Computed Tomography Imaging of Primary Lung Cancer in Mice Using a Liposomal-Iodinated Contrast Agent

被引:48
作者
Badea, Cristian T. [1 ]
Athreya, Khannan K. [2 ]
Espinosa, Gabriela [3 ,4 ]
Clark, Darin [1 ]
Ghafoori, A. Paiman [5 ]
Li, Yifan [5 ]
Kirsch, David G. [5 ,6 ]
Johnson, G. Allan [1 ]
Annapragada, Ananth [3 ]
Ghaghada, Ketan B. [3 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27706 USA
[2] Univ Texas Hlth Sci Ctr Houston, Univ Texas, Med Sch Houston, Houston, TX USA
[3] Texas Childrens Hosp, Edward B Singleton Dept Pediat Radiol, Houston, TX 77030 USA
[4] Univ Texas Hlth Sci Ctr Houston, Sch Biomed Informat, Houston, TX USA
[5] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC USA
[6] Duke Univ, Med Ctr, Dept Pharmacol & Canc Biol, Durham, NC USA
关键词
PULMONARY NODULES; CT; ALGORITHM;
D O I
10.1371/journal.pone.0034496
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To investigate the utility of a liposomal-iodinated nanoparticle contrast agent and computed tomography (CT) imaging for characterization of primary nodules in genetically engineered mouse models of non-small cell lung cancer. Methods: Primary lung cancers with mutations in K-ras alone (Kras(LA1)) or in combination with p53 (LSL-Kras(G12D);p53(FL/FL)) were generated. A liposomal-iodine contrast agent containing 120 mg Iodine/mL was administered systemically at a dose of 16 mu l/gm body weight. Longitudinal micro-CT imaging with cardio-respiratory gating was performed pre-contrast and at 0 hr, day 3, and day 7 post-contrast administration. CT-derived nodule sizes were used to assess tumor growth. Signal attenuation was measured in individual nodules to study dynamic enhancement of lung nodules. Results: A good correlation was seen between volume and diameter-based assessment of nodules (R-2>0.8) for both lung cancer models. The LSL-Kras(G12D);p53(FL/FL) model showed rapid growth as demonstrated by systemically higher volume changes compared to the lung nodules in Kras(LA1) mice (p<0.05). Early phase imaging using the nanoparticle contrast agent enabled visualization of nodule blood supply. Delayed-phase imaging demonstrated significant differential signal enhancement in the lung nodules of LSL-Kras(G12D);p53(FL/FL) mice compared to nodules in Kras(LA1) mice (p<0.05) indicating higher uptake and accumulation of the nanoparticle contrast agent in rapidly growing nodules. Conclusions: The nanoparticle iodinated contrast agent enabled visualization of blood supply to the nodules during the early-phase imaging. Delayed-phase imaging enabled characterization of slow growing and rapidly growing nodules based on signal enhancement. The use of this agent could facilitate early detection and diagnosis of pulmonary lesions as well as have implications on treatment response and monitoring.
引用
收藏
页数:7
相关论文
共 34 条
[1]  
[Anonymous], 2011, NEW ENGLAND J MED, V365, P395
[2]   Micro-CT with respiratory and cardiac gating [J].
Badea, C ;
Hedlund, LW ;
Johnson, GA .
MEDICAL PHYSICS, 2004, 31 (12) :3324-3329
[3]  
Badea C. T., 2011, MED IMAGING 2011 PHY, P7961
[4]  
Baden C, 2008, DUAL MICROCT SYSTEM
[5]  
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]   Nanodelivery of MRI Contrast Agent Enhances Sensitivity of Detection of Lung Cancer Metastases [J].
Freedman, Matthew ;
Chang, Esther H. ;
Zhou, Qi ;
Pirollo, Kathleen F. .
ACADEMIC RADIOLOGY, 2009, 16 (05) :627-637
[8]   Detection of primary lung tumors in rodents by magnetic resonance imaging [J].
Garbow, JR ;
Zhang, ZQ ;
You, M .
CANCER RESEARCH, 2004, 64 (08) :2740-2742
[9]   Evaluation of Tumor Microenvironment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging [J].
Ghaghada, Ketan B. ;
Badea, Cristian T. ;
Karumbaiah, Lohitash ;
Fettig, Nicole ;
Bellamkonda, Ravi V. ;
Johnson, G. A. ;
Annapragada, Ananth .
ACADEMIC RADIOLOGY, 2011, 18 (01) :20-30
[10]   Iodinated blood pool contrast media for preclinical X-ray imaging applications - A review [J].
Hallouard, Francois ;
Anton, Nicolas ;
Choquet, Philippe ;
Constantinesco, Andre ;
Vandamme, Thierry .
BIOMATERIALS, 2010, 31 (24) :6249-6268