In this paper, the combined cooling, heating and power (CCHP) systems used in a new university campus, which is located in Changchun (in the severe cold zone of northeast of china), is evaluated. According to the simulation results, this paper analyzes the energy consumption of a conventional system and the CCHP systems. Furthermore, the environmental issues are assessed using the proposed emission model. In addition, in order to evaluate some benefits for energy-saving, emission reduction and economical aspects, a sensitivity analysis is carried out by comparing the power generation capacity of CCHP and the price of electricity and gas. (C) 2016 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:361 / 372
页数:12
相关论文
共 50 条
  • [21] Influence analysis of building energy demands on the optimal design and performance of CCHP system by using statistical analysis
    Yang, G.
    Zheng, C. Y.
    Zhai, X. Q.
    ENERGY AND BUILDINGS, 2017, 153 : 297 - 316
  • [22] Analysis of performance and suitable users of CCHP systems with active thermal energy storage
    Mo, Junrong
    Dai, Xiaoye
    Xu, Shuhan
    Shi, Lin
    Feng, Lejun
    APPLIED THERMAL ENGINEERING, 2023, 229
  • [23] Performance analysis of CCHP and CHP systems operating following the thermal and electric load
    Mago, P. J.
    Fumo, N.
    Chamra, L. M.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (09) : 852 - 864
  • [24] Water-energy-carbon nexus at campus scale: Case of North China University of Water Resources and Electric Power
    Li, Ruishi
    Zhao, Rongqin
    Xie, Zhixiang
    Xiao, Liangang
    Chuai, Xiaowei
    Feng, Mengyu
    Zhang, Huifang
    Luo, Huili
    ENERGY POLICY, 2022, 166
  • [25] Optimization and performance analysis of CCHP-GSHP-SE system under different start factors
    Deng, Yan
    Liu, Yicai
    Zhang, Yu
    Zeng, Rong
    Zheng, Zimin
    Yao, Yao
    Wu, Likang
    Gong, Zan
    Liu, Shiyan
    ENERGY CONVERSION AND MANAGEMENT, 2022, 266
  • [26] Summer performance analysis of coal-based CCHP with new configurations comparing with separate system
    Wei, Maolin
    Yuan, Weixing
    Fu, Lin
    Zhang, Shigang
    Zhao, Xiling
    ENERGY, 2018, 143 : 104 - 113
  • [27] Performance analysis and optimization of a CCHP-GSHP coupling system based on quantum genetic algorithm
    Li, Bolun
    Hu, Pingfang
    Zhu, Na
    Lei, Fei
    Xing, Lu
    SUSTAINABLE CITIES AND SOCIETY, 2019, 46
  • [28] Economic assessment and regional adaptability analysis of CCHP system coupled with biomass-gas based on year-round performance
    Zhang, Dong
    Zhang, Bin
    Zheng, Yu
    Zhang, Rui
    Liu, Pengfei
    An, Zhoujian
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 45
  • [29] Optimal design and analysis of CCHP system for a hotel application
    Li, Miao
    Qin, Chengwei
    Feng, Yiran
    Zhou, Maojun
    Mu, Hailin
    Li, Nan
    Ma, Qinyi
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 2329 - 2334
  • [30] Design Analysis of an Optimal Microgrid System for the Integration of Renewable Energy Sources at a University Campus
    AlKassem, Abdulrahman
    Draou, Azeddine
    Alamri, Abdullah
    Alharbi, Hisham
    SUSTAINABILITY, 2022, 14 (07)