Corneal Endothelial Cell Loss and Morphometric Changes 5 Years after Phacoemulsification with or without CyPass Micro-Stent

被引:83
作者
Lass, Jonathan H. [1 ]
Benetz, Beth Ann [1 ]
He, Jonathan [2 ]
Hamilton, Cody [2 ]
Von Tress, Mark [2 ]
Dickerson, Jaime [2 ,3 ]
Lane, Stephen [2 ,4 ]
机构
[1] Case Western Reserve Univ, Univ Hosp Eye Inst, Dept Ophthalmol & Visual Sci, Cornea Image Anal Reading Ctr, Cleveland, OH 44106 USA
[2] Alcon Res LLC, Ft Worth, TX USA
[3] Univ North Texas Hlth Sci Ctr, North Texas Eye Res Inst, Ft Worth, TX USA
[4] Univ Minnesota, Dept Ophthalmol, Minneapolis, MN 55455 USA
关键词
MITOMYCIN-C; GLAUCOMA; DENSITY; MICROINCISION; VALVE;
D O I
10.1016/j.ajo.2019.07.016
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To characterize long-term changes in corneal endothelial cells after phacoemulsification with or without supraciliary Micro-Stent (Alcon) implantation in eyes with open-angle glaucoma (OAG) and visually significant cataract. DESIGN: Three-year safety extension of a 2-year randomized clinical trial. METHODS: Patients from the multicenter Study of an Implantable Device for Lowering Intraocular Pressure in Glaucoma Patients Undergoing Cataract Surgery (COMPASS) trial who underwent Micro-Stent implantation plus phacoemulsification (n = 282) or phacoemulsification alone (n = 67) were analyzed post hoc. Specular microscopy was used to assess endothelial cell loss (ECL), including changes from baseline in endothelial cell density (ECD), coefficient of variation, and percentage of hexagonal cells. RESULTS: Preoperative ECDs in the microstent group (2,432.6 cells/mm(2) [95% confidence interval [CI], 2,382.8-2,482.4 cells/mm(2)]) were similar to those in the control group (2,434.5 cells/mm(2) [95% CI, 2,356.5-2,512.4 cells/mm2]) groups. ECL at months 48 and 60 was greater in the Micro-Stent group than in the control group. At month 60, the mean percent of changes in ECD was- 20.4% (95% CI,- 23.5% to- 17.5%) in the Micro-Stent group and- 10.1% (95% CI,-13.9% to- 6.3%) in the control group. No statistically significant between-group changes from baseline in cellular morphology were observed. Nine adverse events were possibly related to ECL, including 3 eyes with transient focal corneal edema and 4 eyes that required Micro-Stent trimming due to protrusion. CONCLUSIONS: In eyes with OAG, ECL after phacoemulsification is acute and stabilizes after 3 months, whereas ECL after phacoemulsification plus MicroStent implantation proceeds for at least 5 years. Clinical findings associated with ECL in these eyes were uncommon (3.3% of implanted eyes), suggesting that ECL is generally a subclinical phenomenon. ((C) 2019 Published by Elsevier Inc.)
引用
收藏
页码:211 / 218
页数:8
相关论文
共 33 条
[1]  
Alcon, 2018, ALC ANN VOL GLOB MAR
[2]  
Alcon Laboratories Inc., 2016, CYPASS MICR INSTR US
[3]  
American National Standard Institute, 2019, AM NAT STAND OPHTH I
[4]  
[Anonymous], 2000, SEMIN OPHTHALMOL S1, V45, pS131
[5]  
Batlan S J, 1996, Curr Opin Ophthalmol, V7, P52, DOI 10.1097/00055735-199608000-00010
[6]   Clinical responses of the corneal endothelium [J].
Bourne, WM ;
McLaren, JW .
EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) :561-572
[7]   Changes in corneal endothelial cell density in patients with normal-tension glaucoma [J].
Cho, Sung Woo ;
Kim, Joon Mo ;
Choi, Chul Young ;
Park, Ki Ho .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (06) :569-573
[8]   The effect of combined phacotrabeculectomy, trabeculectomy and phacoemulsification on the corneal endothelium in the early stage: a preliminary study [J].
Demir, Atila Gokce ;
Olgun, Ali ;
Guven, Dilek ;
Demir, Mehmet ;
Sendul, Selam Yekta ;
Acar, Ozge Pinar Akarsu ;
Kacar, Hakan .
INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (09) :2121-2128
[9]  
Dick B., 1995, Ophthalmologe, V92, P476
[10]  
Dick HB, 1996, J CATARACT REFR SURG, V22, P63