Surface Charge Accumulation and Decay on Direct fluorinated Oil-impregnated Paper

被引:17
作者
Du, B. X. [1 ]
Li, X. L. [1 ]
Jiang, J. P. [1 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Key Lab Smart Grid, Educ Minist, Tianjin 300072, Peoples R China
关键词
transformer; paper; direct-fluorination; surface charge; charge decay; charge accumulation; transformer oil; trap; BEHAVIOR; INSULATION; DC; INTERFACE;
D O I
10.1109/TDEI.2016.7736874
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The oil-impregnated paper, as a vital part in the oil-paper insulation system, serves as the main insulation medium in converter transformer suffering various electric fields. However, the accumulated surface charge on the paper would accelerate the degradation of insulation system and may lead to surface flashover. Direct-fluorination is a method to change the chemical components of polymer matrix thus could affect the surface property of the dielectric material without the alternation of bulk property. This paper presents a method to modify the surface structure of the paper applied in transformers. The paper used in the experiment was treated using the F-2/N-2 mixture with a volume fraction of 10% for the F-2 gas at a pressure of 0.05 MN in a reaction vessel for 2, 5, 10 and 15 min, respectively. The chemical elements, functional group and physical morphology of the paper before and after modification were measured with energy dispersive X-ray spectroscopy (EDAX), attenuated total reflection infrared (ATR-IR) and scanning electron micrographs (SEM), respectively. Surface and volume resistivity of the fluorinated paper were measured. Furthermore, the surface charge property of the oil-impregnated paper was measured under various positive and negative voltages. Obtained results showed that the fluorination had an obvious influence on the chemical property and surface structure of the paper leading to the reduction of surface and volume resistivity. The treatment was shown to reduce the initial potential and cause acceleration in charge decay process. The trap distribution of the paper surface presented alternation as well.
引用
收藏
页码:3094 / 3101
页数:8
相关论文
共 33 条
[1]   Modulation of Surface Electrical Properties of Epoxy Resin Insulator by Changing Fluorination Temperature and Time [J].
An, Zhenlian ;
Yin, Qianqian ;
Liu, Yaqiang ;
Zheng, Feihu ;
Lei, Qingquan ;
Zhang, Yewen .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) :526-534
[2]  
[Anonymous], 2010, A2B428 CIGRE JWG
[3]  
Chen Q. G., 2014, ADV MAT RES, V981, P940, DOI DOI 10.4028/WWW.SCIENTIFIC.NET/AMR.981.940
[4]  
CIGRE, 2000, 1217 CIGRE WG
[5]  
Dean J.A., 2001, Lange's Handbook of Chemistry, V15
[6]   Interface Charge Behavior of Multi-layer Oil-Paper Insulation under DC and Polarity Reversal Voltages [J].
Du, B. X. ;
Zhang, J. G. ;
Liu, D. S. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (05) :2628-2636
[7]   Effects of Surface Fluorination on Dielectric Properties and Surface Charge Behavior of Water Absorbed Polyimide Film [J].
Du, B. X. ;
Guo, Y. G. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (03) :1369-1375
[8]   Surface Charge and DC Flashover Characteristics of Direct-fluorinated SiR/SiO2 Nanocomposites [J].
Du, B. X. ;
Li, Z. L. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) :2602-2610
[9]   Surface Charge Accumulation and Decay of Direct-fluorinated RTV Silicone Rubber [J].
Du, B. X. ;
Li, Z. L. ;
Li, Jie .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (05) :2338-2342
[10]   Effect of Surface Fluorination on Space Charge Behavior in Multilayered Polyimide Films [J].
Du, B. X. ;
Li, Jie ;
Du, Heng ;
Yin, Yi .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) :1817-1823