Submerged anaerobic membrane bioreactor applied for mainstream municipal wastewater treatment at a low temperature: Sludge yield, energy balance and membrane filtration behaviors

被引:21
作者
Ji, Jiayuan [1 ,2 ]
Du, Runda [2 ]
Ni, Jialing [3 ]
Chen, Yujie [2 ]
Hu, Yisong [4 ]
Qin, Yu [2 ]
Hojo, Toshimasa [5 ]
Li, Yu -You [2 ,3 ]
机构
[1] Tohoku Univ, Inst Fluid Sci, Aoba Ku, 2-1-1 Katahira, Sendai 9808577, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Civil & Environm Engn, Aoba Ku, 6-6-06 Aoba, Aramaki, Sendai 9808579, Japan
[3] Tohoku Univ, Grad Sch Environm Studies, Dept Frontier Sci Adv Environm, Aoba Ku, 6-6-06 Aoba, Aramaki, Sendai 9808579, Japan
[4] Xian Univ Architecture & Technol, Key Lab Environm Engn, 13 Yanta Rd, Xian 710055, Shaanxi, Peoples R China
[5] Tohoku Inst Technol, Dept Civil Engn & Management, Taihaku Ku, 35-1,Yagiyamakasumi cho, Sendai 9828577, Japan
基金
日本学术振兴会;
关键词
Anaerobic membrane bioreactor; Low temperature; Real municipal wastewater; Bioenergy recovery; Energy balance; DEGREES-C; ANMBR; PERFORMANCE; METHANE; SEWAGE; HRT; STRENGTH; IMPACT; BIOGAS; MODEL;
D O I
10.1016/j.jclepro.2022.131831
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The anaerobic membrane bioreactor (AnMBR) has potential as a low-cost wastewater treatment process with the benefit of energy production. However, to ensure satisfactory treatment performance, an AnMBR is operated at a relatively high temperature currently. Research focused on the operation of the AnMBR at low temperature is significant since the energy required for heating is an impediment to the application of AnMBRs for municipal wastewater treatment. Hence, in this study, a constant low-temperature (15 C) AnMBR was evaluated for the treatment of real municipal wastewater with hydraulic retention times (HRTs) in the range of 6-24 h. During the long-term experiment, a chemical oxygen demand (COD) removal efficiency of approximately 90.5% was obtained with a sludge yield below 0.13 g-VSS/g-CODrem at HRTs of 16 and 24 h. The amount of energy generated was theoretically calculated based on biogas production, with a high of 0.62 kWh/t. The energy balance analysis showed that the AnMBR process can be energy positive under the optimal operational conditions investigated. Membrane filtration performed well during operation at 15 degrees C with HRTs ranging between 12 and 24 h, while it was compromised at the extremely short HRT of 6 h. In this study, the effectiveness of optimizing the conditions on the performance of the AnMBR operating at low temperature was confirmed, along with the potential for energy recoverability under those conditions.
引用
收藏
页数:9
相关论文
共 56 条
[1]   From a lab test to industrial application: scale-up of Fenton process for real olive mill wastewater treatment [J].
Amaral-Silva, Nuno ;
Martins, Rui C. ;
Nunes, Paulo ;
Castro-Silva, Sergio ;
Quinta-Ferreira, Rosa M. .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2017, 92 (06) :1336-1344
[2]  
APHA, 2007, Standard Methods for the Examination of Water and Wastewater, V22nd, DOI DOI 10.2105/AJPH.51.6.940-A
[3]   Limiting Flux and Critical Transmembrane Pressure Determination Using an Exponential Model: The Effect of Concentration Factor, Temperature, and Cross-Flow Velocity during Casein Micelle Concentration by Microfiltration [J].
Astudillo-Castro, Carolina L. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2015, 54 (01) :414-425
[4]   Assessment of Power Generation Using Biogas from Landfills in an Equatorial Tropical Context [J].
Barragan-Escandon, Antonio ;
Olmedo Ruiz, Jonathan Miguel ;
Curillo Tigre, Jonnathan David ;
Zalamea-Leon, Esteban F. .
SUSTAINABILITY, 2020, 12 (07)
[5]   Novel anaerobic membrane bioreactor (AnMBR) design for wastewater treatment at long HRT and high solid concentration [J].
Berkessa, Yifru Waktole ;
Yan, Binghua ;
Li, Tengfei ;
Tan, Ming ;
She, Zonglian ;
Jegatheesan, Veeriah ;
Jiang, Heqing ;
Zhang, Yang .
BIORESOURCE TECHNOLOGY, 2018, 250 :281-289
[6]  
Brandt M.J., 2017, CHEM MICROBIOLOGY BI, P235, DOI [10.1016/B978-0-08-100025-0.00007-7, DOI 10.1016/B978-0-08-100025-0.00007-7]
[7]   Evaluation of a sponge assisted-granular anaerobic membrane bioreactor (SG-AnMBR) for municipal wastewater treatment [J].
Chen, C. ;
Guo, W. S. ;
Ngo, H. H. ;
Liu, Y. ;
Du, B. ;
Wei, Q. ;
Wei, D. ;
Nguyen, D. D. ;
Chang, S. W. .
RENEWABLE ENERGY, 2017, 111 :620-627
[8]   Robustness of granular activated carbon-synergized anaerobic membrane bioreactor for pilot-scale application over a wide seasonal temperature change [J].
Chen, Cheng ;
Sun, Mingzhuang ;
Liu, Ziwei ;
Zhang, Jiao ;
Xiao, Kang ;
Zhang, Xian ;
Song, Guangqing ;
Chang, Jiang ;
Liu, Guoliang ;
Wang, Hao ;
Huang, Xia .
WATER RESEARCH, 2021, 189
[9]   Impact of reactor configurations on the performance of a granular anaerobic membrane bioreactor for municipal wastewater treatment [J].
Chen, Cheng ;
Guo, Wenshan ;
Ngo, Huu Hao ;
Chang, Soon Woong ;
Dinh Duc Nguyen ;
Phuoc Dan Nguyen ;
Xuan Thanh Bui ;
Wu, Yun .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2017, 121 :131-138
[10]   Investigating the mechanism of sludge reduction in activated sludge with an anaerobic side-stream reactor [J].
Chon, Dong-Hyun ;
Rome, McNamara ;
Kim, Hee-Sik ;
Park, Chul .
WATER SCIENCE AND TECHNOLOGY, 2011, 63 (01) :93-99