Shake-Table Tests of a Full-Scale Three-Story Reinforced Masonry Shear Wall Structure

被引:20
|
作者
Stavridis, A. [1 ]
Ahmadi, F. [2 ,3 ]
Mavros, M. [4 ,5 ]
Shing, P. B. [5 ]
Klingner, R. E. [3 ]
McLean, D. [6 ]
机构
[1] SUNY Buffalo, Dept Civil Struct & Environm Engn, Buffalo, NY 14260 USA
[2] Walter P Moore & Associates, Res & Dev, Austin, TX 78701 USA
[3] Univ Texas Austin, Dept Civil Engn, Austin, TX 78712 USA
[4] Simpson Gumpertz & Heger Inc, Struct, 41 Seyon St Bldg 1,Suite 500, Waltham, MA 02453 USA
[5] Univ Calif San Diego, Dept Struct Engn, La Jolla, CA 92093 USA
[6] Colorado State Univ, Engn, Dept Civil & Environm Engn, Ft Collins, CO 80523 USA
关键词
Reinforced masonry; Shake-table test; Large-scale specimen; Shear walls; T-walls; Concrete and masonry structures; FLEXIBLE DIAPHRAGMS; SEISMIC EVALUATION; BUILDINGS;
D O I
10.1061/(ASCE)ST.1943-541X.0001527
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the shake-table tests of a full-scale, 3-story, reinforced concrete masonry structure. The structure was a special reinforced masonry shear wall system designed according to current code provisions for an area of high seismicity. It consisted of three lines of walls arranged in an H-shape in plan view, with one lineal and two T-walls aligned in the direction of the table motion and four lineal walls oriented perpendicular to the table motion. The seven walls were separated by door openings and were connected with lintels and precast slabs with cast-in-place concrete topping. The structure was subjected to a series of dynamic tests including nine seismic excitations with intensities exceeding the maximum considered earthquake used in the design. The structure had a capacity that exceeded considerably the design base shear, and it withstood all but the last two excitations with little or no damage. The paper presents the design of the test structure, its dynamic response to the seismic excitations, the evolution of damage, and the major observations and findings from the tests, including the influence of the concrete slabs, lintels, location of lap splices, and walls oriented perpendicular to the direction of the table motion on the structural performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Shake-Table Test of a Full-Scale 4-Story Precast Concrete Building. I: Overview and Experimental Results
    Gavridou, Sofia
    Wallace, John W.
    Nagae, Takuya
    Matsumori, Taizo
    Tahara, Kenich
    Fukuyama, Kunio
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (06)
  • [32] Shake-Table Tests of a 3-Story Masonry-Infilled RC Frame Retrofitted with Composite Materials
    Koutromanos, Ioannis
    Kyriakides, Marios
    Stavridis, Andreas
    Billington, Sarah
    Shing, P. Benson
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (08) : 1340 - 1351
  • [33] Damage Detection and Localization in a Full-Scale Slice of a Seven-Story Shear Wall Building Tested on the UCSD-NEES Shake Table
    Rahmani, Mohammadtaghi
    Todorovska, Maria I. I.
    Grabinski, Jaime R. R.
    Ebrahimian, Mahdi
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (01)
  • [34] Shake table tests on a tuff masonry structure strengthened with composite reinforced mortar
    De Santis, Stefano
    de Felice, Gianmarco
    COMPOSITE STRUCTURES, 2021, 275
  • [35] Evaluation of Seismic Demand on Nonstructural Elements Based on Shake-Table Testing of Full-Scale 2-Story Steel Moment Frame
    Jun, Su-Chan
    Lee, Cheol-Ho
    Bae, Chang-Jun
    Cho, Bong-Ho
    JOURNAL OF EARTHQUAKE ENGINEERING, 2024, 28 (14) : 4146 - 4162
  • [36] Effect of modeling assumptions on predicting seismic responses of a three-story reinforced concrete shear wall structure
    Xiao, Junyan
    Kwon, Oh-Sung
    Bentz, Evan
    Jung, Jae-Wook
    Kim, Minkyu
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, 53 (01): : 414 - 431
  • [37] Full-Scale Blast Tests on a Conventionally Designed Three-Story Steel Braced Frame with Composite Floor Slabs
    Hadjioannou, Michalis
    McKay, Aldo E.
    Benshoof, Phillip C.
    VIBRATION, 2021, 4 (04): : 865 - 892
  • [38] Full‐scale shake‐table tests on two unreinforced masonry cavity‐wall buildings: effect of an innovative timber retrofit
    Marco Miglietta
    Nicolò Damiani
    Gabriele Guerrini
    Francesco Graziotti
    Bulletin of Earthquake Engineering, 2021, 19 : 2561 - 2596
  • [39] Full-scale tests on masonry vaults strengthened with Steel Reinforced Grout
    De Santis, Stefano
    Roscini, Francesca
    de Felice, Gianmarco
    COMPOSITES PART B-ENGINEERING, 2018, 141 : 20 - 36
  • [40] Shake table tests on a full-scale six-storey cold-formed thin-walled steel-steel plate shear wall structure
    Zhou, Xuhong
    Yao, Xinmei
    Xu, Lei
    Shi, Yu
    Ke, Ke
    Liu, Liping
    THIN-WALLED STRUCTURES, 2022, 181