Gas-liquid simulation of an airlift bubble column reactor

被引:49
作者
Blazej, M
Glover, GMC
Generalis, SC
Markos, J
机构
[1] Slovak Univ Technol Bratislava, Dept Chem & Biochem Engn, Fac Chem & Food Technol, Bratislava 81237, Slovakia
[2] Aston Univ, Div Chem Engn & Appl Chem, Sch Engn & Appl Sci, Birmingham B4 7ET, W Midlands, England
关键词
airlift reactor (ALR); circulation velocity; gas holdup; CFD; computational fluid dynamics; modelling of hydrodynamics; fluent;
D O I
10.1016/S0255-2701(03)00010-2
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The simulation of two-phase flow for an experimental airlift reactor (32-1 volume) using commercially available software from Fluent Incorporated is presented here (http://www.fluent.co.uk). Data from the simulation is compared with the experimental data obtained by the tracking of a magnetic particle and analysis of the pressure drop to determine the gas hold-up. Comparisons between vertical velocity and gas hold-up were made for a series of experiments where the superficial gas velocity in the riser was adjusted between 0.01 and 0.075 m s(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 14 条
[1]  
[Anonymous], 1996, MIXTURE MODEL MULTIP
[2]  
[Anonymous], 1998, FLUENT US GUID
[3]  
Chisti MY, 1989, AIRLIFT BIOREACTORS
[4]  
Glover GMC, 2000, CHEM PAP, V54, P361
[5]  
GLOVER GMC, 2000, PRAG CZECH REP 27 31
[6]  
Kastanek F., 1993, CHEM REACTORS GAS LI
[7]  
Klein J, 2000, CHEM PAP, V54, P456
[8]   GAS HOLDUP AND BUBBLE FREQUENCY IN A BUBBLE-COLUMN REACTOR CONTAINING VISCOUS SACCHAROSE SOLUTIONS [J].
KUNCOVA, G ;
ZAHRADNIK, J .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1995, 34 (01) :25-34
[9]   STABLE AND ACCURATE CONVECTIVE MODELING PROCEDURE BASED ON QUADRATIC UPSTREAM INTERPOLATION [J].
LEONARD, BP .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1979, 19 (01) :59-98
[10]  
PATANAKAR SV, 1980, NUMERICAL HEAT TRANS