Automated constant denaturant capillary electrophoresis applied for detection of KRAS exon 1 mutations

被引:0
作者
Bjorheim, J [1 ]
Ekstrom, PO [1 ]
Fossberg, E [1 ]
Borresen-Dale, AL [1 ]
Gaudernack, G [1 ]
机构
[1] Norwegian Radium Hosp, Inst Canc Res, Dept Immunol, Sect Immunotherapy, N-0310 Oslo, Norway
关键词
D O I
10.2144/01305st01
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, we have applied automated constant denaturant capillary electrophoresis (ACDCE) for the detection of KRAS exon 1 mutations. Samples from 191 sporadic colon carcinomas previously analyzed for KRAS mutations with allele-specific PCR (ASPCR), temporal temperature gradient electrophoresis (TTGE), and constant denaturant capillary electrophoresis (CDCE) were analyzed. In ACDCE, an unmodified ABI PRISM(TM) 310 genetic analyzer with constant denaturant conditions separated fluorescein-labeled PCR products. Temperature in combination with a chemical denaturant was used for separation. The optimal separation conditions for PCR-amplified KRAS exon 1 fragments were determined by adjusting the temperature before electrophoresis. In the ACDCE analysis, the sequence of a mutant was determined by comparing the electropherogram of the fragment to that of known mutations followed by mixing the sample with control mutations before reanalysis. In a titration experiment mixing mutant and wild-type alleles, the sensitivity for mutation detection was shown to be 0.6% in this automated CDCE technique. The automation of CDCE allowed rapid analysis of a large number of test samples over as short period of time and with a commercially available apparatus.
引用
收藏
页码:972 / 975
页数:4
相关论文
共 50 条
  • [41] Portable Capillary Electrophoresis Instrument with Automated Injector and Contactless Conductivity Detection
    Thanh Duc Mai
    Thi Thanh Thuy Pham
    Hung Viet Pham
    Saiz, Jorge
    Garcia Ruiz, Carmen
    Hauser, Peter C.
    ANALYTICAL CHEMISTRY, 2013, 85 (04) : 2333 - 2339
  • [42] Automated detection and removal of capillary electrophoresis artifacts due to spectral overlap
    Adelman, Jonathan D.
    Zhao, Angie
    Eberst, D. Spencer
    Marciano, Michael A.
    ELECTROPHORESIS, 2019, 40 (14) : 1753 - 1761
  • [43] DETECTION OF POINT MUTATIONS IN DNA USING CAPILLARY ELECTROPHORESIS IN A POLYMER NETWORK
    KUYPERS, AWHM
    WILLEMS, PMW
    VANDERSCHANS, MJ
    LINSSEN, PCM
    WESSELS, HMC
    DEBRUIJN, CHMM
    EVERAERTS, FM
    MENSINK, EJBM
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 621 (02): : 149 - 156
  • [44] Temperature-programmed capillary electrophoresis for detection of DNA point mutations
    Gelfi, C
    Cremonesi, L
    Ferrari, M
    Righetti, PG
    BIOTECHNIQUES, 1996, 21 (05) : 926 - &
  • [45] Non-isocratic capillary electrophoresis for detection of DNA point mutations
    Righetti, PG
    Gelfi, C
    JOURNAL OF CHROMATOGRAPHY B, 1997, 697 (1-2): : 195 - 205
  • [46] SensiScreen® KRAS exon 2-sensitive simplex and multiplex real-time PCR-based assays for detection of KRAS exon 2 mutations
    Riva, Alice
    Borgesen, Michael
    Guldmann-Christensen, Mariann
    Kyneb, Majbritt Hauge
    Voogd, Kirsten
    Andersen, Christina
    Epistolio, Samantha
    Merlo, Elisabetta
    Wolff, Tine Yding
    Hamilton-Dutoit, Stephen
    Lorenzen, Jan
    Christensen, Ulf Bech
    Frattini, Milo
    PLOS ONE, 2017, 12 (06):
  • [47] Sensitivity and Specificity of Automated PCR (Idylla) in the Detection of KRAS Mutations in Colorectal Carcinoma
    Colling, R.
    Wang, L. M.
    Soilleux, E.
    JOURNAL OF PATHOLOGY, 2016, 240 : 31 - 31
  • [48] A Simple Method for Improving the Limit of Detection for Capillary Electrophoresis DNA Sequencing - A Comparison of Methodologies for KRAS Variant Detection
    Davidson, C.
    Zeringer, E.
    Champion, K.
    Gauthier, M.
    Wang, F.
    Boonyaratanakornkit, J.
    Jones, J. R.
    Schreiber, E.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (06) : 740 - 741
  • [49] AUTOMATED VELOCITY PROGRAMMING FOR INCREASED DETECTION ZONE RESIDENCE TIMES IN CAPILLARY ELECTROPHORESIS
    SHEAR, JB
    COLON, LA
    ZARE, RN
    ANALYTICAL CHEMISTRY, 1993, 65 (24) : 3708 - 3712
  • [50] Automated Capillary Electrophoresis Immunoblot for the Detection of Alpha-Synuclein in Mouse Tissue
    Erdmann, Leonie
    Santos, Icia I.
    Rieper, Petra
    Klafki, Hans W.
    Beutner, Dirk
    Wiltfang, Jens
    Outeiro, Tiago F.
    Setz, Cristian
    JOURNAL OF PARKINSONS DISEASE, 2024, 14 (04) : 681 - 692