Efficient immobilization of a cadmium chemosensor in a thin film: Generation of a cadmium sensor prototype

被引:123
作者
Bronson, RT [1 ]
Michaelis, DJ
Lamb, RD
Husseini, GA
Farnsworth, PB
Linford, MR
Izatt, RM
Bradshaw, JS
Savage, PB
机构
[1] Coll So Idaho, Dept Phys Sci, Bratislava 83301, Slovakia
[2] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
关键词
D O I
10.1021/ol050027t
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
The development of an ion-selective chemosensor for Cd2+ allows generation of a "real-time" sensor, Immobilization of the chemosensor on quartz was achieved in a simple monolayer and in a thin film using a polymer intermediary. As intended, the thin film contains much more chemosensor than the monolayer and provides measurable responses to aqueous Cd2+ concentrations below 1 mu M. Alkali and alkaline earth ions do not interfere with Cd2+ sensing; Zn2+ and Cu2+ are potential interferents.
引用
收藏
页码:1105 / 1108
页数:4
相关论文
共 18 条
[11]  
Nordberg G.F., 1992, CADMIUM HUMAN ENV
[12]   Luminescent chemosensors for transition metal ions [J].
Prodi, L ;
Bolletta, F ;
Montalti, M ;
Zaccheroni, N .
COORDINATION CHEMISTRY REVIEWS, 2000, 205 :59-83
[13]   Characterization of 5-chloro-8-methoxyquinoline appended diaza-18-crown-6 as a chemosensor for cadmium [J].
Prodi, L ;
Montalti, M ;
Zaccheroni, N ;
Bradshaw, JS ;
Izatt, RM ;
Savage, PB .
TETRAHEDRON LETTERS, 2001, 42 (16) :2941-2944
[14]   A global perspective on cadmium pollution and toxicity in non-occupationally exposed population [J].
Satarug, S ;
Baker, JR ;
Urbenjapol, S ;
Haswell-Elkins, M ;
Reilly, PEB ;
Williams, DJ ;
Moore, MR .
TOXICOLOGY LETTERS, 2003, 137 (1-2) :65-83
[15]   Exploiting flow injection and sequential injection anodic stripping voltammetric systems for simultaneous determination of some metals [J].
Suteerapataranon, S ;
Jakmunee, J ;
Vaneesorn, Y ;
Grudpan, K .
TALANTA, 2002, 58 (06) :1235-1242
[16]   Design principles of fluorescent molecular sensors for cation recognition [J].
Valeur, B ;
Leray, I .
COORDINATION CHEMISTRY REVIEWS, 2000, 205 :3-40
[17]   Monolayer of a Na+-selective fluoroionophore on glass:: Connecting the fields of monolayers and optical detection of metal ions [J].
van der Veen, NJ ;
Flink, S ;
Deij, MA ;
Egberink, RJM ;
van Veggel, FCJM ;
Reinhoudt, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (25) :6112-6113
[18]   Determination of cadmium in water by ICP-AES with on-line adsorption preconcentration using DPTH-gel and TS-gel microcolumns [J].
Zougagh, M ;
de Torres, AG ;
Pavón, JMC .
TALANTA, 2002, 56 (04) :753-761