Evaluation of PAMAM Dendrimers (G3, G4, and G5) in the Construction of a SPR-based Immunosensor for Cardiac Troponin T

被引:12
作者
Giarola, Juliana de F. [1 ,2 ]
Souto, Denio E. P. [3 ]
Kubota, Lauro T. [1 ,2 ]
机构
[1] Univ Campinas UNICAMP, Inst Chem, BR-13083970 Campinas, SP, Brazil
[2] Natl Inst Sci & Technol Bioanalyt INCTBio, Campinas, SP, Brazil
[3] Fed Univ Parana UFPR, Dept Chem, BR-81530900 Curitiba, Parana, Brazil
基金
巴西圣保罗研究基金会;
关键词
Surface plasmon resonance; immunosensor; PAMAM dendrimer; acute myocardial infarction; cardiac troponin T; MYOCARDIAL-INFARCTION; ELECTROCHEMICAL IMMUNOSENSOR; BIOSENSORS; ELECTRODES; ANTIBODIES; REAGENT;
D O I
10.2116/analsci.20P394
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunosensor was developed using a SAM of an alkanethiol associated with PAMAM(G4) dendrimers based on surface plasmon resonance (SPR) to enhance the sensitivity for troponin T detection in blood samples. The feasibility of using three-dimensional platforms based on dendrimers for the development of immunosensors was demonstrated by evaluating three different generations of these dendrimers (G3, G4, and G5) to detect troponin T. The results showed the efficiency of these 3D platforms in anchoring biomolecules, amplifying the detection of troponin T. The sandwich assay showed good performance for troponin T detection, using secondary monoclonal antibodies, in the concentration range of 5 - 300 ng mL(-1) (0.14 - 8.67 nmol L-1), R-2 = 0.991, with the LOD of 3.6 ng mL(-1). The sandwich assay's applicability was demonstrated by evaluating a secondary polyclonal antibody's performance in the concentration range of 3 - 30 ng mL(-1), R-2 = 0.998, with the LOD of 0.98 ng mL(-1). The immunosensor was applied to determine troponin T in blood plasma samples from healthy patients, with an average recovery of 88 to 104%. The performance of the SPR-based immunosensor indicates reliable results and is expected to contribute to the rapid diagnosis of heart attack, with reduced costs.
引用
收藏
页码:1007 / 1013
页数:7
相关论文
共 49 条
[1]  
Abbas A. K., 2008, IMUNOLOGIA CELULAR M, V6th, P564
[2]  
Abd-Rabboh H. S. M., 2020, ANAL SCI, V36, P1359
[3]   Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor [J].
Akter, Rashida ;
Jeong, Bongjin ;
Lee, Yong-Mi ;
Choi, Jong-Soon ;
Rahman, Md. Aminur .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :637-643
[4]   Cardiovascular disease detection using bio-sensing techniques [J].
Altintas, Zeynep ;
Fakanya, Wellington M. ;
Tothill, Ibtisam E. .
TALANTA, 2014, 128 :177-186
[5]   Surface plasmon resonance based immunosensor for the detection of the cancer biomarker carcinoembryonic antigen [J].
Altintas, Zeynep ;
Uludag, Yildiz ;
Gurbuz, Yasar ;
Tothill, Ibtisam E. .
TALANTA, 2011, 86 :377-383
[6]  
[Anonymous], Cardiovascular Disease
[7]   Paper-based colorimetric spot test utilizing smartphone sensing for detection of biomarkers [J].
Aydindogan, Eda ;
Ceylan, Ayse Elcin ;
Timur, Suna .
TALANTA, 2020, 208
[8]   Electrochemical Immunosensor for Detection of Aflatoxin B1 Based on Indirect Competitive ELISA [J].
Azri, Farah Asilah ;
Sukor, Rashidah ;
Selamat, Jinap ;
Abu Bakar, Fatimah ;
Yusof, Nor Azah ;
Hajian, Reza .
TOXINS, 2018, 10 (05)
[9]   Poly(amidoamine) (PAMAM): An emerging material for electrochemical bio(sensing) applications [J].
Bahadir, Elif Burcu ;
Sezginturk, Mustafa Kemal .
TALANTA, 2016, 148 :427-438
[10]   Recent progress on the sensitive detection of cardiovascular disease markers by electrochemical-based biosensors [J].
Bakirhan, Nurgul K. ;
Ozcelikay, Goksu ;
Ozkan, Sibel A. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 :406-424