoph
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 864 - 875
  • [37] A retrospective study of the accuracy of template-guided versus freehand implant placement: A nonradiologic method
    Alevizakos, Vasilios
    Mitov, Gergo
    Stoetzer, Marcus
    von See, Constantin
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 128 (03): : 220 - 226
  • [38] An Accuracy Study of Computer-Planned Implant Placement in the Augmented Maxilla Using Mucosa-Supported Surgical Templates
    Verhamme, Luc M.
    Meijer, Gert J.
    Berge, Stefaan J.
    Soehardi, Rik A.
    Xi, Tong
    de Haan, Anton F. J.
    Schutyser, Filip
    Maal, Thomas J. J.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (06) : 1154 - 1163
  • [39] Accuracy of computer-aided static and dynamic navigation systems in the placement of zygomatic dental implants
    Gonzalez Rueda, Juan Ramon
    Galparsoro Catalan, Agustin
    de Paz Hermoso, Victor Manuel
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Pato Mourelo, Jesus
    Montero Martin, Javier
    Hernandez Montero, Sofia
    BMC ORAL HEALTH, 2023, 23 (01)
  • [40] Modular Preoperative Planning Software for Computer-Aided Oral Implantology and the Application of a Novel Stereolithographic Template: A Pilot Study
    Chen, Xiaojun
    Yuan, Jianbing
    Wang, Chengtao
    Huang, Yuanliang
    Kang, Lu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (03) : 181 - 193