Comparison of Woven EndoBridge device sizing with conventional measurements and virtual simulation using the Sim&Size software: a multicenter experience

被引:15
作者
Cagnazzo, Federico [1 ]
Marnat, Gaultier [2 ]
Ferreira, Ivan [1 ]
Daube, Pierre [3 ]
Derraz, Imad [1 ]
Dargazanli, Cyril [1 ]
Lefevre, Pierre-Henri [1 ]
Gascou, Gregory [1 ]
Riquelme, Carlos [1 ]
Morganti, Riccardo [4 ]
Berge, Jerome [2 ]
Gariel, Florent [2 ]
Barreau, Xavier [2 ]
Costalat, Vincent [1 ]
机构
[1] Ctr Hosp Reg Univ CHRU Montpellier, Neuroradiol Dept, Montpellier, France
[2] Ctr Hosp Univ CHU Bordeaux, Intervent & Diagnost Neuroradiol, Bordeaux, France
[3] Ctr Hosp Univ CHU Poitiers, Intervent Radiol, Poitiers, France
[4] Univ Hosp Pisa, Sect Stat, Pisa, Italy
关键词
aneurysm; angiography; intervention; subarachnoid; WEB ANEURYSM TREATMENT; TREATMENT OCCLUSION STABILITY; ENDOVASCULAR TREATMENT; COMPLEX;
D O I
10.1136/neurintsurg-2020-017060
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Selection of the appropriate device size mandatory during aneurysm treatment with a Woven EndoBridge (WEB). We aimed to investigate if virtual simulation with Sim&Size software may have an impact on technical, angiographic, and clinical outcomes after WEB treatment. Methods Data from two large-volume centers were collected and compared (January 2017-January 2020). Virtual simulation was systematically adopted in one center, while conventional sizing was used in the other one. Outcomes were the duration of intervention, the radiation dose (in milligrays, the number of corrective interventions for inappropriate WEB size, the number of WEBs not deployed, angiographic occlusion, and complications. Univariate and multivariate linear models were adopted. Results A total of 186 aneurysms were treated with WEB (109 with and 77 without virtual simulation). Patient characteristics and aneurysm features were comparable among virtual and conventional sizing, except for mean age (62.2 +/- 11.8 years and 56.2 +/- 10.1 years, P=0.0004) and median aspect ratio (1.6, IQR=1.2-2 and 1.2, IQR=1-1.6, P=0.0001). Years of operator experience were comparable. Virtual simulation was independently associated with shorter intervention time (45 min, IQR=33-63.5 min vs 63.5 min, IQR=41-84.7 min, P=0.0001), lower radiation dose (1051 mGy, IQR=815-1399 mGy vs 1207 mGy, IQR=898-2084 mGy, P=0.0001), and lower number of WEBs not deployed (26/77=33.7% vs 8/109=7.3%, P=0.0001). The need for additional maneuvers was significantly lower in the virtual simulation group (5/109=4.6% vs 12/77=15.6%, P=0.021). Angiographic outcomes and complications were comparable. Conclusions In this multicenter experience, virtual simulation with Sim&Size software seems to facilitate the selection of the appropriate WEB device for aneurysm treatment, reducing the time of intervention, the radiation dose, the number of devices not deployed, and the need for corrective interventions.
引用
收藏
页码:924 / 929
页数:7
相关论文
共 15 条
[1]   The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study [J].
