Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study

被引:14
|
作者
Chang, Rai-Jei [1 ]
Chen, Hui-Ling [2 ,4 ]
Huang, Liang-Gie [1 ]
Wong, Yong-Kie [3 ,4 ]
机构
[1] Taichung Vet Gen Hosp, Dept Stomatol, Div Endodont & Periodontol, Taichung, Taiwan
[2] Taichung Vet Gen Hosp, Dept Stomatol, Div Dent Implant, Taichung, Taiwan
[3] Chang Bing Show Chan Mem Hosp, Dept Dent, Div Oral & Maxillofacial Surg, Changhua, Taiwan
[4] Natl Yang Ming Univ, Sch Dent, Taipei, Taiwan
关键词
Accuracy; Computer-aided surgery; Dental implant; IN-VITRO; TECHNOLOGY APPLICATIONS; ORAL IMPLANTS; DENTISTRY; SURGERY; SUCCESS; IMAGES;
D O I
10.1016/j.jcma.2018.04.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A precise positioning for dental implant placement is important for further prosthesis fabrication and maintenance. Computer-aided surgery has been developed to transfer digitally planned implant positioning to the patient over the past decades. This study aimed to evaluate the accuracy of a computer-aided laboratory-fabricated surgical template. A further objective was to compare the accuracy between in vivo and in vitro groups. Methods: A total of 20 implants were placed in the posterior tooth region through the aid of surgical templates on 17 partially edentulous patients in the in vivo group. The surgical template was fabricated in laboratory after virtual implant planning was completed using computer software. In the in vitro group, the same procedures were performed on the models without placing fixture with the same templates used in surgery. Deviations of the implant access at the implant platform level and apical region, as well as the angle deviations between the virtual planning data and the surgical results, were measured using a follow-up Cone Beam Computerized Tomography (CBCT) investigation, and image fusion with planning data. Result: The median deviation at platform level, apex and angulation was 0.95 mm (0.3-1.3 mm), 1.35 mm (0.1-3.6 mm) and 3.92 degrees (0.44-11.66 degrees) respectively in the in vivo group; and 0.4 mm (0-1.0 mm), 0.65 mm (0.1-1.9 mm), 2.16 degrees (0.17-6.91) respectively in the in vitro group. The in vitro group displayed significantly less deviation (p < 0.05). Conclusion: The data from this study shows that computer-aided laboratory-fabricated template may be a reliable tool for implant placement. However, the clinical conditions seem to affect the accuracy of the template. Copyright (C) 2018, the Chinese Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:970 / 976
页数:7
相关论文
共 50 条
  • [21] Accuracy of dental implant placement with computer-guided surgery: a retrospective cohort study
    Ku, Jeong-Kui
    Lee, Junggon
    Lee, Hyo-Jung
    Yun, Pil-Young
    Kim, Young-Kyun
    BMC ORAL HEALTH, 2022, 22 (01)
  • [22] Methods Used to Assess the 3D Accuracy of Dental Implant Positions in Computer-Guided Implant Placement: A Review
    Pyo, Se-Wook
    Lim, Young-Jun
    Koo, Ki-Tae
    Lee, Jungwon
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (01)
  • [23] Accuracy of Surgical Outcome Using Computer-Aided Surgical Simulation in Fronto-Orbital Advancement for Craniosynostosis: A Pilot Study
    Recker, Matthew J.
    Barber, Joshua C.
    Xia, James J.
    Markiewicz, Michael R.
    Kuang, Tianshu
    Deng, Hannah H.
    Singh, Tanya
    Reynolds, Renee M.
    OPERATIVE NEUROSURGERY, 2024, 26 (01) : 46 - 53
  • [24] Guided Implant Placement Using an Internally Cooling Surgical Template: A Technical Note
    Alevizakos, Vasilios
    Mitov, Gergo
    von See, Constantin
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (05) : 533 - 536
  • [25] The accuracy of computer-aided design and manufacturing surgical-guide for infrazygomatic crest miniscrew placement
    Jariyapongpaiboon, Prajak
    Chartpitak, Jirawan
    Jitsaard, Jaturong
    APOS TRENDS IN ORTHODONTICS, 2021, 11 (01) : 48 - 55
  • [26] Accuracy and operation procedure of robotic computer-aided implant surgery
    Liu, Yitian
    Zheng, Qingqing
    Xu, Zonghe
    Lin, Yanjun
    Zhang, Sihui
    Huang, Wenxiu
    Chen, Jiang
    Wu, Dong
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [27] ACCURACY OF IMPLANT PLACEMENT IN THE POSTERIOR MAXILLA AS RELATED TO 2 TYPES OF SURGICAL GUIDES: A PILOT STUDY IN THE HUMAN CADAVER
    Noharet, Renaud
    Pettersson, Andreas
    Bourgeois, Denis
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03) : 526 - 532
  • [28] Trephination-based, guided surgical implant placement: A clinical study
    Suriyan, Nawakamon
    Sarinnaphakorn, Lertrit
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03) : 411 - 416
  • [29] Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement
    Sharma, Shruti
    Tan, Emilie
    Tran, Britney
    Siow, Hui Y.
    Tafesse, Elshadaie
    Thong, Yoong H. J.
    Tan, Row J. M.
    Son, Jungwoo
    Todaro, Lisa
    Teo, Josephine
    Abduo, Jaafar
    JOURNAL OF ORAL SCIENCE, 2024, 66 (01) : 20 - 25
  • [30] Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study
    Feng, Yuzhang
    Su, Zhenya
    Mo, Anchun
    Yang, Xingmei
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)