Calibration and Evaluation of a Frequency Domain Reflectometry Sensor for Real-Time Soil Moisture Monitoring

被引:78
|
作者
Ojo, E. RoTimi [1 ]
Bullock, Paul R. [1 ]
L'Heureux, Jessika [2 ]
Powers, Jarrett [3 ]
McNairn, Heather [4 ]
Pacheco, Anna [4 ]
机构
[1] Univ Manitoba, Dept Soil Sci, Winnipeg, MB R3T 2N2, Canada
[2] Agr & Agri Food Canada, Sci & Technol Branch, Calgary, AB T2P 0T8, Canada
[3] Agr & Agri Food Canada, Sci & Technol Branch, Winnipeg, MB R3C 3G7, Canada
[4] Agr & Agri Food Canada, Sci & Technol Branch, Ottawa, ON K1A 0C6, Canada
来源
VADOSE ZONE JOURNAL | 2015年 / 14卷 / 03期
关键词
WATER-CONTENT; FREEZE-THAW; CLAY LOAM; PROBE; FIELD;
D O I
10.2136/vzj2014.08.0114
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Soil spatial heterogeneity poses a challenge to accurate soil moisture determination. Remote sensing, in particular, using sensors that acquire data at microwave frequencies, is being used to overcome this challenge. In situ soil moisture monitoring can be used to validate remotely sensed surface soil moisture estimates and as inputs for agronomic and hydrologic models. Nine in situ soil moisture stations were established in Manitoba (Canada) and instrumented with Stevens Hydra Probes. The sensors were installed in triplicate with vertical orientation at the surface and with horizontal orientation at the 5-, 20-, 50-, and 100-cm depths. To ensure accuracy of the measured soil moisture, both laboratory and field calibrations were conducted. These calibrated soil moisture values were compared with the probe default values and those generated using published calibrations. Overall, the results showed that the field calibration was superior (coefficient of determination r(2) of 0.95) to the laboratory calibration (r(2) of 0.89). In addition, coarse-textured sites generally performed better than the fine-textured, high cation exchange capacity (CEC) sites. At the Kelburn site with high clay and CEC, the use of field calibration reduced the root mean square error from 0.188 to 0.026 m(3) m(-3). However, at the low clay and CEC Treherne site, gains in accuracy were minimal, about 0.005 m(3) m(-3). The laboratory calibration consistently underestimated soil moisture at all the evaluation sites, whereas both Topp and Logsdon calibrations overestimated soil moisture.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Time Domain Reflectometry flat sensor for non-invasive monitoring of moisture changes in building materials
    Suchorab, Zbigniew
    Majerek, Dariusz
    Koci, Vaclav
    Cerny, Robert
    MEASUREMENT, 2020, 165
  • [32] Next Generation System for Real-Time Monitoring of Rainfall, Soil Moisture, and Soil Temperature
    Rezaei, Hamid Fahim
    Sitter, Nicholas
    Kruger, Anton
    2011 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2011, : 70 - 75
  • [33] Evaluation of the WET sensor compared to time domain reflectometry
    Hamed, Yasser
    Samy, Ghada
    Persson, Magnus
    HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 2006, 51 (04): : 671 - 681
  • [34] Soil moisture in Pernambuco semiarid using time domain reflectometry (TDR)
    dos Santos, Thais E. M.
    Montenegro, Abelardo A. A.
    Silva, Demetrius D.
    REVISTA BRASILEIRA DE ENGENHARIA AGRICOLA E AMBIENTAL, 2011, 15 (07): : 670 - 679
  • [35] A METHOD OF MEASURING SOIL-MOISTURE BY TIME-DOMAIN REFLECTOMETRY
    LEDIEU, J
    DERIDDER, P
    DECLERCK, P
    DAUTREBANDE, S
    JOURNAL OF HYDROLOGY, 1986, 88 (3-4) : 319 - 328
  • [36] SOIL-MOISTURE DETERMINATION IN GRAVELLY SOILS WITH TIME DOMAIN REFLECTOMETRY
    DRUNGIL, CEC
    ABT, K
    GISH, TJ
    TRANSACTIONS OF THE ASAE, 1989, 32 (01): : 177 - 180
  • [37] Determining Moisture Content of Soil Layers with Time Domain Reflectometry and Micromechanics
    Lee, Sang Ick
    Zollinger, Dan G.
    Lytton, Robert L.
    TRANSPORTATION RESEARCH RECORD, 2008, (2053) : 30 - 38
  • [38] Advanced measurement methods in time domain reflectometry for soil moisture determination
    Huebner, C
    Schlaeger, S
    Becker, R
    Scheuermann, A
    Brandelik, A
    Schaedel, W
    Schuhmann, R
    ELECTROMAGNETIC AQUAMETRY: ELECTROMAGNETIC WAVE INTERACTION WITH WATER AND MOIST SUBSTANCES, 2005, : 317 - 347
  • [39] Using time-domain reflectometry for real-time monitoring of subsidence over an inactive mine in Virginia
    O'Connor, KM
    Crawford, J
    Price, K
    Sharpe, R
    GEOLOGY AND PROPERTIES OF EARTH MATERIALS 2004, 2004, (1874): : 147 - 154
  • [40] An Improved Calibration Determining Soil Bulk Density with Time Domain Reflectometry
    Ju, Zhaoqiang
    Liu, Xiaona
    Liu, Xiaojing
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2013, 44 (06) : 1072 - 1079