摘要
Photoacoustic (PA) signals are short ultrasound (US) pulses typically characterized by a single-cycle shape, often referred to as N-shape. The spectral content of such wideband signals ranges from a few hundred kilohertz to several tens of megahertz. Typical reception frequency responses of classical piezoelectric US imaging transducers, based on PZT technology, are not sufficiently broadband to fully preserve the entire information contained in PA signals, which are then filtered, thus limiting PA imaging performance. Capacitive micromachined ultrasonic transducers (CMUT) are rapidly emerging as a valid alternative to conventional PZT transducers in several medical ultrasound imaging applications. As compared to PZT transducers, CMUTs exhibit both higher sensitivity and significantly broader frequency response in reception, making their use attractive in PA imaging applications. This paper explores the advantages of the CMUT larger bandwidth in PA imaging by carrying out an experimental comparative study using various CMUT and PZT probes from different research laboratories and manufacturers. PA acquisitions are performed on a suture wire and on several home-made bimodal phantoms with both PZT and CMUT probes. Three criteria, based on the evaluation of pure receive impulse response, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) respectively, have been used for a quantitative comparison of imaging results. The measured fractional bandwidths of the CMUT arrays are larger compared to PZT probes. Moreover, both SNR and CNR are enhanced by at least 6 dB with CMUT technology. This work highlights the potential of CMUT technology for PA imaging through qualitative and quantitative parameters. (C) 2017 The Authors. Published by Elsevier GmbH.
引用
收藏
页码:48 / 58
页数:11
相关论文
共 28 条
[1]   PECVD low stress silicon nitride analysis and optimization for the fabrication of CMUT devices [J].
Bagolini, Alvise ;
Savoia, Alessandro Stuart ;
Picciotto, Antonino ;
Boscardin, Maurizio ;
Bellutti, Pierluigi ;
Lamberti, Nicola ;
Caliano, Giosue .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2015, 25 (01)
[2]   Low temperature capacitive micromachined ultrasonic transducers (cMUTs) on glass substrate [J].
Bahette, E. ;
Michaud, J. F. ;
Certon, D. ;
Gross, D. ;
Perroteau, M. ;
Alquier, D. .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (11)
[3]   3-D photoacoustic and pulse echo imaging of prostate tumor progression in the mouse window chamber [J].
Bauer, Daniel R. ;
Olafsson, Ragnar ;
Montilla, Leonardo G. ;
Witte, Russell S. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (02)
[4]  
Bell Graham A., 1880, J SOC TELEGR ENG, V34, P404, DOI [10.1049/jste-1.1880.0046, DOI 10.1049/JSTE-1.1880.0046]
[5]   A Reconfigurable and Programmable FPGA-Based System for Nonstandard Ultrasound Methods [J].
Boni, Enrico ;
Bassi, Luca ;
Dallai, Alessandro ;
Guidi, Francesco ;
Ramalli, Alessandro ;
Ricci, Stefano ;
Housden, James ;
Tortoli, Piero .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) :1378-1385
[6]   A Photoacoustic Imager With Light Illumination Through an Infrared-Transparent Silicon CMUT Array [J].
Chen, Jingkuang ;
Wang, Mengli ;
Cheng, Jui-Ching ;
Wang, Yu-Hsin ;
Li, Pai-Chi ;
Cheng, Xiaoyang .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) :766-775
[7]   Functional optoacoustic human angiography with handheld video rate three dimensional scanner [J].
Dean-Ben, Xose Luis ;
Razansky, Daniel .
PHOTOACOUSTICS, 2013, 1 (3-4) :68-73
[8]   PHOTOACOUSTIC MONOPOLE RADIATION IN 1-DIMENSION, 2-DIMENSION, AND 3-DIMENSION [J].
DIEBOLD, GJ ;
SUN, T ;
KHAN, MI .
PHYSICAL REVIEW LETTERS, 1991, 67 (24) :3384-3387
[9]   Characterization of one-dimensional capacitive micromachined ultrasonic immersion transducer arrays [J].
Jin, XC ;
Oralkan, Ö ;
Degertekin, FL ;
Khuri-Yakub, BT .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (03) :750-760
[10]   Low temperature fabrication of immersion capacitive micromachined ultrasonic transducers on silicon and dielectric substrates [J].
Knight, J ;
McLean, J ;
Degertekin, FL .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (10) :1324-1333