Sensitive and Simultaneous Detection of Cardiac Markers in Human Serum Using Surface Acoustic Wave Immunosensor

被引:61
作者
Lee, Joonhyung [1 ]
Choi, Youn-Suk [1 ]
Lee, Yeolho [1 ]
Lee, Hun Joo [1 ,2 ]
Lee, Jung Nam [1 ]
Kim, Sang Kyu [1 ]
Han, Kyung Yeon [1 ]
Cho, Eun Chol [1 ]
Park, Jae Chan [1 ]
Lee, Soo Suk [1 ]
机构
[1] Samsung Elect Co Ltd, Bio Lab, Samsung Adv Inst Technol, Yongin, Gyeonggi Do, South Korea
[2] Sogang Univ, Interdisciplinary Program Integrated Biotechnol, Seoul, South Korea
关键词
TROPONIN-I ASSAY; PROTEIN; BIOSENSORS; SENSORS; POINT;
D O I
10.1021/ac2020849
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a rapid and sensitive surface acoustic wave (SAW) immunosensor that utilizes gold staining as a signal enhancement method. A sandwich immunoassay was performed on sensing area of the SAW sensor, which could specifically capture and detect cardiac markers (cardiac troponin I (cTnI), creatine kinase (CK)-MB, and myoglobin). The analytes in human serum were captured on gold nanoparticles (AuNPs) that were conjugated in advance with detection antibodies. Introduction of these complexes to the capture antibody-immobilized sensor surface resulted in a classic AuNP-based sandwich immunoassay format that has been used for signal amplification. In order to achieve further signal enhancement, a gold staining method was performed, which demonstrated that it is possible to obtain gold staining-mediated signal augmentation on a mass-sensitive device. The sensor response due to gold staining varied as a function of cardiac marker concentration. We also investigated effects of increasing operating frequency on sensor responses. Results showed that detection limit of the SAW sensor could be further improved by increasing the operating frequency.
引用
收藏
页码:8629 / 8635
页数:7
相关论文
共 35 条
[1]   Immunomagnetic diffractometry for detection of diagnostic serum markers [J].
Acharya, Ghanashyam ;
Chang, Chun-Li ;
Doorneweerd, Derek D. ;
Vlashi, Erina ;
Henne, Walter A. ;
Hartmann, Lynn C. ;
Low, Philip S. ;
Savran, Cagri A. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (51) :15824-15829
[2]   Love-wave biosensors using cross-linked polymer waveguides on LiTaO3 substrates [J].
Bender, F ;
Cernosek, RW ;
Josse, F .
ELECTRONICS LETTERS, 2000, 36 (19) :1672-1673
[3]   A study of Love wave devices in ZnO/Quartz and ZnO/LiTaO3 structures [J].
Chang, RC ;
Chu, SY ;
Hong, CS ;
Chuang, YT .
THIN SOLID FILMS, 2006, 498 (1-2) :146-151
[4]   Cardiac point of care testing: A focused review of current National Academy of Clinical Biochemistry guidelines and measurement platforms [J].
Christenson, Robert H. ;
Azzazy, Hassan M. E. .
CLINICAL BIOCHEMISTRY, 2009, 42 (03) :150-157
[5]   Label-free aptasensor for platelet-derived growth factor (PDGF) protein [J].
Degefa, Tesfaye Hailu ;
Kwak, Juhyoun .
ANALYTICA CHIMICA ACTA, 2008, 613 (02) :163-168
[6]   A study of love-wave acoustic sensors [J].
Du, J ;
Harding, GL ;
Ogilvy, JA ;
Dencher, PR ;
Lake, M .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 56 (03) :211-219
[7]   Cardiac markers: a clear cause for point-of-care testing [J].
Friess, Ulrich ;
Stark, Maik .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (05) :1453-1462
[8]   Recent developments on ZnO films for acoustic wave based bio-sensing and microfluidic applications: a review [J].
Fu, Y. Q. ;
Luo, J. K. ;
Du, X. Y. ;
Flewitt, A. J. ;
Li, Y. ;
Markx, G. H. ;
Walton, A. J. ;
Milne, W. I. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02) :606-619
[9]   A LOVE PLATE BIOSENSOR UTILIZING A POLYMER LAYER [J].
GIZELI, E ;
GODDARD, NJ ;
LOWE, CR ;
STEVENSON, AC .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :131-137
[10]   A NOVEL LOVE-PLATE ACOUSTIC SENSOR UTILIZING POLYMER OVERLAYERS [J].
GIZELI, E ;
STEVENSON, AC ;
GODDARD, NJ ;
LOWE, CR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (05) :657-659