A pilot study to precisely quantify forces applied by sonographers while scanning: A step toward reducing ergonomic injury

被引:51
作者
Dhyani, Manish [1 ]
Roll, Shawn C. [2 ]
Gilbertson, Matthew W. [3 ]
Orlowski, Melanie [1 ]
Anvari, Arash [1 ]
Li, Qian [1 ]
Anthony, Brian [3 ]
Samir, Anthony E. [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Univ Southern Calif, Chan Div Occupat Sci & Occupat Therapy, Los Angeles, CA USA
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
来源
WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION | 2017年 / 58卷 / 02期
关键词
Ergonomics; ultrasound; sonographers; injury; force measurement; work-related injury; DIAGNOSTIC MEDICAL SONOGRAPHERS; VASCULAR TECHNOLOGISTS; WORK; DISCOMFORT; PREVALENCE; SIZE;
D O I
10.3233/WOR-172611
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
BACKGROUND: There is a significantly high rate of work-related musculsokeletal injuries in sonography professionals. To date, assessment of risk factors for work-related injuries in sonographers has been based primarily on surveys, subjective reports, and observational methods. There is a need to develop quantitative techniques to better understand risk factors and develop preventive interventions. OBJECTIVE: We pilot tested a high-resolution force-measuring probe capable of precisely measuring forces applied through the transducer by sonographers and used this novel direct measurement technique to evaluate forces during abdominal imaging. METHODS: Twelve sonographers with varied experience, ranging from 1-33 years, performed routine abdominal scans on 10 healthy volunteers who had varied body mass indices (BMI). Imaging was conducted using the force-measuring probe, which provided real-time measurement of forces, and angles. Data were compared by sonographer years of experience and subject BMI. RESULTS: In total, 47 abdominal examinations were performed as part of this study, and all images met standards for clinical diagnostic quality. The mean contact force applied across all exams was 8.2 +/- 4.3 Newtons (N) (range: 1.2-36.5 N). For subjects in the high BMI group (BMI> 25, n = 4) the mean force was 10.5N (range: 8.9-13.2 N) compared to 7.9N (range: 5.9-10.9 N) for subjects with normal BMI (BMI = 18.5-25, n = 6). Similarly, the mean maximum force applied for subjects with high BMI (25.3 N) was significantly higher than force applied for subjects with normal BMI (17.4 N). No significant difference was noted in the amount of force applied by sonographers with more than 5 years of experience (n = 6) at 8.2N (Range: 5.1-10.0 N) compared to less experienced sonographers (n = 6), whose forces averaged 8.1N (Range: 5.8-10.0 N). CONCLUSIONS: It is feasible to directly measure forces applied by sonographers using a high-resolution force measurement system. Forces applied during abdominal imaging vary widely, are significantly higher when scanning subjects with high BMI, and are not related to sonographer years of experience. This force measurement system has the potential to provide an additional quantitative data point to explore the impact of applied forces on sonographer related musculoskeletal injury, particularly in conjunction with various body positions, exam types and force durations.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 21 条
[11]  
Habes D J, 2000, Appl Occup Environ Hyg, V15, P521
[12]   Anthropometric measurements, job strain, and prevalence of musculoskeletal symptoms in female medical sonographersf [J].
Hill, James J., III ;
Slade, Martin D. ;
Russi, Mark B. .
WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2009, 33 (02) :181-189
[13]   Work-related musculoskeletal complaints in sonologists [J].
Magnavita, N ;
Bevilacqua, L ;
Mirk, P ;
Fileni, A ;
Castellino, N .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1999, 41 (11) :981-988
[14]  
Muir M., 2004, J Diagn Med Sonogr, V20, P317, DOI [10.1177/8756479304266737, DOI 10.1177/8756479304266737]
[15]   Surface EMG Evaluation of Sonographer Scanning Postures [J].
Murphey, Susan L. ;
Milkowski, Andy .
JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2006, 22 (05) :298-305
[16]   Prevalence of Childhood and Adult Obesity in the United States, 2011-2012 [J].
Ogden, Cynthia L. ;
Carroll, Margaret D. ;
Kit, Brian K. ;
Flegal, Katherine M. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (08) :806-814
[17]   Upper Extremity Kinematics in Sonographers During Kidney Scanning [J].
Pocratsky, Jennifer ;
Ashby, Blake ;
Beasley, Jeanine .
JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2014, 30 (02) :67-76
[18]   Contribution of positioning to work-related musculoskeletal discomfort in diagnostic medical sonographers [J].
Roll, Shawn C. ;
Selhorst, Lauren ;
Evans, Kevin D. .
WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2014, 47 (02) :253-260
[19]   An analysis of occupational factors related to shoulder discomfort in diagnostic medical sonographers and vascular technologists [J].
Roll, Shawn C. ;
Evans, Kevin D. ;
Hutmire, Cristina D. ;
Baker, Joan P. .
WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2012, 42 (03) :355-365
[20]   Variation of Pinch and Grip Force Between Different Size Transducers: A Preliminary Study [J].
Vetter, Lauren ;
Beasley, Jeanine ;
Ashby, Blake ;
Bullock, Hannah ;
Conroy, Chad ;
Pocratsky, Jennifer .
JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2013, 29 (06) :245-252