Pelvic Nodal Dosing With Registration to the Prostate: Implications for High-Risk Prostate Cancer Patients Receiving Stereotactic Body Radiation Therapy

被引:14
作者
Kishan, Amar U. [1 ]
Lamb, James M. [1 ]
Jani, Shyam S. [1 ]
Kang, Jung J. [1 ]
Steinberg, Michael L. [1 ]
King, Christopher R. [1 ]
机构
[1] UCLA, David Geffen Sch Med, Dept Radiat Oncol, Los Angeles, CA 90095 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2015年 / 91卷 / 04期
关键词
INTENSITY-MODULATED RADIOTHERAPY; LYMPH-NODES; ONCOLOGY GROUP-9413; RECTAL-CANCER; BONY ANATOMY; IRRADIATION; MARKERS; LOCALIZATION; FEASIBILITY; MOTION;
D O I
10.1016/j.ijrobp.2014.11.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine whether image guidance with rigid registration (RR) to intra-prostatic markers (IPMs) yields acceptable coverage of the pelvic lymph nodes in the context of a stereotactic body radiation therapy (SBRT) regimen. Methods and Materials: Four to seven kilovoltage cone-beam CTs (CBCTs) from 12 patients with high-risk prostate cancer were analyzed, allowing approximation of an SBRT regimen. The nodal clinical target volume (CTVN) and bladder were contoured on all kilovoltage CBCTs. The V-100 CTVN, expressed as a ratio to the same parameter on the initial plan, and the magnitude of translational shift between RR to the IPMs versus RR to the pelvic bones, were computed. The ability of a multimodality bladder filling protocol to minimize bladder height variation was assessed in a separate cohort of 4 patients. Results: Sixty-five CBCTs were assessed. The average V-100 CTVN was 92.6%, but for a subset of 3 patients the average was 80.0%, compared with 97.8% for the others (P<.0001). The average overall and superior-inferior axis magnitudes of the bony-to-fiducial translations were significantly larger in the subgroup with suboptimal nodal coverage (8.1 vs 3.9 mm and 5.8 vs 2.4 mm, respectively; P<.0001). Relative bladder height changes were also significantly larger in the subgroup with suboptimal nodal coverage (42.9% vs 18.5%; P<.05). Use of a multimodality bladder-filling protocol minimized bladder height variation (P<.001). Conclusion: A majority of patients had acceptable nodal coverage after RR to IPMs, even when approximating SBRT. However, a subset of patients had suboptimal nodal coverage. These patients had large bony-to-fiducial translations and large variations in bladder height. Nodal coverage should be excellent if the superior-inferior axis bony-to-fiducial translation and the relative bladder height change (both easily measured on CBCT) are kept to a minimum. Implementation of a strict bladder filling protocol may achieve this goal. (C) 2015 Elsevier Inc.
引用
收藏
页码:832 / 839
页数:8
相关论文
共 30 条
[1]   WHOLE PELVIC RADIOTHERAPY VERSUS PROSTATE ONLY RADIOTHERAPY IN THE MANAGEMENT OF LOCALLY ADVANCED OR AGGRESSIVE PROSTATE ADENOCARCINOMA [J].
Aizer, Ayal A. ;
Yu, James B. ;
McKeon, Anne M. ;
Decker, Roy H. ;
Colberg, John W. ;
Peschel, Richard E. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05) :1344-1349
[2]   Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate [J].
Alasti, H ;
Petric, MP ;
Catton, CN ;
Warde, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :869-884
[3]   IMRT significantly reduces acute toxicity of whole-pelvis irradiation in patients treated with post-operative adjuvant or salvage radiotherapy after radical prostatectomy [J].
Alongi, Filippo ;
Fiorino, Claudio ;
Cozzarini, Cesare ;
Broggi, Sara ;
Perna, Lucia ;
Cattaneo, Giovanni Mauro ;
Calandrino, Riccardo ;
Di Muzio, Nadia .
RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) :207-212
[4]   Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[5]   Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods [J].
Beltran, Chris. ;
Herman, Michael G. ;
Davis, Brian J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01) :289-295
[6]  
Britton Keith R, 2005, Radiat Med, V23, P14
[7]   Long-term results of a randomized trial comparing preoperative short-course radiotherapy with preoperative conventionally fractionated chemoradiation for rectal cancer [J].
Bujko, K. ;
Nowacki, M. P. ;
Nasierowska-Guttmejer, A. ;
Michalski, W. ;
Bebenek, M. ;
Kryj, M. .
BRITISH JOURNAL OF SURGERY, 2006, 93 (10) :1215-1223
[8]   A review of prostate motion with considerations for the treatment of prostate cancer [J].
Byrne, TE .
MEDICAL DOSIMETRY, 2005, 30 (03) :155-161
[9]   Significant reduction of acute toxicity following pelvic irradiation with Helical Tomotherapy in patients with localized prostate cancer [J].
Cozzarini, Cesare ;
Fiorino, Claudio ;
Di Muzio, Nadia ;
Alongi, Filippo ;
Broggi, Sara ;
Cattaneo, Mauro ;
Montorsi, Francesco ;
Rigatti, Patrizio ;
Calandrino, Riccardo ;
Fazio, Ferruccio .
RADIOTHERAPY AND ONCOLOGY, 2007, 84 (02) :164-170
[10]   Intensity-modulated radiotherapy (IMRT) to prostate and pelvic nodes-is pelvic lymph node coverage adequate with fiducial-based image-guided radiotherapy? [J].
Eminowicz, G. ;
Dean, C. ;
Shoffren, O. ;
MacDougall, N. ;
Wells, P. ;
Muirhead, R. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1037)