Assessing the influence of meteorological parameters on the performance of polyurethane foam-based passive air samplers

被引:163
作者
Klanova, Jana [1 ]
Eupr, Pavel [1 ]
Kohoutek, Jiri [1 ]
Harner, Tom [2 ]
机构
[1] Masaryk Univ, RECETOX Res Ctr Environm Chem & Ecotoxicol, Brno 62500, Czech Republic
[2] Environm Canada, Atmospher Sci & Technol Div, Toronto, ON M3H 5T4, Canada
关键词
D O I
10.1021/es072098o
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Polyurethane foam (PUF) disk passive air samplers were evaluated under field conditions to assess the effect of temperature and wind speed on the sampling rate for polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and organochlorine pesticides (OCPs). Passive samples integrated over 28-day periods were compared to high-volume air samples collected for 24 h, every 7 days. This provided a large data set of 42 passive sampling events and 168 high-volume samples over a 3-year period, starting in October 2003. Average PUF disk sampling rates for gas-phase chemicals was similar to 7 m(3) d(-1) and comparable to previous reports. The high molecular weight PAHs, which are mainly particle-bound, experienced much lower sampling rates of similar to 0.7 m(3) d(-1). This small rate was attributed to the ability of the sampling chamber to filter out coarse particles with only the fine/ultrafine fraction capable of penetration and collection on the PUF disk. Passive sampler-derived data were converted to equivalent air volumes (V-EQ, m(3)) using the high-volume air measurement results. Correlations of V-EQ against meteorological data collected on-site yielded different behavior for gas- and particle-associated compounds. For gas-phase chemicals, sampling rates varied by about a factor of 2 with temperature and wind sped. The higher sampling rates at colder temperatures were explained by the wind effect on sampling rates. Temperature and wind were strongly correlated with the greatest winds at colder temperatures. Mainly particle-phase compounds (namely, the high molecular weight PAHs) had more variable sampling rates. Sampling rates increased greatly at warmer temperatures as the high molecular weight PAH burden was shifted toward the gas phase and subject to higher gas-phase sampling rates. At colder temperatures, sampling rates were reduced as the partitioning of the high molecular weight PAHs was shifted toward the particle phase. The observed wind effect on sampling for the particle-phase compounds is believed to be tied to this strong temperature dependence on phase partitioning and hence sampling rate. For purposes of comparing passive sampler derived data for persistent organic pollutants, the factor of 2 variability observed for mainly gas-phase compounds is deemed to be acceptable in many instances for semiquantitative analysis. Depuration compounds may be used to improve accuracy and provide site-specific sampling rates, although this adds a level of complexity to the analysis. More research is needed to develop and test passive air samplers for particle-associated chemicals.
引用
收藏
页码:550 / 555
页数:6
相关论文
共 37 条
[1]  
AAS W, 2006, HEAVY METALS POP MEA
[2]   Field-based evaluation of semipermeable membrane devices (SPMDs) as passive air samplers of polyaromatic hydrocarbons (PAHs) [J].
Bartkow, ME ;
Huckins, JN ;
Müller, JF .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (35) :5983-5990
[3]   Characterizing uptake kinetics of PAHs from the air using polyethylene-based passive air samplers of multiple surface area-to-volume ratios [J].
Bartkow, ME ;
Hawker, DW ;
Kennedy, KE ;
Müller, JF .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (09) :2701-2706
[4]  
BIDLEMAN TF, 2000, PROPERTY ESTIMATION
[5]   Passive air sampler as a tool for long-term air pollution monitoring:: Part 2.: Air genotoxic potency screening assessment [J].
Cupr, Pavel ;
Klanova, Jana ;
Bartos, Tomas ;
Flegrova, Zuzana ;
Kohoutek, Jiri ;
Holoubek, Ivan .
ENVIRONMENTAL POLLUTION, 2006, 144 (02) :406-413
[6]   Continental scale passive air sampling of persistent organic pollutants using rapidly equilibrating thin films (POGs) [J].
Farrar, Nick J. ;
Prevedouros, Konstantinos ;
Harner, Tom ;
Sweetman, Andrew J. ;
Jones, Kevin C. .
ENVIRONMENTAL POLLUTION, 2006, 144 (02) :423-433
[7]   Field deployment of thin film passive air samplers for persistent organic pollutants: A study in the urban atmospheric boundary layer [J].
Farrar, NJ ;
Harner, T ;
Shoeib, M ;
Sweetman, A ;
Jones, KC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (01) :42-48
[8]   Passive and active air samplers as complementary methods for investigating persistent organic pollutants in the Great Lakes basin [J].
Gouin, T ;
Harner, T ;
Blanchard, P ;
Mackay, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (23) :9115-9122
[9]   Variability of concentrations of polybrominated diphenyl ethers and polychlorinated biphenyls in air: implications for monitoring, modeling and control [J].
Gouin, T ;
Harner, T ;
Daly, GL ;
Wania, F ;
Mackay, D ;
Jones, KC .
ATMOSPHERIC ENVIRONMENT, 2005, 39 (01) :151-166
[10]   Using passive air samplers to assess urban - Rural trends for persistent organic pollutants. 1. Polychlorinated biphenyls and organochlorine pesticides [J].
Harner, T ;
Shoeib, M ;
Diamond, M ;
Stern, G ;
Rosenberg, B .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (17) :4474-4483