Arthur, Adam S. ;
Molyneux, Andy ;
Coon, Alexander L. ;
Saatci, Isil ;
Szikora, Istvan ;
Baltacioglu, Feyyaz ;
Sultan, Ali ;
Hoit, Daniel ;
Almandoz, Josser E. Delgado ;
Elijovich, Lucas ;
Cekirge, Saru ;
Byrne, James, V ;
Fiorella, David ;
Arthur, Adam ;
Woo, Henry ;
Coon, Alexander ;
Colby, Geoffrey ;
Cekirge, Saruhan ;
Asadov, Ruslan ;
Chavali, Ram ;
Frerich, Kai ;
Delgado, Josser ;
Kayan, Yasha ;
Hanel, Ricardo ;
Sauvageau, Eric ;
Turner, Raymond ;
Chaudry, Imran ;
Spiotta, Alejandro ;
Turk, Aquila ;
Rai, Ansaar ;
Carpenter, Jeffrey ;
Boo, Sohyun ;
Jabbour, Pascal ;
Tjoumakaris, Stavropoula ;
Rosenwasser, Robert ;
Woodward, Keith ;
Boulos, Alan ;
Dalfino, John ;
Yamamoto, Junichi ;
Vora, Nirav ;
Budzik, Ronald ;
Pema, Peter ;
Davis, Thomas ;
Kallmes, David ;
Lanzino, Giuseppe ;
Cloft, Harry ;
Siddiqui, Adnan ;
Levy, Elad ;
Snyder, Kenneth ;
Lopes, Demetrius .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (09) :924-930
[2]   Treatment of Wide-Neck Intracranial Aneurysms with the Woven EndoBridge Device Associated with Stenting: A Single-Center Experience [J].
Cagnazzo, F. ;
Ahmed, R. ;
Dargazanli, C. ;
Lefevre, P-H ;
Gascou, G. ;
Derraz, I ;
Kalmanovich, S. A. ;
Riquelme, C. ;
Bonafe, A. ;
Costalat, V .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) :820-826
[3]   Single-Layer WEBs: lntrasaccular Flow Disrupters for Aneurysm Treatment-Feasibility Results from a European Study [J].
Caroff, J. ;
Mihalea, C. ;
Klisch, J. ;
Strasilla, C. ;
Berlis, A. ;
Patankar, T. ;
Weber, W. ;
Behme, D. ;
Jacobsen, E. A. ;
Liebig, T. ;
Prothmann, S. ;
Cognard, C. ;
Finkenzeller, T. ;
Moret, J. ;
Spelle, L. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (10) :1942-1946
[4]   In Reply: WEB Aneurysm Treatment: Occlusion Stability and "Compression" [J].
Cognard, Christophe ;
Januel, Anne Christine .
NEUROSURGERY, 2015, 77 (04) :E667-E669
[5]   Silent embolism after stent-assisted coiling of cerebral aneurysms: diffusion-weighted MRI study of 75 cases [J].
Hahnemann, M. L. ;
Ringelstein, A. ;
Sandalcioglu, I. E. ;
Goericke, S. ;
Moenninghoff, C. ;
Wanke, I. ;
Forsting, M. ;
Sure, U. ;
Schlamann, M. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (06) :461-465
[6]   Software-based simulation for preprocedural assessment of braided stent sizing: a validation study [J].
Joshi, Krishna Chaitanya ;
Larrabide, Ignacio ;
Saied, Ahmed ;
Elsaid, Nada ;
Fernandez, Hector ;
Lopes, Demetrius K. .
JOURNAL OF NEUROSURGERY, 2019, 131 (05) :1423-1429
[7]   WEB as part of a multimodality treatment in complex, large, and partially thrombosed intracranial aneurysms: a single-center observational study of technical success, safety, and recurrence [J].
Kabbasch, C. ;
Mpotsaris, A. ;
Reiner, M. ;
Liebig, T. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (12) :1235-+
[8]   Woven Endobridge (WEB) device for endovascular treatment of complex unruptured aneurysms-a single center experience [J].
Lescher, Stephanie ;
de Rochemont, Richard du Mesnil ;
Berkefeld, Joachim .
NEURORADIOLOGY, 2016, 58 (04) :383-390
[9]   Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study [J].
Ospel, J. M. ;
Gascou, G. ;
Costalat, V. ;
Piergallini, L. ;
Blackham, K. A. ;
Zumofen, D. W. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (03) :524-530
[10]   Virtual simulation with Sim&Size software for Pipeline Flex Embolization: evaluation of the technical and clinical impact [J].
Piergallini, Lorenzo ;
Cagnazzo, Federico ;
Conte, Giorgio ;
Dargazanli, Cyril ;
Derraz, Imad ;
Lefevre, Pierre-Henri ;
Gascou, Gregory ;
Mantilla, Daniel ;
Riquelme, Carlos ;
Bonafe, Alain ;
Costalat, Vincent .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (10) :968-973