Resorption behaviour of the articular surface dome and functional outcome after open reduction and internal fixation of mandibular condylar head fractures using small-fragment positional screws

被引:31
作者
Smolka, Wenko [1 ]
Cornelius, Carl-Peter [1 ]
Lechler, Carolin [1 ]
机构
[1] Univ Munich, LMU, Dept Oral & Maxillofacial Surg, Munich, Germany
关键词
Condylar head fracture; Open reduction; Internal fixation; Resorption; CLOSED TREATMENT; MULTICENTER; BONE;
D O I
10.1016/j.jcms.2018.09.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the study was to evaluate the resorption of the mandibular condylar head after open reduction and internal fixation of fractures with small-fragment screws and to evaluate the functional outcome. Patients and method: Forty-eight patients (55 condylar head fractures) underwent surgical treatment. All kinds of complications were recorded. In a subgroup of 20 patients, the average loss of bone height of the condylar head joint surface was gauged by measuring the vertical distances from 3 selected reference points of the fixation hardware to the vertex of the condyle in views of multiplanar radiographs after 6 months. Functional outcome was analysed by Helkimo index score. Results: Complication rates were low. Osteosynthesis loosening occurred in 4 cases. The mean bone resorption along the condylar head joint surface in the subgroup of 20 patients (with 23 joints) was 0.7 mm. Functional outcome was rated as follows: 8 patients - good, 11 patients - slightly impaired, 1 patient - moderately impaired. Conclusion: Open reduction and internal fixation of condylar head fractures with small-fragment screws leads to reliable results in terms of joint surfaces relatively resistant to resorption and function. Low bone resorption on the joint surface of the condylar head can be expected. (C) 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1953 / 1959
页数:7
相关论文
共 23 条
[1]   Surgical Treatment of Adult Mandibular Condylar Fractures Provides Better Outcomes Than Closed Treatment: A Systematic Review and Meta-Analysis [J].
Al-Moraissi, Essam Ahmed ;
Ellis, Edward .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (03) :482-493
[2]   Open versus closed reduction: Diacapitular fractures of the mandibular condyle [J].
Chrcanovic B.R. .
Oral and Maxillofacial Surgery, 2012, 16 (3) :257-265
[3]   Open versus closed treatment of fractures of the mandibular condylar process - a prospective randomized multi-centre study [J].
Eckelt, Uwe ;
Schneider, Matthias ;
Erasmus, Francois ;
Gerlach, Klaus Louis ;
Kuhlisch, Eberhard ;
Loukota, Richard ;
Rasse, Michael ;
Schubert, Johannes ;
Terheyden, Hendrik .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2006, 34 (05) :306-314
[4]   CORRELATIONS OF ELECTRO-MYOGRAPHIC SILENT PERIOD DURATION AND THE HELKIMO DYSFUNCTION INDEX [J].
HELKIMO, MI ;
BAILEY, JO ;
ASH, MM .
ACTA ODONTOLOGICA SCANDINAVICA, 1979, 37 (01) :51-56
[5]   Functional and radiological results of open and closed treatment of intracapsular (diacapitular) condylar fractures of the mandible [J].
Hlawitschka, M ;
Loukota, R ;
Eckelt, U .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (06) :597-604
[6]  
Iizuka T, 1998, J ORAL MAXIL SURG, V56, P553, DOI 10.1016/S0278-2391(98)90450-5
[7]   Surgical reduction and fixation of intracapsular condylar fractures - A follow up study [J].
Kermer, C ;
Undt, G ;
Rasse, M .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 27 (03) :191-194
[8]   Long-term results of ORIF of condylar head fractures of the mandible: A prospective 5-year follow-up study of small-fragment positional-screw osteosynthesis (SFPSO) [J].
Kolk, Andreas ;
Neff, Andreas .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (04) :452-461
[9]   Open Reduction and Internal Fixation of Mandibular Condylar Base and Neck Fractures Using Strut Plates [J].
Lechler, Carolin ;
Probst, Florian ;
Cornelius, Carl-Peter ;
Smolka, Wenko .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (07) :1494-1503
[10]   Behaviour of the buccal crestal bone levels after immediate placement of implants subjected to immediate loading [J].
Lemes, H. deP. ;
Sartori, I. A. deM. ;
Cardoso, L. C. ;
Ponzoni, D. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (03) :389-394