Interaction between Thermal Comfort, Indoor Air Quality and Ventilation Energy Consumption of Educational Buildings: A Comprehensive Review

被引:97
作者
Jia, Lin-Rui [1 ]
Han, Jie [1 ]
Chen, Xi [2 ]
Li, Qing-Yun [3 ]
Lee, Chi-Chung [1 ]
Fung, Yat-Hei [1 ]
机构
[1] Hong Kong Metropolitan Univ, Sch Sci & Technol, Hong Kong 999077, Peoples R China
[2] Chinese Univ Hong Kong, Dept Mech & Automat Engn, Hong Kong 999077, Peoples R China
[3] Lingnan Univ, Teaching & Learning Ctr, Hong Kong 999077, Peoples R China
关键词
thermal comfort; indoor air quality; ventilation energy consumption; educational buildings; CARBON-DIOXIDE CONCENTRATION; PRIMARY-SCHOOL CLASSROOMS; PREDICTED MEAN VOTE; ENVIRONMENTAL-QUALITY; UNIVERSITY CLASSROOMS; NATURAL VENTILATION; HYBRID VENTILATION; ELEMENTARY-SCHOOLS; BUILT ENVIRONMENT; CAMPUS CLASSROOMS;
D O I
10.3390/buildings11120591
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal comfort and indoor air quality (IAQ) of educational buildings can affect students' academic performance and well-being and are closely related to ventilation energy consumption. Demands of the indoor environmental quality within the classroom generally vary with the education levels and result in ventilation energy consumption accounting for a considerable proportion of the total energy use in bulk educational buildings. Its huge energy-saving potential is attracting worldwide attention from scholars and governments. Therefore, appropriate operation strategies of ventilation systems should be adopted to effectively reduce energy consumption without sacrificing thermal comfort and IAQ. However, the absence of relevant standards and guidelines for designing a quality classroom environment considering the special features of educational buildings remains an important research question. This study conducts a comprehensive review to determine research gaps and identify future directions for the interaction between thermal comfort, IAQ and ventilation energy consumption for educational buildings. The review results show that: (1) The thermal comfort prediction model should consider the influences of genders, ages and socioeconomic backgrounds; (2) The mixed-mode ventilation coupling the natural and mechanical approaches is preferred given its advantage of lower energy consumption and improved thermal comfort, but its control strategies need further exploration; (3) Optimizing passive design parameters of buildings (e.g., window to wall ratios, window orientations and sun shading installations) can significantly reduce the ventilation demands while maintaining indoor thermal comfort; (4) More studies are required for investigating thermal comfort in educational buildings during the heating period; and (5) IAQ of university buildings clearly requires further studies, especially on bacterial and fungal aerosol pollutants, for a more comprehensive assessment of the built environment.
引用
收藏
页数:30
相关论文
共 160 条
[1]   Thermal comfort evaluation in campus classrooms during room temperature adjustment corresponding to demand response [J].
Aghniaey, Sama ;
Lawrence, Thomas M. ;
Sharpton, Tara Nicole ;
Douglass, Samuel Paul ;
Oliver, Tucker ;
Sutter, Morgan .
BUILDING AND ENVIRONMENT, 2019, 148 :488-497
[2]   Comparison of indoor air quality in schools: Urban vs. Industrial 'oil & gas' zones in Kuwait [J].
Al-Hemoud, Ali ;
Al-Awadi, Layla ;
Al-Rashidi, Mufreh ;
Rahman, Khan Abdul ;
Al-Khayat, Ahmed ;
Behbehani, Weam .
BUILDING AND ENVIRONMENT, 2017, 122 :50-60
[3]   Impact of ventilation modes on carbon dioxide concentration levels in Kuwait classrooms [J].
Al-Rashidi, Khaled ;
Loveday, Dennis ;
Al-Mutawa, Nawaf .
ENERGY AND BUILDINGS, 2012, 47 :540-549
[4]   Assessment of indoor thermal environment in different prototypical school buildings in Jordan [J].
Ali, Hikmat H. ;
Al-Hashlamun, Rifqa .
ALEXANDRIA ENGINEERING JOURNAL, 2019, 58 (02) :699-711
[5]   Indoor environmental quality of classrooms in Southern European climate [J].
Almeida, Ricardo M. S. F. ;
de Freitas, Vasco Peixoto .
ENERGY AND BUILDINGS, 2014, 81 :127-140
[6]   Indoor and outdoor air quality: A university cafeteria as a case study [J].
Alves, Celia A. ;
Vicente, Estela D. ;
Evtyugina, Margarita ;
Vicente, Ana M. ;
Nunes, Teresa ;
Lucarelli, Franco ;
Calzolai, Giulia ;
Nava, Silvia ;
Calvo, Ana, I ;
del Blanco Alegre, Carlos ;
Oduber, Fernanda ;
Castro, Amaya ;
Fraile, Roberto .
ATMOSPHERIC POLLUTION RESEARCH, 2020, 11 (03) :531-544
[7]  
[Anonymous], 2005, WHO Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide, World Health Organization Regional Office for Europe
[8]   A field study on adaptive thermal comfort in Spanish primary classrooms during summer season [J].
Aparicio-Ruiz, Pablo ;
Barbadilla-Martin, Elena ;
Guadix, Jose ;
Munuzuri, Jesus .
BUILDING AND ENVIRONMENT, 2021, 203
[9]   The impact of glazing ratio and window configuration on occupants' comfort and energy demand: The case study of a school building in Eskisehir, Turkey [J].
Ashrafian, Touraj ;
Moazzen, Nazanin .
SUSTAINABLE CITIES AND SOCIETY, 2019, 47
[10]   Subjective and objective assessment of acoustical and overall environmental quality in secondary school classrooms [J].
Astolfi, Arianna ;
Pellerey, Franco .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 123 (01) :163-173