Detecting and Discriminating Shigella sonnei Using an Aptamer-Based Fluorescent Biosensor Platform

被引:62
作者
Song, Myeong-Sub [1 ]
Sekhon, Simranjeet Singh [1 ]
Shin, Woo-Ri [1 ]
Kim, Hyung Cheol [2 ]
Min, Jiho [3 ]
Ahn, Ji-Young [1 ]
Kim, Yang-Hoon [1 ]
机构
[1] Chungbuk Natl Univ, Sch Biol Sci, 1 Chungdae Ro, Cheongju 28644, South Korea
[2] Korea Res Inst Biosci & Biotechnol, Technol Transfer Ctr, 125 Gwahak Ro, Daejeon 34141, South Korea
[3] Chonbuk Natl Univ, Dept Bioproc Engn, 567 Baekje Daero, Jeonju 54896, South Korea
来源
MOLECULES | 2017年 / 22卷 / 05期
关键词
shigellosis; aptamer-based fluorescent biosensor; whole cell-SELEX; DNA aptamer; ESCHERICHIA-COLI; SALMONELLA-ENTERICA; GENE; IDENTIFICATION; PRODUCTS; OUTBREAK; ASSAY; SPP;
D O I
10.3390/molecules22050825
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, a Whole-Bacteria SELEX (WB-SELEX) strategy was adopted to isolate specific aptamers against Shigella sonnei. Real-time PCR amplification and post-SELEX experiment revealed that the selected aptmers possessed a high binding affinity and specificity for S. sonnei. Of the 21 aptamers tested, the C(t) values of the SS-3 and SS-4 aptamers (Ct = 13.89 and Ct = 12.23, respectively) had the lowest value compared to other aptamer candidates. The SS-3 and SS-4 aptamers also displayed a binding affinity (K-D) of 39.32 +/- 5.02 nM and 15.89 +/- 1.77 nM, respectively. An aptamer-based fluorescent biosensor assay was designed to detect and discriminate S. sonnei cells using a sandwich complex pair of SS-3 and SS-4. The detection of S. sonnei by the aptamer based fluorescent biosensor platform consisted of three elements: (1) 5'amine-SS-4 modification in a 96-well type microtiter plate surface (N-oxysuccinimide, NOS) as capture probes; (2) the incubation with S. sonnei and test microbes in functionalized 96 assay wells in parallel; (3) the readout of fluorescent activity using a Cy5-labeled SS-3 aptamer as the detector. Our platform showed a significant ability to detect and discriminate S. sonnei from other enteric species such as E. coli, Salmonella typhimurium and other Shigella species (S. flexneri, S. boydii). In this study, we demonstrated the feasibility of an aptamer sensor platform to detect S. sonnei in a variety of foods and pave the way for its use in diagnosing shigellosis through multiple, portable designs.
引用
收藏
页数:12
相关论文
共 50 条
[21]   Aptamer-based microcantilever array biosensor for detection of fumonisin B-1 [J].
Chen, Xuejuan ;
Bai, Xiaojing ;
Li, Huiyan ;
Zhang, Bailin .
RSC ADVANCES, 2015, 5 (45) :35448-35452
[22]   A hairpin aptamer-based electrochemical biosensing platform for the sensitive detection of proteins [J].
Wu, Zai-Sheng ;
Zheng, Fan ;
Shen, Guo-Li ;
Yu, Ru-Qin .
BIOMATERIALS, 2009, 30 (15) :2950-2955
[23]   Aptamer-based electrochemical analysis platform for tumor cells and biomarkers detection [J].
Wang, Yihan ;
Yao, Wenyan ;
Sun, Wenyu ;
Fan, Yingying ;
Xiao, Jiang ;
Wang, Tingya ;
Huang, Ke ;
Liu, Liu ;
Wang, Xuemei ;
Jiang, Hui .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 960
[24]   Aptamer-Based Fluorescent Determination of Salmonella paratyphi A Using Phi29-DNA Polymerase-Assisted Cyclic Amplification [J].
Liang, Jingjing ;
Zhou, Jiaqi ;
Tan, Jianxi ;
Wang, Zefeng ;
Deng, Le .
ANALYTICAL LETTERS, 2019, 52 (06) :919-931
[25]   Enzymatic cleavage and mass amplification strategy for small molecule detection using aptamer-based fluorescence polarization biosensor [J].
Kang, Liping ;
Yang, Bin ;
Zhang, Xiaobing ;
Cui, Liang ;
Meng, Hongmin ;
Mei, Lei ;
Wu, Cuichen ;
Ren, Songlei ;
Tan, Weihong .
ANALYTICA CHIMICA ACTA, 2015, 879 :91-96
[26]   Label-Free Aptamer-Based Biosensor for Specific Detection of Chloramphenicol Using AIE Probe and Graphene Oxide [J].
Zhang, Song ;
Ma, Lian ;
Ma, Ke ;
Xu, Bin ;
Liu, Leijing ;
Tian, Wenjing .
ACS OMEGA, 2018, 3 (10) :12886-12892
[27]   A simple aptamer-based fluorescent aflatoxin B1 sensor using humic acid as quencher [J].
Guo, Manli ;
Hou, Qin ;
Waterhouse, Geoffrey I. N. ;
Hou, Juying ;
Ai, Shiyun ;
Li, Xiangyang .
TALANTA, 2019, 205
[28]   Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine [J].
Yan, Fangfang ;
Wang, Fang ;
Chen, Zilin .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) :1380-1385
[29]   Aptamer-based Dry-reagent Strip Biosensor for Detection of Small Molecule ATP [J].
Zhang, Qiang ;
Qiu, Hongbin ;
Tang, Fangqiang ;
Tao, Ye ;
Guan, Baosheng ;
Li, Xuechen ;
Yang, Wei .
CHEMISTRY LETTERS, 2016, 45 (03) :289-290
[30]   Microfluidic flow-injection aptamer-based chemiluminescence platform for sulfadimethoxine detection [J].
Wang, Yanwei ;
Rink, Simone ;
Baeumner, Antje J. ;
Seidel, Michael .
MICROCHIMICA ACTA, 2022, 189 (03)