Parallel and non-parallel cannulated screw fixation complications in femoral neck fractures: A systematic review and meta-analysis

被引:4
|
作者
Lim, Eic Ju [1 ]
Kim, Beom-Su [2 ]
Kim, Chul-Ho [3 ]
机构
[1] Chungbuk Natl Univ, Dept Orthopaed Surg, Chungbuk Natl Univ Hosp, Coll Med, Cheongju, South Korea
[2] Gachon Univ, Dept Orthopaed Surg, Gil Med Ctr, Incheon, South Korea
[3] Chung Ang Univ, Dept Orthopaed Surg, Chung Ang Univ Hosp, Coll Med, 102 Heukseok Ro, Seoul 06973, South Korea
关键词
Multiple cannulated screw; Femoral neck fracture; Parallel; Non-parallel; Diverge; Cross; Meta-analysis; INTRACAPSULAR FRACTURES; FEMUR;
D O I
10.1016/j.otsr.2021.103005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Since its introduction in the early 1960s, the multiple cannulated screw fixation method has been developed for use in femoral neck fractures (FNFs); however, the parallelism of screws remains controversial. Materials and methods: MEDLINE, Embase, and the Cochrane Library were systematically searched for studies published before June 2, 2020, that compared the use of parallel and non-parallel screw fixation for the treatment of FNF. The pooled analysis was designed to identify differences between the two groups and focused on postoperative complications, including fracture nonunion and osteonecrosis of the femoral head (ONFH). Results: Over four studies, we enrolled 445 patients, including 195 patients with fixed FNF with parallel trajectory screws and 250 patients with fixed FNF with non-parallel screws. The pooled analysis showed no difference in the nonunion rates (odds ratio (OR) = 0.91; 95% confidence interval (CI), 0.24-3.44; p = 0.89) and no significant difference in the incidence of ONFH between parallel and non-parallel screw fixation (OR = 0.74; 95% CI: 0.21-2.63; p = 0.64). Conclusions: The results of this meta-analysis reveal that screw parallelism in multiple cannulated screw fixation of FNF has no relationship with either the fracture nonunion rate or the incidence of postoperative ONFH. Level of evidence: III; meta-analysis. (c) 2021 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Computer-assisted cannulated screw internal fixation versus conventional cannulated screw internal fixation for femoral neck fractures: a systematic review and meta-analysis
    Qing-hao Cheng
    Peng-biao Li
    Ting-ting Lu
    Shi-fang Guo
    Wen-fei Di
    Ke-hu Yang
    Yao-wen Qian
    Journal of Orthopaedic Surgery and Research, 16
  • [2] Computer-assisted cannulated screw internal fixation versus conventional cannulated screw internal fixation for femoral neck fractures: a systematic review and meta-analysis
    Cheng, Qing-Hao
    Li, Peng-Biao
    Lu, Ting-Ting
    Guo, Shi-Fang
    Di, Wen-Fei
    Yang, Ke-Hu
    Qian, Yao-Wen
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [3] Fixation of femoral neck fractures using divergent versus parallel cannulated screws
    Papanastassiou I.D.
    Mavrogenis A.F.
    Kokkalis Z.T.
    Nikolopoulos K.
    Skourtas K.
    Papagelopoulos P.J.
    Journal of Long-Term Effects of Medical Implants, 2011, 21 (01) : 63 - 69
  • [4] Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation
    Nikolai Ramadanov
    Ionel Toma
    Harald Herkner
    Roman Klein
    Wilhelm Behringer
    Gerrit Matthes
    Scientific Reports, 10
  • [5] Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation
    Ramadanov, Nikolai
    Toma, Ionel
    Herkner, Harald
    Klein, Roman
    Behringer, Wilhelm
    Matthes, Gerrit
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [6] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiang, Jiabao
    Chen, Jialei
    Xing, Fei
    Liu, Hao
    Xiang, Zhou
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [7] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiabao Jiang
    Jialei Chen
    Fei Xing
    Hao Liu
    Zhou Xiang
    BMC Musculoskeletal Disorders, 24
  • [8] Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis
    Xia, Yutong
    Zhang, Wendong
    Zhang, Zhen
    Wang, Jingcheng
    Yan, Lianqi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [9] Robot-assisted vs freehand cannulated screw placement in femoral neck fractures surgery A systematic review and meta-analysis
    Zheng, Yongshun
    Yang, Jiazhao
    Zhang, Fan
    Lu, Jinsen
    Qian, Yeben
    MEDICINE, 2021, 100 (20) : E25926
  • [10] The value of washers in cannulated screw fixation of femoral neck fractures
    Zlowodzki, M
    Weening, B
    Petrisor, B
    Bhandari, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04): : 969 - 975