Safety of a continuous glucose monitoring device during hyperbaric exposure

被引:0
作者
Bliss, Chae [1 ]
Huang, Enoch [1 ]
Savaser, Davut [1 ]
机构
[1] Legacy Emanuel Hyperbar Med, Portland, OR 97227 USA
关键词
CGM; continuous glucose monitoring; diabetes; glucometer; HBO; hyperbaric device clearance; hyperbaric oxygen therapy; hyperbaric safety;
D O I
暂无
中图分类号
Q17 [水生生物学];
学科分类号
071004 ;
摘要
Background: Hyperbaric oxygen therapy has been demonstrated to lower blood glucose levels in patients with diabetes. Continuous glucose monitoring (CGM) allows glucose monitoring in real time. Battery-operated CGM transmitters have yet to be formally tested and given safety approval for use in a hyperbaric environment. Materials and Methods: We evaluated and tested commercially available Dexcom (R) G6 CGM transmitters under hyperbaric conditions. Each transmitter contains a 3V, 130-mAh (0.39 Wh) lithium manganese dioxide battery (IEC CR1632) and circuit board that are fully encapsulated in epoxy. Each transmitter is pressurized to 90 pounds per square inch (psi) in an autoclave at 40 degrees C for up to 72 hours during manufacturing to ensure that all enclosed air spaces are eliminated from the epoxy. We compared the CGM components against section 14.2.9.3.17.5 of the 2018 National Fire Protection Association 99 (NFPA 99) Health Care Facilities Code requirements. Six CGM transmitters attached to estimated glucose value generators (EGVGs) underwent 11 pressurization cycles to 45 feet of seawater (fsw). All transmitters were returned to the manufacturer to assess post-exposure structural integrity. G6 sensors, which contain no electrical components or compressible air spaces, do not pose a risk in the hyperbaric environment. Results: There was no observed change in preset EGVG readings during hyperbaric exposures. Post-exposure testing revealed no structural compromise after repeated hyperbaric exposures. Conclusions: The CGM transmitter meets section 14.2.9.3.17.5 of the 2018 NFPA 99 requirements for battery-operated devices allowed for use in a hyperbaric environment. This analysis revealed no significant safety concerns with subjecting Dexcom G6 CGM transmitters to hyperbaric environments.
引用
收藏
页码:13 / 19
页数:7
相关论文
共 7 条
[1]   Continuous Glucose Monitoring-A Study of the Enlite Sensor During Hypo- and Hyperbaric Conditions [J].
Adolfsson, Peter ;
Ornhagen, Hans ;
Eriksson, Bengt M. ;
Cooper, Ken ;
Jendle, Johan .
DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (06) :527-532
[2]   Influences of hyperbaric oxygen on blood pressure, heart rate and blood glucose levels in patients with diabetes mellitus and hypertension [J].
Al-Waili, Noori S. ;
Butler, Glenn J. ;
Beale, Jorge ;
Abdullah, Mahdi S. ;
Finkelstein, Michael ;
Merrow, Michael ;
Rivera, Richard ;
Petrillo, Richard ;
Carrey, Zev ;
Lee, Bok ;
Allen, Michael .
ARCHIVES OF MEDICAL RESEARCH, 2006, 37 (08) :991-997
[3]  
[Anonymous], 2019, HYP EXP 2 4 ATM SCOR, P3
[4]  
[Anonymous], 2015, 99 NFPA
[5]  
[Anonymous], 2019, 2D XRAY AN 8 8 TX TR
[6]  
Burman F, 2009, UNDERSEA HYPERBAR M, V36, P137
[7]  
U.S. Food and Drug Administration, 2019, FDA AUTH 1 FULL INT