MR/CT image fusion of the spine after spondylodesis: a feasibility study

被引:13
作者
Karlo, C. A. [1 ,2 ]
Steurer-Dober, I. [2 ,3 ]
Leonardi, M. [4 ]
Pfirrmann, C. W. A. [2 ]
Zanetti, M. [2 ]
Hodler, J. [2 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Hosp Balgrist, Dept Radiol, CH-8008 Zurich, Switzerland
[3] Kantonsspital Luzern, Inst Radiol, CH-6000 Luzern, Switzerland
[4] Univ Hosp Balgrist, Dept Orthoped Surg, CH-8008 Zurich, Switzerland
关键词
Image fusion; MRI; CT; Lumbar spine; Spondylodesis; OPEN-SOURCE SOFTWARE; FDG PET; CT; MR; ANGIOGRAPHY; INTEGRATION; EXPERIENCE; OSIRIX; TUMORS; SPECT;
D O I
10.1007/s00586-010-1430-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of this study is to evaluate feasibility, accuracy and time requirements of MR/CT image fusion of the lumbar spine after spondylodesis. Sagittal MR and CT images derived from standard imaging protocols (sagittal T2-weighted MR/sagittal reformatted multi-planar-reformation of the CT) of the lumbar spine with correct (n = 5) and incorrect (n = 5) implant position were fused by two readers (R1, R2) using OsiriX in two sessions placing one (session 1) or two (session 2) reference point(s) on the dorsal tip(s) of the cranial and caudal endplates from the second lumbar to the first sacral vertebra. R1 was an experienced musculoskeletal radiologist; R2 a spine surgeon, both had received a short training on the software tool. Fusion times and fusion accuracy, defined as the largest deviation between MR and CT in the median sagittal plane on the ventral tip of the cranial end plate of the most cranial vertebra visible on the CT, were measured in both sessions. Correct or incorrect implant position was evaluated upon the fused images for all patients by an experienced senior staff musculoskeletal radiologist. Mean fusion time (session 1/session 2; in seconds) was 100.4/95 (R1) and 104.2/119.8 (R2). Mean fusion deviation (session 1/session 2; in mm) was 1.24/2.20 (R1) and 0.79/1.62 (R2). The correct/incorrect implant position was identified correctly in all cases. In conclusion, MR/CT image fusion of the spine with metallic implants is feasible, fast, accurate and easy to implement in daily routine work.
引用
收藏
页码:1771 / 1775
页数:5
相关论文
共 22 条
[1]   Three-dimensional reconstruction and fusion for multi-modality spinal images [J].
Chen, YT ;
Wang, MS .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2004, 28 (1-2) :21-31
[2]   Evaluating commercial image registration packages for radiotherapy treatment planning [J].
Dalah, Entesar Z. ;
Nisbet, A. ;
Reise, S. ;
Bradley, D. .
APPLIED RADIATION AND ISOTOPES, 2008, 66 (12) :1948-1953
[3]   Cardiac PET-CT [J].
Di Carli, Marcelo F. ;
Dorbala, Sharmila .
JOURNAL OF THORACIC IMAGING, 2007, 22 (01) :101-106
[4]   Integration of Three-Dimensional Scar Maps for Ventricular Tachycardia Ablation With Positron Emission Tomography-Computed Tomography [J].
Dickfeld, Timm ;
Lei, Peng ;
Dilsizian, Vasken ;
Jeudy, Jean ;
Dong, Jun ;
Voudouris, Apostolos ;
Peters, Robert ;
Saba, Magdi ;
Shekhar, Raj ;
Shorofsky, Stephen .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (01) :73-82
[5]   Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography [J].
Gaemperli, Oliver ;
Schepis, Tiziano ;
Kalff, Victor ;
Namdar, Mehdi ;
Valenta, Ines ;
Stefani, Laurent ;
Desbiolles, Lotus ;
Leschka, Sebastian ;
Husmann, Lars ;
Alkadhi, Hatem ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (07) :1097-1106
[6]   Cardiac image fusion from stand-alone SPECT and CT: Clinical experience [J].
Gaemperli, Oliver ;
Schepis, Tiziano ;
Valenta, Ines ;
Husmann, Lars ;
Scheffel, Hans ;
Duerst, Victor ;
Eberli, Franz R. ;
Luscher, Thomas F. ;
Alkadhi, Hatem ;
Kaufmann, Philipp A. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) :696-703
[7]   Osirix: Free and open-source software for medical imagery [J].
Jalbert, F. ;
Paoli, J. R. .
REVUE DE STOMATOLOGIE ET DE CHIRURGIE MAXILLO-FACIALE, 2008, 109 (01) :53-55
[8]   Multisegmental image fusion of the spine [J].
Kaminsky, J ;
Rodt, T ;
Zajaczek, J ;
Donnerstag, F ;
Zumkeller, M .
BIOMEDIZINISCHE TECHNIK, 2004, 49 (03) :49-55
[9]   A 3-D model-based registration approach for the PET, MR and MCG cardiac data fusion [J].
Mäkelä, T ;
Pham, QC ;
Clarysee, P ;
Nenonen, J ;
Lötjönen, J ;
Sipilä, O ;
Hänninen, H ;
Lauerma, K ;
Knuti, J ;
Katila, T ;
Magnin, IE .
MEDICAL IMAGE ANALYSIS, 2003, 7 (03) :377-389
[10]   Neuronavigational guidance in craniofacial approaches for large (para)nasal tumors involving the anterior skull base and upper clival lesions [J].
Nakamura, M. ;
Stoever, T. ;
Rodt, T. ;
Majdani, O. ;
Lorenz, M. ;
Lenarz, T. ;
Krauss, J. K. .
EJSO, 2009, 35 (06) :666-672