Detecting and Discriminating Shigella sonnei Using an Aptamer-Based Fluorescent Biosensor Platform

被引:65
作者
Song, Myeong-Sub [1 ]
Sekhon, Simranjeet Singh [1 ]
Shin, Woo-Ri [1 ]
Kim, Hyung Cheol [2 ]
Min, Jiho [3 ]
Ahn, Ji-Young [1 ]
Kim, Yang-Hoon [1 ]
机构
[1] Chungbuk Natl Univ, Sch Biol Sci, 1 Chungdae Ro, Cheongju 28644, South Korea
[2] Korea Res Inst Biosci & Biotechnol, Technol Transfer Ctr, 125 Gwahak Ro, Daejeon 34141, South Korea
[3] Chonbuk Natl Univ, Dept Bioproc Engn, 567 Baekje Daero, Jeonju 54896, South Korea
关键词
shigellosis; aptamer-based fluorescent biosensor; whole cell-SELEX; DNA aptamer; ESCHERICHIA-COLI; SALMONELLA-ENTERICA; GENE; IDENTIFICATION; PRODUCTS; OUTBREAK; ASSAY; SPP;
D O I
10.3390/molecules22050825
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, a Whole-Bacteria SELEX (WB-SELEX) strategy was adopted to isolate specific aptamers against Shigella sonnei. Real-time PCR amplification and post-SELEX experiment revealed that the selected aptmers possessed a high binding affinity and specificity for S. sonnei. Of the 21 aptamers tested, the C(t) values of the SS-3 and SS-4 aptamers (Ct = 13.89 and Ct = 12.23, respectively) had the lowest value compared to other aptamer candidates. The SS-3 and SS-4 aptamers also displayed a binding affinity (K-D) of 39.32 +/- 5.02 nM and 15.89 +/- 1.77 nM, respectively. An aptamer-based fluorescent biosensor assay was designed to detect and discriminate S. sonnei cells using a sandwich complex pair of SS-3 and SS-4. The detection of S. sonnei by the aptamer based fluorescent biosensor platform consisted of three elements: (1) 5'amine-SS-4 modification in a 96-well type microtiter plate surface (N-oxysuccinimide, NOS) as capture probes; (2) the incubation with S. sonnei and test microbes in functionalized 96 assay wells in parallel; (3) the readout of fluorescent activity using a Cy5-labeled SS-3 aptamer as the detector. Our platform showed a significant ability to detect and discriminate S. sonnei from other enteric species such as E. coli, Salmonella typhimurium and other Shigella species (S. flexneri, S. boydii). In this study, we demonstrated the feasibility of an aptamer sensor platform to detect S. sonnei in a variety of foods and pave the way for its use in diagnosing shigellosis through multiple, portable designs.
引用
收藏
页数:12
相关论文
共 50 条
[41]   A Novel Approach for Designing Electrochemical Aptamer-Based Biosensor for Ultrasensitive Detection of Zearalenone as a Prevalent Estrogenic Mycotoxin [J].
Hassani, Shokoufeh ;
Maghsoudi, Armin Salek ;
Akmal, Milad Rezaei ;
Shoeibi, Shahram ;
Ghadipasha, Fatemeh ;
Mousavi, Taraneh ;
Ganjali, Mohammad Reza ;
Hosseini, Rohollah ;
Abdollahi, Mohammad .
CURRENT MEDICINAL CHEMISTRY, 2022, 29 (37) :5881-5894
[42]   Aptamer-based microcantilever-array biosensor for ultra-sensitive and rapid detection of okadaic acid [J].
Wang, Yu ;
Rao, Depeng ;
Wu, Xiaoping ;
Zhang, Qingchuan ;
Wu, Shangquan .
MICROCHEMICAL JOURNAL, 2021, 160
[43]   Aptamer-based electrochemical biosensor for highly sensitive and selective malaria detection with adjustable dynamic response range and reusability [J].
Figueroa-Miranda, Gabriela ;
Feng, Lingyan ;
Shiu, Simon Chi-Chin ;
Dirkzwager, Roderick Marshall ;
Cheung, Yee-Wai ;
Tanner, Julian Alexander ;
Schoening, Michael Josef ;
Offenhaeusser, Andreas ;
Mayer, Dirk .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 :235-243
[44]   Aptamer-based arrayed microneedle biosensor to monitor C-reactive protein for cardiovascular diseases risk assessment [J].
Chang, Sung-Chi ;
Wang, Chih-Hung ;
Cheng, Kuang-Hung ;
Lee, Gwo-Bin .
SENSORS AND ACTUATORS B-CHEMICAL, 2025, 440
[45]   A Biosensor Platform for Metal Detection Based on Enhanced Green Fluorescent Protein [J].
Lee, Woonwoo ;
Kim, Hyojin ;
Kang, Yerin ;
Lee, Youngshim ;
Yoon, Youngdae .
SENSORS, 2019, 19 (08)
[46]   Aptamer-based fluorometric determination of norovirus using a paper-based microfluidic device [J].
Weng, Xuan ;
Neethirajan, Suresh .
MICROCHIMICA ACTA, 2017, 184 (11) :4545-4552
[47]   A Simple Label-Free Aptamer-Based Electrochemical Biosensor for the Sensitive Detection of C-Reactive Proteins [J].
Gao, Huilin ;
Bai, Yongchang ;
He, Baixun ;
Tan, Cherie S. .
BIOSENSORS-BASEL, 2022, 12 (12)
[48]   Aptamer-based PDMS-gold nanoparticle composite as a platform for visual detection of biomolecules with silver enhancement [J].
Wang, Wei ;
Wu, Wen-Ya ;
Zhong, Xiaoqin ;
Wang, Wei ;
Miao, Qiang ;
Zhu, Jun-Jie .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (07) :3110-3114
[49]   Respective and simultaneous detection tumor markers CA125 and STIP1 using aptamer-based fluorescent and RLS sensors [J].
Chen, Feng ;
Liu, Yi ;
Chen, Chunyan ;
Gong, Hang ;
Cai, Changqun ;
Chen, Xiaoming .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 245 :470-476
[50]   Research progress in fluorescent biosensor technology for detecting Escherichia coli based on PCR [J].
Guo, Wenjin ;
Li, Qian ;
Yang, Xinran ;
Xu, Pengbo ;
Cai, Gaozhe ;
Cui, Chuanjin .
SENSOR REVIEW, 2024, 44 (06) :682-695