Contrast-enhanced intraoperative ultrasonography equipped with late Kupffer-phase image obtained by sonazoid in patients with colorectal liver metastases

被引:56
作者
Nakano, Hiroshi [1 ]
Ishida, Yasuo [1 ]
Hatakeyama, Toshiyuki [1 ]
Sakuraba, Kazuma [1 ]
Hayashi, Masahiro [1 ]
Sakurai, Osamu [1 ]
Hataya, Kiyoshi [1 ]
机构
[1] Yokohama Asahi Chuo Gen Hosp, Dept Surg, Asahi Ku, Yokohama, Kanagawa 2410801, Japan
关键词
contrast-enhanced intraoperative ultrasonography; late Kupffer-phase image; sonazoid; colorectal cancer liver metastases; occult hepatic lesions;
D O I
10.3748/wjg.14.3207
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To find occult metastases during hepatectomy in patients with colorectal cancer liver metastases (CRCLM), contrast-enhanced intraoperative ultrasonography (CE-IOUS) was performed using a new microbubble agent, sonazoid, which provides a parenchyma-specific contrast image based on its accumulation in the Kupffer cells. METHODS: Eight patients with CRCLM underwent CE-IOUS using sonazoid before hepatectomy. The liver was investigated during a late Kupffer-phase imaging, which is a valuable characteristic of sonazoid. RESULTS: CE-IOUS using sonazoid provided the early vascular- and sinusoidal-phase images for 10 min followed by the late Kupffer-phase image up to 30 min after the injection of sonazoid. IOUS did not provide new findings of metastatic lesion in the 8 patients. However, during the late Kupffer-phase image of sonazoid, a metastatic lesion was newly found in two of the 8 patients. These newly detected lesions were removed by an additional hepatectomy and histopathologically diagnosed as a metastasis. CONCLUSION: CE-IOUS using sonazoid can allow surgeons to investigate the whole liver with enough time and to find new metastases intraoperatively. (C) 2008 The WJG Press. All rights reserved.
引用
收藏
页码:3207 / 3211
页数:5
相关论文
共 18 条
[1]   Liver resection for colorectal metastases - The third hepatectomy [J].
Adam, R ;
Pascal, G ;
Azoulay, D ;
Tanaka, K ;
Castaing, D ;
Bismuth, H .
ANNALS OF SURGERY, 2003, 238 (06) :871-883
[2]  
Clavien PA, 2003, ANN SURG, V238, P883
[3]   THE ROLE OF OCCULT HEPATIC METASTASES IN STAGING COLORECTAL-CARCINOMA [J].
FINLAY, IG ;
MCARDLE, CS .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1988, 23 :150-154
[4]   Liver resection for colorectal metastases [J].
Fong, YM ;
Cohen, AM ;
Fortner, JG ;
Enker, WE ;
Turnbull, AD ;
Coit, DG ;
Marrero, AM ;
Prasad, M ;
Blumgart, LH ;
Brennan, MF .
JOURNAL OF CLINICAL ONCOLOGY, 1997, 15 (03) :938-946
[5]   Hepatic tumor detection: MR Imaging and conventional US versus pulse-inversion harmonic US of NC100100 during its reticuloendothelial system-specific phase [J].
Forsberg, F ;
Piccoli, CW ;
Liu, JB ;
Rawool, NM ;
Merton, DA ;
Mitchell, DG ;
Goldberg, BB .
RADIOLOGY, 2002, 222 (03) :824-829
[6]  
Hagen EK, 2000, INVEST RADIOL, V35, P118
[7]   One or two-stage hepatectomy combined with portal vein embolization for initially nonresectable colorectal liver metastases [J].
Jaeck, D ;
Bachellier, P ;
Nakano, H ;
Oussoultzoglou, E ;
Weber, JC ;
Wolf, P ;
Greget, M .
AMERICAN JOURNAL OF SURGERY, 2003, 185 (03) :221-229
[8]   What is the yield of intraoperative ultrasonography during partial hepatectomy for malignant disease? [J].
Jarnagin, WR ;
Bach, AM ;
Winston, CB ;
Hann, LE ;
Heffernan, N ;
Loumeau, T ;
DeMatteo, RP ;
Fong, Y ;
Blumgart, LH .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2001, 192 (05) :577-583
[9]   Hepatic clearance of Sonazoid perfluorobutane microbubbles by Kupffer cells does not reduce the ability of liver to phagocytose or degrade albumin microspheres [J].
Kindberg, GM ;
Tolleshaug, H ;
Roos, N ;
Skotland, T .
CELL AND TISSUE RESEARCH, 2003, 312 (01) :49-54
[10]   Mechanism of parenchymal enhancement of the liver with a microbubble-based US contrast medium:: An intravital microscopy study in rats [J].
Kono, Y ;
Steinbach, GC ;
Peterson, T ;
Schmid-Schönbein, GW ;
Mattrey, RF .
RADIOLOGY, 2002, 224 (01) :253-257