Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study

被引:14
|
作者
Chang, Rai-Jei [1 ]
Chen, Hui-Ling [2 ,4 ]
Huang, Liang-Gie [1 ]
Wong, Yong-Kie [3 ,4 ]
机构
[1] Taichung Vet Gen Hosp, Dept Stomatol, Div Endodont & Periodontol, Taichung, Taiwan
[2] Taichung Vet Gen Hosp, Dept Stomatol, Div Dent Implant, Taichung, Taiwan
[3] Chang Bing Show Chan Mem Hosp, Dept Dent, Div Oral & Maxillofacial Surg, Changhua, Taiwan
[4] Natl Yang Ming Univ, Sch Dent, Taipei, Taiwan
关键词
Accuracy; Computer-aided surgery; Dental implant; IN-VITRO; TECHNOLOGY APPLICATIONS; ORAL IMPLANTS; DENTISTRY; SURGERY; SUCCESS; IMAGES;
D O I
10.1016/j.jcma.2018.04.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A precise positioning for dental implant placement is important for further prosthesis fabrication and maintenance. Computer-aided surgery has been developed to transfer digitally planned implant positioning to the patient over the past decades. This study aimed to evaluate the accuracy of a computer-aided laboratory-fabricated surgical template. A further objective was to compare the accuracy between in vivo and in vitro groups. Methods: A total of 20 implants were placed in the posterior tooth region through the aid of surgical templates on 17 partially edentulous patients in the in vivo group. The surgical template was fabricated in laboratory after virtual implant planning was completed using computer software. In the in vitro group, the same procedures were performed on the models without placing fixture with the same templates used in surgery. Deviations of the implant access at the implant platform level and apical region, as well as the angle deviations between the virtual planning data and the surgical results, were measured using a follow-up Cone Beam Computerized Tomography (CBCT) investigation, and image fusion with planning data. Result: The median deviation at platform level, apex and angulation was 0.95 mm (0.3-1.3 mm), 1.35 mm (0.1-3.6 mm) and 3.92 degrees (0.44-11.66 degrees) respectively in the in vivo group; and 0.4 mm (0-1.0 mm), 0.65 mm (0.1-1.9 mm), 2.16 degrees (0.17-6.91) respectively in the in vitro group. The in vitro group displayed significantly less deviation (p < 0.05). Conclusion: The data from this study shows that computer-aided laboratory-fabricated template may be a reliable tool for implant placement. However, the clinical conditions seem to affect the accuracy of the template. Copyright (C) 2018, the Chinese Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:970 / 976
页数:7
相关论文
共 50 条
  • [1] Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study
    Beretta, Mario
    Poli, Pier Paolo
    Maiorana, Carlo
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2014, 44 (04): : 184 - 193
  • [2] Accuracy of computer-aided implant placement
    Van Assche, N.
    Vercruyssen, M.
    Coucke, W.
    Teughels, W.
    Jacobs, R.
    Quirynen, M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 : 112 - 123
  • [3] Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement
    Geng, Wei
    Liu, Changying
    Su, Yucheng
    Li, Jun
    Zhou, Yanmin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (06): : 8442 - 8449
  • [4] 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Rudolph, Heike
    Dreyhaupt, Jens
    Luthardt, Ralph G.
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (06) : 2363 - 2372
  • [5] Accuracy of a Computer-Aided Implant Surgical Technique
    Cassetta, Michele
    Stefanelli, Luigi V.
    Giansanti, Matteo
    Di Mambro, Alfonso
    Calasso, Sabrina
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2013, 33 (03) : 317 - 326
  • [6] Accuracy of a computerized tomography-guided template-assisted implant placement system: an in vitro study
    Horwitz, Jacob
    Zuabi, Otman
    Machtei, Eli E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) : 1156 - 1162
  • [7] Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study
    Mediavilla Guzman, Alfonso
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Agustin-Panadero, Ruben
    Hernandez Montero, Sofia
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (12)
  • [8] Digital Evaluation of the Accuracy of Computer-Guided Dental Implant Placement: An In Vitro Study
    Kim, Seong-Min
    Son, Keunbada
    Kim, Duk-Yeon
    Lee, Kyu-Bok
    APPLIED SCIENCES-BASEL, 2019, 9 (16):
  • [9] Accuracy of Implant Placement with a Stereolithographic Surgical Template
    Cassetta, Michele
    Stefanelli, Luigi V.
    Giansanti, Matteo
    Calasso, Sabrina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (03) : 655 - 663
  • [10] Accuracy of a Computer-Aided Dynamic Navigation System in the Placement of Zygomatic Dental Implants: An In Vitro Study
    Gonzalez Rueda, Juan Ramon
    Garcia Avila, Irene
    de Paz Hermoso, Victor Manuel
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Pato Mourelo, Jesus
    Montero Martin, Javier
    Hernandez Montero, Sofia
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)