Spinal Cord Stimulation and the Pregnant Patient-Specific Considerations for Management: A Case Series and Review of the Literature

被引:26
作者
Bernardini, Donald J. [1 ]
Pratt, Stephen D. [1 ]
Takoudes, Tamara C. [2 ]
Simopoulos, Thomas T. [1 ]
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Obstet & Gynecol,Div Maternal & Fetal Med, Boston, MA 02215 USA
来源
NEUROMODULATION | 2010年 / 13卷 / 04期
关键词
Electromagnetic fields; obstetric and anesthetic considerations; pregnancy; rechargeable implantable pulse generators; spinal cord stimulation; DEVELOPMENTAL TOXICITY; MAGNETIC-FIELDS; BLOOD-FLOW; LABOR; WOMAN; REPRODUCTION; EXPOSURE; GROWTH;
D O I
10.1111/j.1525-1403.2010.00288.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives: The use of spinal cord stimulation (SCS) is a form of neuromodulation used to treat chronic pain in those patients who are refractory to conventional medical management. Not uncommonly, SCS can dramatically improve a patient's quality of life, and those who are in the childbearing years may go on to become pregnant. The purpose of this case series is to describe: 1) implantation considerations in women of childbearing age; 2) use of rechargeable systems; 3) the obstetric and anesthetic concerns in patients with spinal cord stimulators; 4) risks of using SCS in the peripartum period. Materials and Methods: Two female patients with complex regional pain syndrome I (CRPS I) who were well managed with SCS became pregnant. In both patients, the leads were placed through the T12/L1 interspace and the generator was placed in the buttock region. In the first patient, the device was deactivated prior to conception and maintained off for the duration of the pregnancy. The second patient became pregnant on two separate occasions, with active SCS for a portion of the first trimester. During her second pregnancy, the patient elected to use of SCS at 30 weeks' gestation. Results: The developing fetuses with intrauterine exposure to SCS were followed out for a minimum of two years and are developmentally normal. The physical presence of the device did not complicate obstetric or anesthetic care. Rechargeable SCS systems were not adversely affected when turned off for the duration of the pregnancy. Conclusion: Implantation of SCS devices in women of childbearing years should take into account the future needs of both obstetric and anesthetic care by avoiding the abdomen and lower lumbar spine whenever possible. There was no appreciable decline of battery capacity in present day constant current rechargeable generators when deactivated for the duration of pregnancy.
引用
收藏
页码:270 / 274
页数:5
相关论文
共 39 条
[1]  
*ADV NEUR SYST, 2008, EON NEUR SYST CLIN M
[2]  
Brent RL, 1999, TERATOLOGY, V59, P261
[3]   Mechanism of parturition and preterm tabor [J].
Challis, JRG .
OBSTETRICAL & GYNECOLOGICAL SURVEY, 2000, 55 (10) :650-660
[4]   Developmental toxicity evaluation of ELF magnetic fields in Sprague-Dawley rats [J].
Chung, MK ;
Kim, JC ;
Myung, SH ;
Lee, DI .
BIOELECTROMAGNETICS, 2003, 24 (04) :231-240
[5]  
CUNNINGHAM FG, 2005, INTRAPARTUM ASSESSME, P443
[6]  
DATTA S, 2009, CAUDAL ANESTHESIA OB, P166
[7]   Complications of spinal cord stimulation: Identification, treatment, and prevention [J].
Deer, Timothy R. ;
Stewart, C. Douglas .
PAIN MEDICINE, 2008, 9 :S93-S101
[8]   Accidental electric shock in pregnancy: A prospective cohort study [J].
Einarson, A ;
Bailey, B ;
Inocencion, G ;
Ormond, K ;
Koren, G .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 176 (03) :678-681
[9]   The impact of repetitive transcranial magnetic stimulation on pituitary hormone levels and cortisol in healthy subjects [J].
Evers, S ;
Hengst, K ;
Pecuch, PW .
JOURNAL OF AFFECTIVE DISORDERS, 2001, 66 (01) :83-88
[10]   Labor epidural placement in a woman with a cervical spinal cord stimulator [J].
Hanson, J. L. ;
Goodman, E. J. .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2006, 15 (03) :246-249