Worldwide clinical experience with a new dual-chamber implantable cardioverter defibrillator system

被引:55
作者
Schoels, W
Swerdlow, CD
Jung, W
Stein, KM
Seidl, K
Haffajee, CJ
机构
[1] Univ Heidelberg, Dept Cardiol, D-69115 Heidelberg, Germany
[2] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[3] Univ Bonn, Dept Cardiol, D-5300 Bonn, Germany
[4] Cornell Univ, Coll Med, New York, NY USA
[5] Heart Ctr Ludwigshafen, Ludwigshafen, Germany
[6] St Elizabeths Med Ctr, Boston, MA USA
关键词
implantable cardioverter defibrillator; ventricular tachyarrhythmias; atrial fibrillation;
D O I
10.1046/j.1540-8167.2001.00521.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
New Dual-Chamber ICD. Introduction: Management of atrial tachyarrhythmias represents a significant challenge in patients with implantable cardioverter defibrillators (ICDs). Drug therapy of these arrhythmias is limited by moderate efficacy, ventricular proarrhythmia, and drug-device interactions. This study tested the safety and efficacy of a new dual-chamber ICD to detect and treat atrial as well as ventricular tachyarrhythmias, Methods and Results: A dual-chamber ICD (Medtronic 7250 Jewel AF) was implanted in 293 of 303 patients at 49 centers in Europe, Canada, and North America. Specific data were collected at implant and during a mean follow-up period of 7.9 +/- 4.7 months. There were no clinically evident failures to detect and treat ventricular arrhythmias. In patients with at least one of the dual-chamber detection criteria activated, 1,056 of 1,192 episodes of ventricular tachycardia or fibrillation detected were judged to be appropriate (89 % positive predictive accuracy). Therapy efficacy was 100 % in the ventricular fibrillation zone and 98 % in the ventricular tachycardia zone. Positive predictive accuracy for detection of atrial episodes was 95 % (1,052/1,107), For episodes classified as atrial tachycardia by the device, the efficacy of atrial antitachycardia pacing and high-frequency (50-Hz) burst pacing was 55% and 17%, respectively. High-frequency burst pacing terminated 16.8% of episodes classified as atrial fibrillation, and atrial defibrillation had an estimated efficacy of 76 %. The actuarial estimates of 6-month complication-free survival and total survival were 88 % and 94 %, respectively. Conclusion: This novel dual-chamber ICD is capable of safely and effectively discriminating atrial from ventricular tachyarrhythmias and of treating atrial tachyarrhythmias without compromising detection and treatment of ventricular tachyarrhythmias.
引用
收藏
页码:521 / 528
页数:8
相关论文
共 23 条
[1]   Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator [J].
Bardy, GH ;
Yee, R ;
Jung, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (02) :400-410
[2]   The potential usage of dual chamber pacing in patients with implantable cardioverter defibrillators [J].
Best, PJM ;
Hayes, DL ;
Stanton, MS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01) :79-85
[3]   RESULTS AND REALISTIC EXPECTATIONS WITH TRANSVENOUS LEAD SYSTEMS [J].
BLOCK, M ;
HAMMEL, D ;
ISBRUCH, F ;
BORGGREFE, M ;
WIETHOLT, D ;
HACHENBERG, T ;
SCHELD, HH ;
BREITHARDT, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (04) :665-670
[4]  
Cappato R, 1999, AM J CARDIOL, V83, p68D
[5]   Interactions between antiarrhythmic drugs and implantable cardioverter defibrillators [J].
Dougherty, AH .
CURRENT OPINION IN CARDIOLOGY, 1996, 11 (01) :2-8
[6]   Effects of High-Frequency Atrial Pacing in Atypical Atrial Flutter and Atrial Fibrillation [J].
Giorgberidze I. ;
Saksena S. ;
Mongeon L. ;
Mehra R. ;
Krol R.B. ;
Munsif A.N. ;
Mathew P. .
Journal of Interventional Cardiac Electrophysiology, 1997, 1 (2) :111-123
[7]   NONTHORACOTOMY DEFIBRILLATOR IMPLANTATION - A SINGLE-CENTER EXPERIENCE WITH 200 PATIENTS [J].
HAMMEL, D ;
SCHELD, HH ;
BLOCK, M ;
BREITHARDT, G .
ANNALS OF THORACIC SURGERY, 1994, 58 (02) :321-327
[8]   Experience with pectoral versus abdominal implantation of a small defibrillator - A multicenter comparison in 778 patients [J].
Hoffmann, E ;
Steinbeck, G .
EUROPEAN HEART JOURNAL, 1998, 19 (07) :1085-1098
[9]   STANDARDIZED REPORTING OF ICD PATIENT OUTCOME - THE REPORT OF A NORTH-AMERICAN SOCIETY-OF-PACING-AND-ELECTROPHYSIOLOGY POLICY CONFERENCE, FEBRUARY 9-10, 1993 [J].
KIM, SG ;
FOGOROS, RN ;
FURMAN, S ;
CONNOLLY, SJ ;
KUCK, KH ;
MOSS, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (07) :1358-1362
[10]   INCIDENCE OF ICD LEAD RELATED COMPLICATIONS DURING LONG-TERM FOLLOW-UP - COMPARISON OF EPICARDIAL AND ENDOCARDIAL ELECTRODE SYSTEMS [J].
KORTE, T ;
JUNG, W ;
SPEHL, S ;
WOLPERT, C ;
MOOSDORF, R ;
MANZ, M ;
LUDERITZ, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (11) :2053-2061