A superconducting magnet with the center field of 9.4 T is designed and fabricated for 400 MHz Nuclear Magnetic Resonance. Superconducting coil with NbTi/Cu superconducting wire is employed and cooled by re-condensed liquid helium and the magnet system with the clear-bore of 54 mm. The pulsed tube refrigerator with separated valve is employed to cool the magnet system. The superconducting magnet has an active shield with high pure copper shield to protect during quench of the shielding coil. The paper reports the electromagnetic design, and fabrication is detailed.