Gamma-irradiation Sterilization in an Inert Environment: A Partial Solution

被引:33
作者
Berry, Daniel J. [2 ]
Currier, Barbara H. [1 ]
Mayor, Michael B. [1 ]
Collier, John P. [1 ]
机构
[1] Dartmouth Coll, Dartmouth Biomed Engn Ctr, Thayer Sch Engn, Hanover, NH 03755 USA
[2] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
关键词
MOLECULAR-WEIGHT POLYETHYLENE; CLINICAL-PERFORMANCE; OXIDATION; BEARINGS; IMPACT; KNEE;
D O I
10.1007/s11999-011-2150-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In the mid to late 1990s, to sterilize UHMWPE bearings, manufacturers changed from gamma-irradiation-in-air (gamma-air) sterilization, which initiated oxidation leading to bearing fatigue, to gamma-irradiation sterilization in an inert environment (gamma-inert). The change to gamma-inert sterilization reportedly prevented shelf oxidation before implantation but not in vivo oxidation. We asked: (1) Has the change to gamma-inert sterilization prevented shelf oxidation that led to early in vivo fatigue damage in gamma-air-sterilized tibial inserts? And (2) has the change to gamma-inert sterilization prevented the occurrence of fatigue secondary to in vivo oxidation? We rated 183 retrieved gamma-air- and 175 retrieved gamma-inert-sterilized tibial inserts for clinical fatigue damage and analyzed 132 gamma-air- and 174 gamma-inert-sterilized tibial inserts for oxidation by Fourier transform infrared spectroscopy. Oxidation led to decreased mechanical properties in shelf-aged gamma-air-sterilized tibial inserts. Barrier packaging prevented shelf oxidation in gamma-inert-sterilized tibial inserts. Gamma-air- and gamma-inert-sterilized inserts oxidized in vivo. Fatigue damage (delamination) occurred more frequently in inserts retrieved after longer time in vivo. Longer in vivo time correlated with higher oxidation and more accumulated cycles of use. Published oxidation projections suggest gamma-inert-sterilized tibial inserts would reach the critical oxidation for the onset of fatigue after 11 to 14 years in vivo. These retrievals appear to follow the projected oxidation trends. Frequency of fatigue damage increased with increasing oxidation. Fatigue of tibial inserts becomes more likely, especially in active patients, after more than a decade of good clinical performance.
引用
收藏
页码:1805 / 1813
页数:9
相关论文
共 14 条
[1]  
[Anonymous], 2010, F64810A ASTM
[2]  
ASTM, 2010, ASTM D 638-10
[3]  
ASTM Standard, 2006, F210206 ASTM
[4]  
Bargmann LS, 1999, CLIN ORTHOP RELAT R, P49
[5]   Impact of gamma sterilization on clinical performance of polyethylene in the knee [J].
Collier, JP ;
Sperling, DK ;
Currier, JH ;
Sutula, LC ;
Saum, KA ;
Mayor, MB .
JOURNAL OF ARTHROPLASTY, 1996, 11 (04) :377-389
[6]   Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components [J].
Costa, Luigi ;
Bracco, Pierangiola ;
Del Prever, Elena Maria Brach ;
Kurtz, Steven M. ;
Gallinaro, Paolo .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (01) :20-26
[7]   In vivo oxidation of γ-barrier-sterilized ultra-high-molecular-weight polyethylene bearings [J].
Currier, Barbara H. ;
Currier, John H. ;
Mayor, Michael B. ;
Lyford, Kimberly A. ;
Van Citters, Douglas W. ;
Collier, John P. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (05) :721-731
[8]   Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups [J].
Currier, Barbara H. ;
Currier, John H. ;
Mayor, Michael B. ;
Lyford, Kimberly A. ;
Collier, John P. ;
Van Citters, Douglas W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :2023-2029
[9]  
Currier BH, 1997, CLIN ORTHOP RELAT R, P111
[10]   RETRIEVAL ANALYSIS OF TOTAL KNEE PROSTHESES - A METHOD AND ITS APPLICATION TO 48 TOTAL CONDYLAR PROSTHESES [J].
HOOD, RW ;
WRIGHT, TM ;
BURSTEIN, AH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (05) :829-842