Clinical Feasibility of Accelerated, High Spatial Resolution Myocardial Perfusion Imaging

被引:28
作者
Manka, Robert [1 ,2 ]
Vitanis, Viton [1 ]
Boesiger, Peter [1 ]
Flammer, Andreas J. [3 ]
Plein, Sven [4 ]
Kozerke, Sebastian [1 ]
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] German Heart Inst, Dept Internal Med Cardiol, Berlin, Germany
[3] Univ Zurich Hosp, Dept Cardiol, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[4] Univ Leeds, Div Cardiovasc & Neuronal Remodelling, Leeds Gen Infirm, Leeds, W Yorkshire, England
基金
英国惠康基金;
关键词
coronary artery disease; ischemia; cardiac magnetic resonance; myocardial perfusion; k-t SENSE; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR MAGNETIC-RESONANCE; K-T SENSE; NONINVASIVE DETECTION; MRI; RECONSTRUCTION; ANGIOGRAPHY; ACQUISITION; TOMOGRAPHY; SPACE;
D O I
10.1016/j.jcmg.2010.03.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to assess the clinical feasibility and diagnostic performance of an acceleration technique based on k-space and time (k-t) sensitivity encoding (SENSE) for rapid, high-spatial resolution cardiac magnetic resonance (CMR) myocardial perfusion imaging. BACKGROUND The assessment of myocardial perfusion is of crucial importance in the evaluation of patients with known or suspected coronary artery disease. CMR myocardial perfusion imaging performs favorably compared to single photon-emission computed tomography and offers higher spatial resolution, particularly when combined with scan acceleration techniques such as k-t SENSE. A previous study showed that k-t SENSE accelerated myocardial perfusion CMR with 5-fold acceleration is feasible and delivers high diagnostic accuracy for the detection of coronary artery disease. Higher acceleration factors have not been attempted clinically because of concerns over temporal blurring effects of the time-varying signal during contrast bolus passage. METHODS Twenty patients underwent myocardial perfusion CMR imaging using a 3.0-T whole-body CMR imager before diagnostic X-ray coronary angiography. Perfusion images were obtained using an extension of the k-t SENSE method using parallel imaging to double the spatial resolution of the k-t SENSE training images. This extension, termed k-t SENSE+, permitted 8-fold nominal scan acceleration and an in-plane spatial resolution of up to 1.1 x 1.1 mm(2). Perfusion scores were derived by 2 blinded observers for 16 myocardial segments and compared to quantitative analysis of X-ray coronary angiography. RESULTS CMR data were successfully obtained in all 20 patients. High diagnostic accuracy was achieved using CMR, as reflected by areas under the receiver-operator characteristic curve of 0.94 and 0.82 for detecting stenoses >50% and >75%, respectively. Observer agreement between 2 readers had a kappa value of 0.92. The areas under the receiver-operator characteristic curves for the left anterior descending, left circumflex, and right coronary artery territories with stenoses >50% were 0.75, 0.92, and 0.79, respectively. CONCLUSIONS Accelerated CMR perfusion imaging is clinically feasible and offers excellent diagnostic performance in detecting coronary stenosis. (J Am Coll Cardiol Img 2010;3:710-7) (c) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:710 / 717
页数:8
相关论文
共 31 条
[1]   Temporally constrained reconstruction of dynamic cardiac perfusion MRI [J].
Adluru, Ganesh ;
Awate, Suyash P. ;
Tasdizen, Tolga ;
Whitaker, Ross T. ;
DiBella, Edward V. R. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1027-1036
[2]   Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance [J].
Al-Saadi, N ;
Nagel, E ;
Gross, M ;
Bornstedt, A ;
Schnackenburg, B ;
Klein, C ;
Klimek, W ;
Oswald, H ;
Fleck, E .
CIRCULATION, 2000, 101 (12) :1379-1383
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[5]   Cardiovascular magnetic resonance perfusion imaging at 3-Tesla for the detection of coronary artery disease - A comparison with 1.5-Tesla [J].
Cheng, Adrian S. H. ;
Pegg, Tammy J. ;
Karamitsos, Theodoros D. ;
Searle, Nick ;
Jerosch-Herold, Michael ;
Choudhury, Robin P. ;
Adrian, P. Banning ;
Neubauer, Stefan ;
Robson, Matthew D. ;
Selvanayagam, Joseph B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (25) :2440-2449
[6]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[7]   On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies [J].
Di Bella, EVR ;
Parker, DL ;
Sinusas, AJ .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1295-1299
[8]  
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
[9]  
2-9
[10]   MR myocardial perfusion Imaging with k-space and time broad-use linear acquisition speed-up technique: Feasibility study [J].
Gebker, Rolf ;
Jahnke, Cosima ;
Paetsch, Ingo ;
Schnackenburg, Bernhard ;
Kozerke, Sebastian ;
Bornstedt, Axel ;
Fleck, Eckart ;
Nagel, Eike .
RADIOLOGY, 2007, 245 (03) :863-871