Study of the adhesion of thin plasma fluorocarbon coatings resisting plastic deformation for stent applications

被引:34
作者
Lewis, F. [1 ,2 ,3 ]
Horny, P. [1 ,2 ]
Hale, P. [1 ,2 ]
Turgeon, S. [1 ,2 ]
Tatoulian, M. [3 ]
Mantovani, D. [1 ,2 ]
机构
[1] Univ Laval, Dept Mat Engn, Lab Biomat & Bioengn, Quebec City, PQ G1K 7P4, Canada
[2] Univ Laval, Univ Hosp, Res Ctr, Quebec City, PQ G1K 7P4, Canada
[3] UPMC, ENSCP, Lab Genie Procedes Plasmas & Traitement Surfaces, F-75005 Paris, France
关键词
D O I
10.1088/0022-3727/41/4/045310
中图分类号
O59 [应用物理学];
学科分类号
摘要
Metallic intravascular stents are medical devices (316L stainless steel) used to support the narrowed lumen of atherosclerotic stenosed arteries. Despite the success of bare metal stents, restenosis remains the main complication after 3-6 months of implantation. To reduce the restenosis rate of bare metal stents, stent coating is an interesting alternative. Firstly, it allows the modification of the surface properties, which is in contact with the biological environment. Secondly, the coating could eventually act as a carrier for drug immobilization and release. Moreover, the in vivo stent implantation requires in situ stent expansion. This mandatory step generates local plastic deformation of up to 25% and may cause coating failures such as cracking and delamination. Fluorocarbon films were selected in this study as a potential stent coating, mainly due to their chemical inertness, high hydrophobicity, protein retention capabilities and thromboresistance properties. The aim of this study was to investigate the adhesion properties of fluorocarbon films of three different thicknesses deposited by plasma polymerization in C(2)F(6)/H(2) on 316L stainless steel substrates. A previously developed small punch test was used to deform the coated samples. According to atomic force microscopy, field emission scanning electron microscopy and x-ray photoelectron spectroscopy characterizations, among the coatings with different thicknesses studied, only those with a thickness of 36 nm exhibited the required cohesion and interfacial adhesion to resist the stent expansion without cracking or delaminating. Otherwise, cracks were detected in the coatings having thicknesses equal or superior to 100 nm, indicating a lack of cohesion.
引用
收藏
页数:7
相关论文
共 40 条
[1]   The deformation response of ultra-thin polymer films on steel sheet in a tensile straining test: the role of slip bands emerging at the polymer/metal interface [J].
Baumert, B ;
Stratmann, M ;
Rohwerder, M .
ZEITSCHRIFT FUR METALLKUNDE, 2004, 95 (06) :447-455
[2]  
BAUMERT B, 2003, MATER RES SOC S P, P795
[3]   Drug-eluting stents: A multidisciplinary success story [J].
Burt, HM ;
Hunter, WL .
ADVANCED DRUG DELIVERY REVIEWS, 2006, 58 (03) :350-357
[4]   Finite element simulation of stent and balloon interaction [J].
Chua, SND ;
Mac Donald, BJ ;
Hashmi, MSJ .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2003, 143 :591-597
[5]   Morphological and structural study of plasma deposited fluorocarbon films at different thicknesses [J].
Cicala, G ;
Milella, A ;
Palumbo, E ;
Favia, P ;
d'Agostino, R .
DIAMOND AND RELATED MATERIALS, 2003, 12 (10-11) :2020-2025
[6]   Nanostructure and composition control of fluorocarbon films from modulated tetrafluoroethylene plasmas [J].
Cicala, G ;
Milella, A ;
Palumbo, F ;
Rossini, P ;
Favia, P ;
d'Agostino, R .
MACROMOLECULES, 2002, 35 (24) :8920-8922
[7]   Repeated drug-eluting stent implantation for drug-eluting stent restenosis: The same or a different stent [J].
Cosgrave, John ;
Melzi, Gloria ;
Corbett, Simon ;
Biondi-Zoccai, Giuseppe G. L. ;
Babic, Rade ;
Airoldi, Flavio ;
Chieffo, Alaide ;
Sangiorgi, Giuseppe M. ;
Montorfano, Matteo ;
Michev, Iassen ;
Carlino, Mauro ;
Colombo, Antonio .
AMERICAN HEART JOURNAL, 2007, 153 (03) :354-359
[8]  
DAGOSTINO R, 2000, Patent No. 14297
[9]   Mechanical behaviour modelling of balloon-expandable stents [J].
Dumoulin, C ;
Cochelin, B .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1461-1470
[10]   Mechanical properties of coronary stents determined by using finite element analysis [J].
Etave, F ;
Finet, G ;
Boivin, M ;
Boyer, JC ;
Rioufol, G ;
Thollet, G .
JOURNAL OF BIOMECHANICS, 2001, 34 (08) :1065-1075